Introduction
Ozone () has been widely documented as one of the most dangerous pollutants for plants (Wittig et al., 2009; Matyssek et al., 2012; Gerosa et al., 2015; Marzuoli et al., 2018). The deposition of on forest ecosystems has been extensively studied over the last 20 years with eddy covariance field campaigns (Padro, 1996; Cieslik, 1998; Lamaud et al., 2002; Mikkelsen et al., 2004; Gerosa et al., 2005, 2009a, b; Launiainen et al., 2013), which were made possible thanks also to the development of fast analyzers. Measurements carried out in the 1990s were usually short-term field campaigns, while more recent campaigns have extended the observation periods and therefore led to a better understanding of the processes controlling deposition (Mikkelsen et al., 2004; Gerosa et al., 2005; Fowler et al., 2009; Rannik et al., 2012; Zona et al., 2014; Fares et al., 2010, 2012, 2014; Clifton et al., 2017; Finco et al., 2017).
These studies highlighted that an important deposition pathway is represented by the uptake by trees through leaf stomata. The amount entering the stomata strongly depends on the environmental and physiological factors that drive stomata opening (Jarvis, 1976; Emberson et al., 2000), such as, for example, the soil water availability that is positively correlated to the stomatal flux (Gerosa et al., 2009a; Büker et al., 2012).
Ozone deposition pathways other than plant stomata are usually grouped as nonstomatal deposition, although they include merely physical dry deposition processes and chemical consumption processes due to ambient air chemistry. Among these processes, which still remain to be understood in depth, we find the thermal decomposition on dry surfaces (Cape et al., 2009), the deposition on wet surfaces (Fuentes et al., 1992; Altimir et al., 2004, 2006; Gerosa et al., 2009b), the deposition on soil (Stella et al., 2011), reactions stimulated by light (Coe et al., 1995; Fowler et al., 2001), chemical reactions with NO (Dorsey et al., 2004; Rummel et al., 2007; Pilegaard, 2001; Gerosa et al., 2009b) and chemical reactions with biogenic volatile organic compounds (BVOCs) (Fares et al., 2010; Goldstein et al., 2004).
Also, deposition dynamics below the forest canopy and their relationship with the above-canopy fluxes are still to be fully understood, since only a few studies have directly measured fluxes below the canopy. For example, Launiainen et al. (2013) and Fares et al. (2014) used these measurements to assess different deposition pathways and to validate deposition models, while Dorsey et al. (2004) also included the role of fluxes and soil NO emission in the flux dynamics. Moreover, Goldstein et al. (2004) and Wolfe et al. (2011) highlighted the potential importance of in-canopy reactions of with BVOCs for removal from the ecosystem and the formation of secondary organic aerosols (SOA).
There are only a few studies in the literature that have reported fluxes measured at more than two levels along a vertical profile above and within a forest canopy and, to our knowledge, none of these were made on a mature broadleaf forest.
For example, Dorsey at al. (2004) measured fluxes at three levels, two above and one below a Douglas fir canopy, and Foken et al. (2012) performed the same measurements at four levels in a Norway spruce forest, one above the canopy, one at the top of the canopy and two below the canopy.
On the contrary, vertical gradients of concentration have been investigated, especially for flux calculation above the canopy with the aerodynamic gradient technique (Kramm et al., 1991; Horvath et al., 1998; Mikklesen et al., 2000; Keronen et al., 2003). However, a small to high variability of the ozone concentration inside the canopy emerged in many studies (Fontan et al., 1992; Keronen et al., 2003; Utiyama et al., 2004; Gerosa et al., 2005), revealing that uncertainties in the drivers of these gradients inside the canopy still remain. Nevertheless these kinds of measurements are needed for modeling exercises as indicated, for example, by Walton et al. (1997), Ganzeveld et al. (2002) and Launiainen et al. (2013), who tested the model capability to reproduce the in-canopy profiles of the concentration of and other gasses.
The major aims of this study were (i) to contribute to the understanding of the diel dynamics of fluxes and concentration gradients at five levels above and within a mature broadleaf forest canopy, (ii) to assess the ozone sinks above and within the forest and in particular the amount of deposited on the different forest layers (upper canopy, lower canopy, understorey, forest floor), and (iii) to evaluate the role of the exchange on the deposition, both at the top of the canopy and at soil level.
This work reports data from a joint field campaign that took place in 2012 in the framework of the European FP7 project ECLAIRE (“Effects of Climate Change on Air Pollution Impacts and Response Strategies for European Ecosystems”) in the Po Valley (Italy), one of the most polluted areas in Europe. This campaign also included simultaneous flux measurements of volatile organic compounds (VOCs), particles and ammonia that have been reported in Acton et al. (2016) and Schallhart et al. (2016). To our knowledge, this is the first time that fluxes have been measured at five levels above and within a broadleaf forest with the eddy covariance technique. The detailed dataset of this campaign will allow future tests on the capability of existing deposition models to correctly predict the deposition dynamics on forest ecosystems. Moreover, these data could help multilayer canopy models (Ganzeveld et al., 2002, 2015) to separate the influence of ambient air chemistry vs. dry deposition on the observed fluxes, and in particular to characterize the in-canopy dynamics involving reactions with and VOCs.
Material and methods
Site characteristics
Measurements were performed at the Bosco Fontana reserve (451202 N, 104444 E; elevation 25 m a.s.l.) located in Marmirolo near Mantua, Italy. The measuring site is a mature mixed oak–hornbeam forest located in the middle of the Po Valley, one of the most polluted areas of Europe. The forest belongs to a 233 ha natural reserve classified as a Site of Communitarian Importance and Special Protection Zone (IT20B0011) and it is part of the Long-Term Environmental Research (LTER) network.
The upper canopy (dominant tree layer) is composed of the higher trees such as hornbeam (Carpinus betulus, 40.45 % of the total surface of the reserve), oak (Quercus robur, 17.09 %), red oak (Quercus rubra, 9.65 %) and Turkey oak (Quercus cerris, 7.06 %) (Dalponte et al., 2007). Some species (Acer campestre, Prunus avium, Fraxinus ornus and oxycarpa, Ulmus minor and Alnus glutinosa along the small streams) are present but they account for no more than 3 % of the total surface.
The lower canopy (dominated tree layer) is represented by the lower trees and it is composed of hazel (Corylus avellana), elder (Sambucus spp.), cornell (Cornus mas), hawthorn (Crataegus oxyacantha and monogyna) and chequers (Sorbus torminalis). A thick understorey mostly composed of butcher's broom (Ruscus aculeatus, L.) is also present.
The average height of the canopy is 26 m and the average single-sided leaf area index (LAI), measured by a canopy structure meter (LAI2000), was 2.28 m m, with a maximum value of 4.22 m m.
The soil is a Petrocalcic Palexeralf, loamy skeletal, mixed, mesic (Campanaro et al., 2007) according to the USDA classification. The soil depth is 1.5 m with a petrocalcic hardened layer between 0.80 and 1 m below the ground; this layer was formed after the gradual deepening of the water table.
The climatic characteristics are typical of the Po Valley, with humid and hot summers (Longo, 2004). The mean annual temperature is 13.2 C (period 1840–1997, Bellumé et al., 1998) and July is the hottest month (24.6 C).
Winds coming from east (E) and north-east (NE) are the most frequent, in particular in spring and summer.
Measuring infrastructure
A 40 m height scaffolding tower was built inside the natural reserve (451152.27 N, 104432.27 E), at a distance from the edge of the forest ranging between a minimum of 390 m in the south (S) direction and a maximum of 1440 m in the NE direction.
The infrastructure was equipped with instrumentation for four different kinds of measurements: fluxes of energy and matter (, , , ) with the eddy covariance technique, soil flux of and with dynamic chambers, vertical profiles of gas concentrations (, ) and air temperature and humidity, and additional meteorological and agrometeorological measurements (solar radiation, precipitations, soil temperature, soil heat fluxes and soil water content).
Eddy covariance measurements of matter and energy fluxes
Four sonic anemometers (see Table 1 for instrument models) were placed on the tower at four different heights: 16, 24, 32 and 41 m. A fifth one was installed at 5 m a.g.l. on a pole, 10 m away from the tower, in the west direction. At the top tower level an open-path infrared gas analyzer (Model 7500, LI-Cor, USA) was also installed to measure the concentrations of water vapor and carbon dioxide, and at each of the five sampling heights a fast instrument was installed to measure vertical fluxes.
Fast analyzers (Table 1) were based on the reaction between and a coumarine-47 target which has to be changed after some days because its sensitivity declines exponentially with time (Ermel et al., 2013). Three fast analyzers, two COFA (chemiluminescent ozone fast analyzer) and one ROFI (rapid ozone flux instrument), which broadly followed the design of the GFAS instrument developed by Güsten and Heinrich (1996), were equipped with a relatively big fan (about 100 L min), which resulted in fast consumption of the coumarin target. The other two instruments, a prototype developed by the National Oceanic and Atmospheric Administration (NOAA, Fast Response Ozone Monitor; Bauer et al., 2000) and the commercial Fast Ozone Sensor (FOS, Sextant, NZ), both made use of a small membrane pump (2.5 L min) and thus had a lower consumption of the coumarin targets compared to the other instruments. For this reason, the coumarin targets were changed every 5 days for the COFA and the ROFI and every 10 days for the FROM and the FOS. In both cases the coumarin targets were pre-conditioned just before use by exposing them to a concentration of 100 ppb of for 2 h.
Above-canopy fluxes of NO were measured at 32 m by means of a CLD780TR fast analyzer (Ecophysics, CH) based on the chemiluminescence reaction between and NO. The air to be analyzed was drawn from 32 m through a in. ID Teflon tube main line at 60 L min to the analyzer placed at the bottom of the tower. The analyzer was subsampling at 3 L min from the main sampling line. The CLD780TR was calibrated with an 80 ppb standard produced using a dilution system (LNI 6000x, S) and a standard NO cylinder (18 ppm), at the beginning of the experiment, and then weekly.
All the fast instruments and the sonic anemometers were sampled at 20 Hz through a customized LabVIEW (National Instruments, IRL) program and data were collected and stored in half-hourly files.
Instruments installed at each level of the tower and on the mast at 5 m a.g.l. In brackets the variable measured by each instrument and the manufacturer are indicated. ( is air temperature, RH is relative humidity, NR is net radiation, is pressure, Rain is precipitation, SWC is soil water content, SHF is soil heat flux.) The soil dynamic chamber system is described in the methodological part.
Level/ | Ultrasonic | Fast | Other fast | Slow sensors | |
---|---|---|---|---|---|
height | anemometers | analyzers | analyzers | ||
(m) | |||||
41 | USA1 | COFA | LI-COR 7500 | HMP45 | (, RH, Vaisala, FIN) |
(Metek, D) | (Ecometrics, I) | (, , Li-Cor, USA) | NR-lite | (NR, Kipp & Zonen, NL) | |
BF5 | (PAR, Delta-T Devices, UK) | ||||
PTB101B | (, Vaisala, FIN) | ||||
Rain gauge 52202 | (Rain, Campbell Scientific, USA) | ||||
32 | HS50 | ROFI | CLD780TR | HMP45 | (, RH, Vaisala, FIN) |
(Gill, UK) | (CEH, UK) | (NO, Ecophysics, CH) | |||
24 | Windmaster PRO | FROM | – | HMP45 | (, RH, Vaisala, FIN) |
(Gill, UK) | (NOAA, USA) | ||||
16 | Windmaster PRO | COFA | – | HMP45 | (, RH, Vaisala, FIN) |
(Gill, UK) | (Ecometrics, I) | ||||
11 | – | – | – | HMP45 | (, RH, Vaisala, FIN) |
5 | R2 | FOS | LI-COR 7500 | – | |
(Gill, UK) | (Sextant, NZ) | (, Li-Cor, USA) | |||
1.5 | – | – | – | PT100 | (, Campbell Scientific, USA) |
0.15 | – | – | – | PT100 (, Campbell Scientific, USA) | |
Soil | – | – | – | TDR mod 616 | (SWC, Campbell Scientific, USA) |
HFP01SC | (SHF, Hukseflux, NL) | ||||
PT100 | (, GMR Strumenti, I) | ||||
Soil dynamic chamber system | (IMK-IFU, D) |
Soil NO, and flux measurements
Fluxes and concentrations of NO, and at the soil–atmosphere interface were determined by use of a fully automated measuring system as described in detail elsewhere (Butterbach-Bahl et al., 1997; Gasche and Papen, 1999; Rosenkranz et al., 2006; Wu et al., 2010). Briefly, five dynamic measurement chambers and one dynamic reference chamber were installed at the site. Dimensions of the chambers were 0.5 m 0.5 m 0.15 m (length width height). In contrast to the measuring chambers, the reference chamber was sealed gastight against the soil surface using a plate made of Perspex. A 1 h resolution was chosen for flux measurements. Every chamber was closed and measured for 6 min, and before each sampling of a measuring chamber the reference chamber was sampled, resulting in a measuring cycle of 60 min. During sampling, the air from the chambers was sucked at a constant rate of 50 L min and transported via PTFE tubing (inner diameter: 10 mm, length 20 m) to the analyzers. NO and concentrations were determined using a chemiluminescence detector CLD 770 AL equipped with a photolytic converter (models CLD 770AL and PLC 760, Ecophysics, CH), and concentrations were determined using a UV analyzer (model TE49C, Thermo Environmental Instruments, USA). Corrections for initial concentrations of NO, and at the outlet of each chamber and calculation of fluxes of NO and was performed according to Butterbach-Bahl et al. (1997). Calibration of the chemiluminescence detector was performed weekly using 40 ppb NO in synthetic air produced by dilution of standard gas (4 ppm NO in ) with synthetic air (80 % , 20 % ) using a multigas calibrator (model 6100, Environics, USA). Efficiency of photolytic conversion of to NO was determined at least weekly as described in detail by Butterbach-Bahl et al. (1997).
Vertical profile of and concentrations and air temperature and humidity
A computer-driven system of Teflon tubes and solenoidal Teflon valves was used to characterize the vertical concentration profile of and above and within the canopy at six heights: 5, 8, 16, 24, 32 and 41 m. The air samples drawn through in. ID Teflon tubes (all of them 50 m long) from each level by a 30 L min pump were sequentially sent to a UV photometer (model 49C, Thermo Scientific, USA) and to a chemiluminescence analyzer (model 42C, Thermo Environmental Instruments, USA) lodged in an air-conditioned container at the bottom of the tower. Both analyzers were subsampling at 2 L min out of the ID sampling lines.
All the tubes were insulated and continuously purged. Each level was sampled for 4 min after a 1 min wait to let the analyzers stabilize and then concentration data were recorded as half-hourly averages with a customized LabVIEW program (National Instruments, USA).
The gradient analyzer was calibrated against a reference photometer before and after the field campaign and no significant deviation from the first calibration was observed. The analyzer was calibrated with the same procedure described above for the Ecophysics CLD780TR at the beginning of the experiment and then weekly.
Additional and concentrations at 0.15 m were also available from the soil chambers system previously described.
The concentrations at 5, 16, 24, 32 and 41 m were also used as absolute reference for the fast instruments all of which change sensitivity sufficiently fast to require constant calibration against a slow-response absolute instrument.
Five temperature and relative humidity probes (model HMP45, Vaisala, Finland) were installed, at the higher tower levels (16, 24, 32 and 41 m) and, additionally, at 11 m. All these probes were connected to a data logger (CR23x, Campbell Scientific, USA), sampled once per minute and stored as half-hourly averages. Two additional temperature sensors (PT100, Campbell Scientific, USA) were available at 1.5 m and 0.15 m a.g.l. and data were collected with the same personal computer used for the control of the dynamic chamber system.
Additional meteorological and agrometeorological measurements
On the top of the tower a net radiometer NR-lite (Kipp & Zonen, NL), a BF5 sunshine sensor for total and diffuse PAR (Delta-T Devices, UK), a PTB101B barometer (Vaisala, Finland) and a rain gauge (model 52202, Campbell Scientific, USA) were mounted.
Several soil probes were installed at a distance of 20 m from the bottom of the tower: four reflectometers for soil water content (model TDR 616, Campbell Scientific, USA), four soil heat flux plates (model HFP01SC, Hukseflux, NL) and four soil temperature probes (PT100, GMR Strumenti, I). All these sensors were connected to a data logger (CR13x, Campbell Scientific, USA), sampled with a 1 min resolution and data were stored as half-hourly averages.
Measuring period
The measuring campaign began on 12 June and ended 1 month later, on 11 July 2012. From 12 to 23 June three fast instruments (ROFI, FROM and one of the two COFA samplers) were all placed above the canopy at a height of 32 m in order to compare them and to characterize their performances (“intercomparison period”). The COFA installed at the top of the tower started its measurements on 12 June and was not moved to the 32 m level for the intercomparison because it was already compared with the second COFA before the campaign.
The intercomparison test allowed the agreement between the three instruments to be verified, and the average relative standard deviation was below 10 %. Considering the intrinsic variation due to the different behavior of individual coumarin targets no systematic correction was applied. The sextant analyzer, the one employed at 5 m, was calibrated after the field campaign against one of the two COFA. Also in this case, no significant deviation was observed and no corrections were applied.
On 24 June each fast instrument was moved to a different level (Table S1 in the Supplement) to begin the flux profile measurements, which ended on 11 July (“Flux Profile period”). Every average diel course showed in the results section is referred to this period.
The FOS installed at 5 m was checked after the field campaign by running it in parallel with the COFA previously used at 32 m in the intercomparison period.
Data processing
The flux measurement technique adopted here was the eddy covariance method (Foken, 2008), which states that fluxes are equal to the covariance between the vertical wind component and the scalar of interest (Arya, 2001). An averaging period of 30 min was chosen for the calculation of the covariances.
Despiking
The data series were divided into 2 min subseries and for each of them block average and standard deviation were calculated. Spikes were identified as the instantaneous data that exceeded the average of each subseries for more than 3.5 times the standard deviation, as proposed by Vickers and Mahrt (1997). Spikes were removed from the series and the data were then gap-filled by a linear interpolation.
Rotations
Two axis rotations were applied to the instantaneous wind components to align with the mean flow over the averaging period: the first rotation aligned the horizontal wind to the 30 min average component (this rotation forces ), and the second one to rotate the xy plane in order to zero the 30 min average vertical component of the wind () (McMillen, 1988; Wilczak et al., 2001). These rotations corrected the little imperfections in the vertical alignment of the sonic anemometers and prepare data for flux calculations. Samples with a second rotation (vertical tilt) angle greater than 15 were discarded.
Linear detrending
The fluctuations of each parameter (, , ) were calculated as the differences of each instantaneous value from the best linear fit (minimum square) of the considered time series during each half hour (Lee at al., 2004).
Time-lag determination
fluxes were calculated using a fixed time lag between the vertical wind time series and the concentration one. For each fast instrument the time lag that maximized the cross-covariance function between the vertical component of the wind and the concentrations was identified and the more frequent lag was used in the calculations for each half-hourly average flux.
Elimination of the kinematic fluxes below the error threshold
The error threshold was quantified for each half-hourly data series by following the methodology proposed by Langford et al. (2015). The standard deviation of the auto-correlation function was calculated for each half-hourly data chunk, with lags ranging between 30 and 60 s from the characteristic time lag of each instrument. Kinematic fluxes lower than 3 times the standard deviation (relating to the 95th percentile) were discarded.
Frequency loss correction
The frequency loss correction factors for the different fast analyzers were calculated using the experimental transfer function approach following the methodology proposed by Aubinet et al. (2000). This method considers the normalized cospectra for sensible heat as unaffected by frequency loss or, at most, affected by frequency loss that is negligible with respect to those related to the other considered scalar (, NO, ). The transfer function is calculated for each half-hourly average as the ratio between the normalized cospectra of (in our case) and the normalized cospectra of sensible heat, then fitted with a Gaussian-type function (Aubinet et al., 2001), and thus used to calculate a correction factor for each instrument. For further details, please refer to Aubinet et al. (2012).
Schotanus and WPL corrections
Fluxes of sensible heat (), latent heat (LE) and trace gases were corrected for air density fluctuations. The formulation adopted for the correction of was the one proposed by Schotanus et al. (1983) while the formulation used for LE and trace gases was the one proposed by Webb et al. (1980).
Calculation of fluxes in physical units
Fast concentration data (acquired as voltages) and fast NO concentration data (acquired as counts per second) required additional processing to calculate quantitative fluxes in physical units. First, for all the fast instruments the target zero (Muller et al., 2010) – i.e., the output voltage when concentration is 0 ppb – was identified for each coumarin target employed. Then the fluxes were calculated by the following equation (Muller et al., 2010): where is the covariance between the vertical wind component and the raw output voltage of the fast instrument, is the half-hourly average output voltage of the instrument, is the zero target (identified for the considered half hour; it represents an estimation of the voltage at zero concentration) and is the concentration measured by the reference analyzer averaged over the same period. The data of the 2 h following each target change were excluded in order to allow the target sensitivity to stabilize after the target installation.
Similarly, NO fluxes () were calculated using the following equation: where cps (counts per second) is the raw signal of the NO analyzer photomultiplier and the prime stands for variation around the mean, and is the sensitivity of the analyzer determined by calibration against standard gases. ranged from 10 000 to 12 000 cps mol m).
Ozone storage
fluxes measured by eddy covariance were corrected for the storage every half hour. The storage is the temporal variation of the vertical profile below the measuring point located at the height . It does not represent a true removal or production process, but only a temporary accumulation of in the air column below the measuring point or a temporary release out of the same air column. For a nonreactive tracer, the proof of it is that the storage integrated over a whole day is null. The calculation of the storage is necessary for a proper determination of the deposition processes.
The correction of the fluxes for the storage was made by means of the following equation (Rummel et al., 2007): where are the fluxes corrected by storage, are the measured fluxes obtained with the Eq. (1), and the second term on the right represents the storage term. For a reactive tracer like some of the stored gas may be destroyed by reaction with NO and potentially with VOCs before being re-released to the air space above, and thus Eq. (3) must be considered an approximation. A fully resolving 1-D chemistry and exchange model would be required to quantify the effect of chemistry on the storage term more fully.
Stationarity check
Finally, the stationarity of each half-hourly sample was verified following the methodology of Foken and Wichura (1996) and the nonstationary data were discarded.
(a) Average diel course of specific humidity () at the five levels; (b) average diel course of friction velocity () at the five levels. Vertical bars represent the standard error of the mean.
[Figure omitted. See PDF]
Results
Microclimate
Significant rainfall had cooled the air before the beginning of the field campaign so that air temperature increased significantly only during the first days and then remained stable (Fig. S1a in the Supplement). The average temperature at the top of the tower was 25.9 C, while the lowest average temperature (23.1 C) was recorded at 0.15 m. The maximum temperature during the whole period was 36.2 C, which was observed at the top of the canopy (24 m).
On average the minimum temperature was registered during the night, at around 03:00 LT (local solar time, always the same hereafter) (Fig. S1b) for the 11 and 24 m levels and 1 h later for all the other levels, with values ranging from 19 to 21 C. Two significant rainfall events occurred in the final part of the campaign, accounting for a total of 108 mm of rain, but these did not significantly affect the air temperature (Fig. S1a). In general, most of the days were sunny (only three days were partially cloudy) and humid, with nighttime peaks of relative humidity up to 80 % and diurnal minima around 40 %. Specific humidity ranged, on average, between 10 and 13 g kg (Fig. 1a). Below-canopy levels ( m) showed higher than the above-canopy levels early in the morning, at around 06:00 LT, and from 13:00 to 21:00 LT, while the top-crown level (24 m) showed the lowest values from 04:00 to 16:00 LT. Similar specific humidity values were registered for the above-canopy levels, with slightly higher values at 41 m.
The wind blew mostly from the E or the W directions, with about 50 % of the data in these directions (Fig. S1c), while the north and south directions accounted for 12 % of the data and the intermediate directions accounted for less than 20 % of the data. The diurnal wind intensity at 41 and 32 m was on average around 2 and 1.5 m s respectively (Fig. S1d), and the wind intensity was slightly greater during the night than during daytime, with nearly 1 m s more at 41 m and 0.5 m s at 32 m. The three lower levels showed very low intensity, below 0.5 m s, with only a minor increase during the day.
The friction velocity () at the two upper levels above the canopy showed a very similar behavior (Fig. 1b) but was slightly higher at 32 m ( %). Diel maxima of of about 0.5 m s occurred between 09:00 and 13:00 LT, followed by a prompt decrease of nearly 20 % and then a gradual decrease. The minimum (0.13 m s) was observed around 20:00 LT, while values between 0.2 and 0.3 m s were observed during the night. The in-canopy measurements of friction velocity at the lowest three levels were significantly lower than the above-canopy ones: 24 and 5 m measurements were less than 50 % of the two upper levels and 16 m measurements were around 70 % less than above-canopy levels. The diurnal maxima at noon were 0.25 m s at 24 m, 0.18 m s at 16 m and 0.26 m s at 5 m, and during the night the friction velocity showed an almost constant trend with values around 0.1 m s at 5 m and around 0.05 m s for the two other levels.
Profiles of temperature, heat fluxes and atmospheric stability
In the early morning hours after sunrise, the heating of the top part of the canopy developed a thermal inversion in the forest with the ceiling at the top of the canopy (level 24 m) and the base at ground level (Fig. 2a).
Above the canopy temperature gradients were strongly superadiabatic from 04:00 to 17:00 LT; however, it should be noted that heat transfer increased significantly only when friction velocity increased.
Diurnal evolution of vertical profile of air temperature. (a) From 0:00 to 06:00 LT; (b) from 08:00 to 18:00 LT. The green shaded area represents the vertical distribution of the leaf area density expressed as m m ( LAI).
[Figure omitted. See PDF]
During the morning, the gradual heating of the canopy reached the upper canopy layer, registering its maximum value at noon. As a consequence, the inversion ceiling was lowered to the bottom part of the tree crowns (16 m). But already from 14:00 LT the air layers in the middle of the trunk space started to cool and the inversion ceiling gradually reached the top of the canopy again. By 18:00 LT the top of the canopy had cooled sufficiently for the above-canopy atmosphere to become stable and remain in this condition until 04:00 LT (Fig. 2b).
The presence of an inside canopy thermal inversion is also confirmed by the measured sensible heat fluxes (Fig. 3). Above the canopy the heat fluxes were strongly directed upwards during the day. However, the sensible heat fluxes at 32 m were about 20 % larger than those at 41 m.
In the upper part of the crown (24 m), sensible heat fluxes were less than half the above-canopy ones in the central part of the day. On the contrary, the heat fluxes at 16 and 5 m were almost always zero or negative (directed downwards). In relation to the strengthening of the thermal inversion in the afternoon, it is worth noting that the downward heat fluxes peaked at 14:00 LT at 5 m, 2 h later at 16 m and 4 h later at 24 m.
However, the forest released most of the energy as latent heat, showing a peak of about 300 W m at midday and presenting very low values at nighttime.
Above the canopy, the atmosphere was nearly always unstable during the day, while below the canopy it was mostly stable, as shown in Fig. 4. At the top canopy level (24 m) the most frequent condition in the central hours of the day was strong instability because of the canopy heating due to radiation. Remarkably, stable conditions at this level strengthened from 15:00 to 19:00 LT only during the inversion.
Average diel course of sensible heat fluxes at the five levels (41, 32, 24, 16 and 5 m, thick lines) and latent heat flux at 41 m (dashed line). Vertical bars represent the standard error of the mean.
[Figure omitted. See PDF]
Inside the canopy (16 m), the atmosphere was mainly stable or very stable. In particular, from 14:00 to 19:00 LT the air inside canopy was almost always very stable, as also occurred in the morning from 06:00 to 08:00 LT. During the night, the atmosphere was mainly stable or very stable above the canopy, while at 24 and 16 m some nocturnal instability was observed; this instability might be due to numerical artifacts because the sensible heat fluxes were close to zero. A similar explanation can also be used for the stability class distribution at 5 m, for which some instability was observed. In any case, the stable condition was the most frequent situation observed at that level.
Stability class distributions in the different hours of the day expressed as function of for the different levels: (a) 41 m, (b) 32 m, (c) 24 m, (d) 16 m and (e) 5 m. is the measuring height while is the Obukhov length. The stability classes were classified as follows according to Gerosa et al. (2017): very stable: ; stable: ; neutral: ; unstable: ; very unstable: .
[Figure omitted. See PDF]
Ozone concentrations profiles
Ozone concentrations above the canopy (41 and 32 m) showed the typical bell-shaped diurnal pattern, with a maximum around 80 ppb at 14:00 LT and a minimum around 25 ppb at 04:00 LT (Fig. 5).
The concentrations decreased slightly along the canopy height ( % between 32 and 5 m), while there was a significant reduction near the ground ( % between 32 and 0.15 m). At ground level, average concentrations never exceeded 27 ppb. It is worth noting the second (relative) minimum observed at 16:00 LT at the lowest level; this minimum is in agreement with a slight reduction in the concentrations observed in the upper levels inside the canopy (from 5 to 24 m). These features can be better observed considering the vertical variations in Fig. S2a and b. During the night the in-canopy gradient of was negligible, but from early morning a negative gradient rapidly developed and remained almost constant (around 0.2 ppb m) during the daylight hours, except in the afternoon. The slope of this gradient increased in the afternoon: at 16:00 LT from 8 to 32 m (around 0.5 ppb m) and at 18:00 LT but only from 24 to 32 m (around 0.8 ppb m). Another peculiarity emerged from 13:00 to 15:30 LT, when the concentration just above the canopy (32 m) was on average higher (by 2.0 to 3.8 ppb) than above (41 m); moreover, in the same period, the 24 m concentration was also higher than the value measured at 41 m (assuming values from 1.2 to 2.5 ppb).
Ozone fluxes profile
Ozone fluxes were corrected for the storage in the air layers below each measuring point. The magnitude of these corrections was not negligible and they were higher in the morning and the evening (Fig. S3) when the air layers in the trunk space are refilling with and emptying of , respectively. Considering the whole 41 m height air column, the greatest storage correction was nearly nmol m s in the morning, while in the evening it was about nmol m s; the integrated value over the day was null.
Ozone fluxes showed a regular behavior with almost always negative values, except for some positive peaks during the night or during the transition between night and day, in particular at the lowest levels (Fig. S4a). The largest deposition flux was observed on 25 June at 24 m with 46 nmol m s, which is in agreement with a peak of evapotranspiration (Fig. S4b). The following 2 days, fluxes and LE fluxes were nearly 50 % lower.
The good agreement between fluxes and LE (water) fluxes (Fig. S4) suggested the important role of the stomatal activity in the removal process because stomatal opening can increase both transpiration and stomatal uptake.
Average diel courses of concentrations at six levels (41, 32, 24, 16, 5 and 0.15 m). Vertical bars represent the standard error of the mean.
[Figure omitted. See PDF]
In general, fluxes and LE fluxes seemed to be correlated, but there were some exceptions (e.g., on 3 and 4 July). The smallest fluxes were observed on 6 July during the rainfall events, after which the fluxes showed an increase (7 July) even if concentrations were lower. This could be attributed to the enhancement of evapotranspiration fluxes following an increase in soil water content, even though we cannot exclude an influence of the nonstomatal processes (e.g., the increase in NO emissions from soil, Fig. 7e).
The average diel course of fluxes (Fig. 6) showed the typical behavior at all levels with low nighttime values and the greatest deposition in the central hours of the day.
Ozone fluxes measured above the canopy (41 and 32 m) showed very good agreement, nearly overlapping during the day (Fig. 6). Both increased very rapidly in the morning and then stayed almost constant (between 8 and 10 nmol m s) from 09:00 to 16:00 LT, when they started to decrease. At 24 m, fluxes were not constant in the central part of the day, and they were on average 40 % greater than the above-canopy levels, with average peaks around 15 nmol m s (Fig. 6). From 09:00 to 16:00 LT, air layers above the canopy including the top of the crown (from 24 m to the top of the tower) seemed decoupled from the air below: the above-canopy layers were in superadiabatic conditions with intense air mixing (Fig. 4a and b) while the below-canopy layer experienced a thermal inversion that gradually expands towards the top of the canopy and even above after 16:00 LT (Fig. 2b).
The greater fluxes at 24 m might be due to the location of these measurements, which are just in the transient region between well-mixed superadiabatic air and the below-canopy thermal inversion.
Average diel courses of fluxes at five levels (41, 32, 24, 16 and 5 m). Dots represent half-hourly averages while lines are 1.5 h running means centered on each half hour. Vertical bars represent the standard error of the mean.
[Figure omitted. See PDF]
NO and fluxes and concentrations
NO and concentrations along the tower profile (excluding near-ground measurements at 0.15 m) were relatively low with maximum values early in the morning of around 2 ppb for NO and around 14 ppb for . Neither NO nor concentrations showed great differences along the vertical profile (Fig. 7a and b). The greatest differences between the bottom and top level were only around 1 ppb for both compounds, during the early morning hours, between 04:00 and 09:00 LT.
At soil level (0.15 m), the behavior was completely different for both compounds. NO was always greater than the above levels (from 5 to 41 m), showing two peaks (Fig. 7b): the first one around 15 ppb at 06:00 LT and the second one around 20 ppb at 17:00 LT. concentrations at soil level were relatively constant, ranging from 7 to 12 ppb; even in this case two peaks were observed: at 6:00 LT (10 ppb) and around 17:00 LT (11 ppb).
NO and fluxes at ground level were almost always monodirectional with NO emitted from soil and deposited to the ground (Fig. 7c). A strong increase in the emission rate of NO and the deposition of was observed after the precipitation events occurred between 6 and 7 July (Fig. 7d).
Fluxes and concentrations of NO and . (a) Average diel course of concentrations at the five levels (41, 32, 24, 16 and 5 m); (b) average diel course of NO concentrations; (c) soil NO and fluxes and NO fluxes at 32 m before rainfall events; (d) soil NO and fluxes and NO fluxes at 32 m after rainfall events (green line); (e) average diel course of soil NO and fluxes and of NO fluxes at 32 m. Please note the different scale between (c) and (d). Vertical bars in (a), (b) and (e) represent the standard error of the mean.
[Figure omitted. See PDF]
The average diel course of soil fluxes showed an almost constant emission of NO and two decreases: the first one around 06:00 LT and the second one at 17:00 LT. These two decreases in the observed fluxes were strictly linked to the stratification of the air above ground: an increase in the concentrations in a stratified environment led to a reduction in the concentration gradient between soil–litter and the atmosphere, thus reducing the emission fluxes. The average diel course of deposition was nearly inversely proportional to the behavior of the NO soil fluxes, with a pronounced reduction of the deposition early in the morning and a less intense one in the afternoon. In the afternoon, the nearly simultaneous minimum of soil NO fluxes and maximum of deposition (Fig. 7e) indicates a gas-phase titration with an reduction due to NO (Fig. 5).
At the top of the canopy the net exchange of NO with the above atmosphere was very small, except in the morning, when the deposition peak between 06:00 and 11:00 LT reached g N m s (Fig. 7e). This NO deposition (Fig. 7e) is correlated to the development of a small NO gradient above the canopy (Fig. 7b) after the photolysis. The NO gradient and fluxes became negligible (Fig. 7b and e) when the concentrations reached a minimum (Fig. 7a) determined by the photolytic equilibrium of .
Discussion
While turbulence and heat fluxes inside tree canopies have been extensively investigated, only a few studies have attempted to partition fluxes using flux measurements at different in-canopy heights (Dorsey et al., 2004; Launiainen et al., 2013).
The evaluation of flux profiles relies on the constant flux hypothesis, one of the fundamental theories of micrometeorology (Arya, 2001). In the case of the Bosco Fontana measurements, it was expected that the fluxes measured at 41 and 32 m were almost equal because both heights are above the forest canopy level, and that the deposition flux should decrease, in absolute terms, at the lower levels due to the presence of different in-canopy sinks for (stomata and surfaces of the leaves, branches and stems). However, although fluxes were similar at the two above-canopy heights (41 and 32 m) and within the uncertainty of the measurement, during the morning hours deposition at 24 m was significantly higher than at the two upper levels (32 and 41 m). Actually, between 09:00 and 12:00 LT, fluxes at 24 m were on average nearly 3 nmol m s higher than above the canopy (Fig. 6), while they were nearly equal between 13:00 and 18:00 LT (fluxes at 24 m were only 0.5 nmol m s higher).
A possible explanation of the higher fluxes at 24 m could lie in the different footprints of the eddy covariance measurements coupled with the heterogeneity of the canopy (Dalponte et al., 2007; Acton et al., 2016). The footprints of the measurements at 41, 32 and 24 m all fell inside the surface of the upper forest canopy, even though the 24 m level was just at the top canopy edge. The size of the footprint areas decreased at decreasing measuring heights. However, without any source or sink of the considered scalar, the horizontal homogeneity of the ecosystem studied ensures the validity of the constant flux hypothesis and thus the measurements referred to different footprints should be the same; i.e., fluxes with larger footprints (measurements at 41 and 32 m) should be comparable to those with smaller footprints (measurements at 24 m).
Regarding the possible role of BVOC emissions on the deposition fluxes, a partition exercise showed that less than 3 % of the deposited to the Bosco Fontana forest was destroyed by reactions with isoprene (Eiko Nemitz, personal communication, 2013), which was the most emitted BVOC at the site (Schallahart et al., 2016). The reaction of with isoprene was estimated from the methylvinylketone (MVK)/methacrolein (MACR) flux measured above the canopy by Schallahart et al. (2016) by means of a PTR-ToF spectrometer (71 atomic mass units), and by neglecting the fact that MVK/MACR can also be directly exchanged with the vegetation and produced by the competing isoprene vs. OH reaction. This result suggests a minor influence of the BVOC emissions on the enhancement of the fluxes observed at the top of the canopy (24 m) in the morning. However, we cannot exclude that fast reactions between and undetected highly reactive BVOCs occurred, e.g., with isoprenoids emitted at the canopy level such as the -caryophyllene, a sesquiterpene which reacts in the gas phase in few seconds to produce both unidentified oxidized VOCs and SOA, as highlighted by Goldstein et al. (2004).
To investigate alternative reasons for the enhancement of the fluxes at 24 m a spectral analysis was performed to compare the normalized cospectra of the fluxes at the different levels, and the role of the NO-related chemical sink was analyzed. Figure S5 shows the average normalized cospectra of the vertical component of wind and for the measurements performed when the morning enhancement at 24 m occurred (11:00 LT) and when the 24 m fluxes were comparable with the upper ones (15:00 LT). The cospectra analysis did not provide an obvious explanation for the enhancement of the fluxes observed at 24 m in the morning. Apart from the cospectra at 16 m, which had a very irregular behavior, the other three cospectra did not show any particular difference, which could explain the higher fluxes at 24 m. The observed decrease in the cospectra at 24 and 16 m for frequencies above 0.1 Hz is consistent with the notion that within the canopy the mean eddy size is dictated by the canopy height.
The analysis of the NO-related chemical sink revealed a possible role of the convergence of two NO fluxes at the top of the canopy (i.e., the NO deposition flux from the air above the forest and the soil NO emission flux uprising from the forest floor) on the enhancement of the fluxes at 24 m. This can be argued by considering the differences between the fluxes measured at 24 m and those measured at 32 m (a level where the constant flux hypothesis is confirmed). The sum of these differences from 06:00 to 12:00 LT gives a value of 59.4 mol m, which is almost equal to the sum of the NO converging to the top of the canopy, both from above and below in the same hours (54 mol NO m).
Assuming a stoichiometric reaction between NO and at the top of the canopy, the part of the flux not due to this chemical sink is obtained by subtracting to the 24 m fluxes value an amount of equal to the NO converging at the top of the canopy during each half hour. This is shown in Fig. 8, where the measured flux at 24 m is represented as a green line and the resulting part of the flux at 24 m not due to the NO-related sink is reported as a dark grey dashed line, while the NO fluxes converging from above and below canopy are represented by the black and purple lines, respectively.
The good agreement during the daylight hours between the fluxes at 32 m (Fig. 8, red line) and the part of the flux at 24 m not due to the NO-related sink (Fig. 8, dark grey dashed line) suggests that the enhancement of the fluxes observed at 24 m was related to the interactions between and NO at the top canopy level. However, at night there might be an overcorrection of the flux at 24 m (Fig. 8) because, in case of high atmospheric stability, the NO emitted from soil could stratify near the forest floor and react below the canopy.
Average diel course of fluxes at 32 m (red line), fluxes at 24 m (green line), NO fluxes at 32 m (black line), NO fluxes at soil level (purple line) and the modified (MOD) fluxes at 24 m (dashed grey line). This latter takes into account the role of the NO-related sink.
[Figure omitted. See PDF]
The coupling between the forest and the atmosphere above the canopy was found to have an important role on the regulation of the flux enhancement at 24 m, facilitating this mechanism particularly during the morning hours when the in-canopy mixing processes were well developed. In fact, the decrease in the NO concentrations at soil level (Fig. 7b) from 06:00 to 12:00 LT suggests a relatively well-mixed forest canopy, which is better coupled with the atmosphere above. This condition also allowed and NO from the above-canopy air to penetrate more easily into the canopy (see Fig. S2b and the morning peak of Fig. 7b). On the contrary, the increase in the NO concentrations at soil level (0.15 m, Fig. 7b) after midday, followed by the decrease in concentrations at the same level (Fig. 5), suggests that an air stratification occurred inside the canopy in the afternoon with a decoupling from the above-canopy air, as also found by Rummel et al. (2002) and Foken (2008). The afternoon stratification was also supported by the stability classes reported in Fig. 4c and d, which denoted almost always stable or very stable atmospheric conditions both at 16 and 24 m from 15:00 to 18:00 LT. In addition, the thermal inversion layer within the canopy increased its thickness during the afternoon (Fig. 2b) rising from 16 m (around 12:00 LT) to 24 m (between 14:00 and 16:00 LT). Again, the morning coupling and the afternoon decoupling was supported by the diurnal course of the specific humidity observed below the canopy (Fig. 1a). In the morning the almost constant amount of water vapor above and below canopy (other than the 24 m level, where there was an unidentified process removing water vapor) reveals an efficient mixing of the air, while in the afternoon, the increase in the specific humidity from the three lower levels, due to soil evaporation and understorey transpiration, reveals an air stratification below the canopy and a forest decoupling from the above atmosphere.
Average diel course of the removal by the different forest layers and by the NO emitted from the forest floor.
[Figure omitted. See PDF]
The availability of flux measurements at different heights within and above the canopy allowed a partition of the fluxes among the different ecosystem layers: upper and lower canopy, understorey, and soil. To do that we assumed the flux measured at 32 m to be the total deposition flux, and then calculated the overall NO sink as the sum of the NO deposited from the above atmosphere and the NO emitted from the soil, considering a stoichiometric reaction between NO and . The uptake due to the upper canopy layer was identified as the difference between the fluxes measured at 32 m and those measured at 16 m (ignoring the apparently enhanced values at 24 m), while the uptake due to the lower canopy layer was obtained as the difference between the fluxes measured at 16 and 5 m. Finally, the deposition to the forest floor (soil and the understorey vegetation) was calculated as the difference between the flux at 5 m and the NO flux emitted from the soil, namely the amount of , which is not removed by chemical reaction with NO.
The result of this test is shown in Fig. 9, where it can be observed that on a daily basis the upper canopy layer of the forest removed about one-third of the total deposited (between 07:00 and 22:00 LT) while the lower canopy layer of the forest removed the main part of the (46.5 %, between 08:00 and 22:00 LT).
The canopy removed nearly 80 % of the deposited to the forest ecosystem, but it is worth noting that this amount included stomatal uptake and nonstomatal processes such as dry deposition on physical surfaces (e.g., leaves and bark) and chemical reactions in ambient air. Only a minor part of was removed by the understorey vegetation or deposited to the soil (2.0 %), while an important role was played by the NO-related sink, mainly due to soil emissions, which accounted for 18.2 % of the total deposition.
This latter result is in agreement with the observations of Dorsey et al. (2004) who found that in a Douglas fir plantation, between 7 % and 14 % of the deposition in the daylight hours could be attributed to reactions with the NO emitted from soil, while this fraction increased up to 41 % during the night. Similarly, Pilegaard (2001) found that the NO sink accounted for 25 % of the deposition in a Norway spruce forest, with an increase in this fraction up to 31 % during the night.
Nearly all of the nighttime deposition at Bosco Fontana can be attributed to depletion due to NO. The fact that NO reaction accounts for 100 % of the nocturnal deposition would imply that other nonstomatal sinks are negligible during that time. However, it cannot be excluded that some nonstomatal deposition of took place since our stirred soil flux chambers could somewhat overestimate the nocturnal soil NO emission, due to the enhanced amount of mixing in the flux chamber compared with the true forest floor during calm nights. Similarly, the analysis assumes that the only sink for NO is its reaction with . A small NO uptake by vegetation is possible even if unlikely, as shown by Teklemariam and Sparks (2006) and Stella et al. (2013). Overall this ecosystem did not behave as a net NO emitter because all NO produced at soil level is consumed within the canopy, but as a weak NO sink because of the small amount of NO received from the atmosphere in the first hours of the morning (Fig. 7d). This differs from the observation of Dorsey et al. (2004), who estimated that nearly 60 % of the NO emitted from the soil of a Douglas fir forest escaped the trunk space to react aloft.
Conclusions
Ozone flux measurements were carried out at five levels (above, inside and below the canopy) along a vertical profile of a mature broadleaf forest during the ECLAIRE joint field campaign. The data collected are particularly relevant since no measurements of fluxes were previously available in the literature for an oak–hornbeam mature forest. Ozone fluxes measured at the two levels above the canopy were in good agreement and comparable to those reported for other forest types (Amthor et al., 1994; Gerosa et al., 2005; Hogg et al., 2007; Rummel et al., 2007; Finco et al., 2017). Ozone fluxes at 16 and 5 m were lower than above the canopy, while at the top canopy edge (24 m) fluxes were surprisingly higher than above in the morning hours. The main cause of this enhancement was attributed to a chemical sink due to a reaction between and NO, which was emitted from the soil and deposited from the atmosphere above the canopy.
The morning enhancement of the fluxes at 24 m was favored by the coupling between the forest and the atmosphere, while in the afternoon the decoupling and the in-canopy stratification led to 24 m fluxes comparable to those above the canopy.
Most of the , nearly 80 %, was removed by the forest canopy through stomatal uptake, dry deposition on physical surfaces and ambient chemistry: in particular, the upper canopy layer removed 33.3 % of the deposited and the lower canopy layer 46.3 %. Only a minor part of was deposited on the soil and the understorey (2 %), while the remaining part (18.2 %) was removed by a chemical reaction with NO emitted from soil. These findings might be useful for improving the risk assessment for mature forests.
The collected data will be available for the parameterization and the fine-tuning of process models aimed at correctly reproducing the in-canopy dynamics of the reactions between and , as these dynamics might significantly influence the biosphere–atmosphere exchange budgets of and other reactive trace compounds with further implications for air quality and productivity of the forest ecosystems.
Data are freely available on request at the DATABASE REPOSITORY of the ECLAIRE fp7 Project (Owen, 2012).
The supplement related to this article is available online at:
EN designed and coordinated the ECLAIRE measuring campaign at Bosco Fontana. MC, EN, AF, GG, SF and BL performed the EC and meteorological measurements at the five levels. MC performed the gas concentration measurements along the vertical profile above and within the canopy. ED-P and RG performed the soil flux measurements and their analysis. AF and GG performed the EC data processing and the full data analysis with contributions by the other coauthors. GG, AF, RM and MC wrote the paper with the contribution from all coauthors.
The authors declare that they have no conflict of interest.
Acknowledgements
The authors are grateful to the administration and the personnel of the Bosco Fontana National Reserve for their availability and continuous support, and to the European Union for having funded the project ECLAIRE under which this campaign was performed.
This publication was funded by the Catholic University of the Sacred Heart in the framework of its programs of promotion and dissemination of the scientific research. Edited by: Alex B. Guenther Reviewed by: two anonymous referees
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
© 2018. This work is published under https://creativecommons.org/licenses/by/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.
Abstract
A 1-month field campaign of ozone (
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Details







1 Dipartimento di Matematica e Fisica, Università Cattolica del S. C., Brescia, Italy
2 Centre for Ecology & Hydrology, Bush Estate, Penicuik, UK
3 Institut National de la Recherche Agronomique, Thiverval-Grignon, France
4 Council for Agricultural Research and Economics, Research Centre for Forestry and Wood, Arezzo, Italy
5 Institute of Soil Research, University of Natural Resources and Life Sciences (BOKU), Vienna, Austria
6 Institute of Meteorology and Climate Research Atmospheric Environmental Research (IMK-IFU), Garmisch-Partenkirchen, Germany