Abstract

The paper shows the method of determining the start-up curves of a steam boiler, which enables its faster start-up. Faster temperature changes cause thermal stress, especially in thick-walled boiler elements. Critical elements that limit the rate of change of working fluid units include drums, outlet chamber, injection chamber, fresh steam superheater of steam coolers, tees and valve casings, rotor and turbine casing. The walls of these elements have the thickest walls due to the high pressure values occurring in them during operation. Allowable changes in temperature and pressure during start-up and shut-down can be determined by the European Standard EN 12952-3. The article shows how the start-up curves of a steam boiler can be determined using the European Standard and the method proposed by the author. Calculation results show that the starting time of the analyzed block can be significantly shortened.

Details

Title
New start-up curves for a 200 MW steam boiler with natural circulation
Author
Dzierwa, Piotr
Section
Mathematical Modeling in the Energy and Industrial Processes
Publication year
2018
Publication date
2018
Publisher
EDP Sciences
ISSN
22747214
e-ISSN
2261236X
Source type
Conference Paper
Language of publication
English
ProQuest document ID
2140097173
Copyright
© 2018. This work is licensed under http://creativecommons.org/licenses/by/4.0 (the “License”). Notwithstanding the ProQuest Terms and conditions, you may use this content in accordance with the terms of the License.