Abstract

Purpose: To evaluate the optical quality and tear-film dynamics in patients with aqueous-deficient or evaporative subtype of dry eye disease (DED). Methods: Twenty-five aqueous-deficient dry eye (ADDE) patients, 25 DED patients with meibomian gland dysfunction (MGD), and 25 healthy subjects were included in this study. Vision-related health-targeted quality of life was evaluated using the Ocular Surface Disease Index (OSDI) questionnaire. Dynamic recording with a double-pass system (Optical Quality Analysis System [OQAS]) was performed in right eyes. Scattered light was measured as the objective scatter index (OSI) at 0.5-second intervals over 20 seconds without blinking. Then, we recorded OSI every 0.5 seconds within a 20-second period with the subjects asked to blink freely. Several parameters were established to evaluate the dynamic alterations of optical quality and the effects of blinks: OSI, OSI standard deviation (SD), ΔOSI, ΔOSI/time, blinking change (BC), and blinking frequency (BF). Additional clinical examination included tear film break-up time (BUT), Schirmer I test (SIT), fluorescein staining grade (FL), meibomian gland quality, meibomian gland expressibility, and meibomian gland drop-out. Results: The OSI, SD, ΔOSI, ΔOSI/time, BC, and BF were significantly higher in DED patients than controls (P < 0.01, respectively). The OSI, SD, ΔOSI, ΔOSI/time, BC, and BF were significantly higher in patients with MGD than patients with ADDE (P < 0.01). In the MGD group, BUT, FL staining score, lid abnormality, meibomian gland expressibility, and meibomian gland drop-out were correlated with Δ OSI and Δ OSI/time. Conclusion: Dry eye patients with MGD had significant alterations of optical quality compared with ADDE patients. The double-pass system has potential to be a useful quantitative method to evaluate the optical quality and tear-film dynamics in patients with dry eye.

Details

Title
Objective optical assessment of tear-film quality dynamics in patients with meibomian gland dysfunction and aqueous-deficient dry eye optical quality changes in different dry eye subtypes
Author
Ye, Fen 1 ; Jiang, Feng 2 ; Lu, Yan 1 ; Xue, Chun 1 ; Zhu, Xiao 1 ; Wu, Yan 1 ; Huang, Zhen 1 

 Department of Ophthalmology, Jinling Hospital of Nanjing Medical University, Nanjing 210002, Jiangsu Province 
 Department of Ophthalmology, The Affiliated Sir Run Run Hospital of Nanjing Medical University, Nanjing 210002, Jiangsu Province 
Pages
599-603
Publication year
2019
Publication date
May 2019
Publisher
Medknow Publications & Media Pvt. Ltd.
ISSN
03014738
e-ISSN
19983689
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2213810765
Copyright
© 2019. This work is published under https://creativecommons.org/licenses/by-nc-sa/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.