Full Text

Turn on search term navigation

© 2019 Chen et al. This is an open access article distributed under the terms of the Creative Commons Attribution License: http://creativecommons.org/licenses/by/4.0/ (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Objective

To design and evaluate the accuracy of a novel navigation template suitable for posterior cervical screw placement surgery by using 3D printing technology to improve the existing guiding template design.

Methods

The researchers (including spine surgeons and technicians) used CT to perform thin-slice scanning on 12 cases of normal upper cervical vertebral specimens and defined the screw channels that were completely located in the pedicle without penetrating the cortex as ideal screw channels, then designed the ideal channel of the upper cervical vertebral (atlantoaxial) pedicle screw by computer software which was regarded as the preset values, and recorded the screw entrance point, transverse angle and sagittal angle of the ideal channel. Then, researchers designed the novel navigation templates for placement pedicle screw according to the ideal screw channel preset values and manufactured them with one for every single vertebra by 3D printer. A senior spine surgeon performed the posterior surgery to implant pedicle screw on the specimens by the novel navigation templates, then performed CT thin-slice scanning on the specimens again after removing the screws, and reconstructed the actual screws channel by computer software, recorded the screw entrance point, transverse angle and sagittal angle of the actual channels which were defined as the actual values and evaluated them according to Kawaguchi’s pedicle screw evaluation standard finally. The differences between the preoperative preset values of ideal screw channel and the postoperative actual values of actual screw channel were compared by a nonparametric paired rank test.

Results

48 screws were placed on 12 cases of upper cervical vertebral specimens in total. It showed that the grade 0, I, II, III channels in this study were 47, 1, 0, 0, respectively. The grade 0 channels accounted for 97.92% of the total number of channels. There was no significant difference with regard to the screw entrance point, the transverse angle, and the sagittal angle between the preoperative preset values of ideal screw channels and the postoperative actual values of actual screw channels.

Conclusion

To implant pedicle screw assisted with the novel individually navigation template designed by 3D printed in the posterior cervical surgery can improve accuracy of pedicle screw placement and safety of the surgery.

Details

Title
Design and basic research on accuracy of a novel individualized three-dimensional printed navigation template in atlantoaxial pedicle screw placement
Author
Xiao-Long, Chen; ⨯ Ya-Fen Xie; Li, Jian-Xin; Wu, Wu; Guan-Nan, Li; Hui-Jing, Hu; Xiao-Yun, Wang; Zhao-Jian, Meng; Yue-Feng, Wen; Wen-Hua, Huang
First page
e0214460
Section
Research Article
Publication year
2019
Publication date
Apr 2019
Publisher
Public Library of Science
e-ISSN
19326203
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2202615966
Copyright
© 2019 Chen et al. This is an open access article distributed under the terms of the Creative Commons Attribution License: http://creativecommons.org/licenses/by/4.0/ (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.