Background
Studies have shown that patients who undergo trans-catheter aortic valve replacement (TAVR) have high rates of hospital readmission. Our objectives were to identify the causes of readmission after TAVR, determine whether transitional care factors were associated with a reduction in readmission and to identify other predictors that could be used to target quality improvement efforts.
Methods
We conducted a chart abstraction study that included all patients who underwent TAVR in Ontario, Canada between 2007 and 2013 and survived to hospital discharge. These data were linked to provincial administrative databases. The association between transitional care factors (home care, rehabilitation, family physician and cardiologist follow-up) and 1-year hospital readmission was examined using a time-to-event analysis. Cause-specific hazards models were used to account for the competing risk of death.
Results
There were 937 patients in the cohort and the rate of readmission at 1-year was 49%. The most common causes of readmission were heart failure and bleeding. Rehabilitation (HR 1.34, 95% CI 1.11–1.62; p = 0.002) and cardiologist follow-up (HR 1.41, 95% CI 1.14–1.75; p = 0.002) were both associated with higher readmission rates. While, home care (HR 1.18, 95% CI 0.96–1.44; p = 0.12) and family physician follow-up (HR 1.04, 95% CI 0.85–1.28; p = 0.71) were not associated with readmission.
Conclusion
Readmission post TAVR is common; however, we did not identify any transitional care factors associated with reductions in hospital readmission. This suggests ongoing research is required to identify targets for improvement in post-procedural care.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer