Abstract
Background
Surgical reconstruction of the Medial Patello-Femoral Ligament (MPFL) has been recognized as an effective treatment for patients with instability despite conservative treatment. The purpose of this cadaveric study is to compare the strain patterns within the native and reconstructed single and double-bundle MPFL. This will help ascertain if the native biomechanics are restored with the reconstructions.
Methods
Twelve cadaveric knees were dissected and the native MPFL of each specimen was identified. The knees were subjected to dynamic flexion using a customized jig. Continuous strain measurements were taken for each knee from 0 to 120 degrees flexion and then back to full extension using differential variable reluctance transducers (DVRTs). The MPFL was then cut. Six single bundle and six double bundle MPFL reconstructions were performed using hamstring tendon grafts. The DVRTs were reattached to the grafts and strain measurements were retaken. Statistical analysis was performed using a paired t-test.
Results
Strain patterns of the native and reconstructed MPFL showed an increase in strain from 0 to 120 degrees of flexion except for the inferior bundle of the double bundle reconstruction. The strain patterns in the intact specimens were higher than the reconstructed MPFL through different degrees of knee flexion. In the double-bundle group, the superior graft had statistically significantly lower strains compared to the native MPFL with p-value <.05 at all flexion angles. The reconstructed inferior band showed loss of tension as the knee flexed. Higher strain with statistical significance (p-value <.05) was found in the single-bundle compared to the superior band of the double-bundle reconstruction at flexion angles less than 90 degrees.
Conclusion
The strain variation at progressive angles of knee flexion is dissimilar between the native and reconstructed MPFL. The reconstructed MPFL exhibited non-physiological biomechanics with the inferior band losing tension. Although the single-bundle reconstruction shows a better strain profile compared to double-bundle reconstruction, the grafts are significantly stiffer than the native MPFL.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Details
1 Department of Orthopaedic Surgery, Singapore General Hospital, Singapore, Singapore