© 2019 Nemcansky et al. This is an open access article distributed under the terms of the Creative Commons Attribution License: http://creativecommons.org/licenses/by/4.0/ (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Purpose

To evaluate the clinical efficiency, safety and painfulness of retinal laser photocoagulation employing a pattern scanning laser system Pascal given in a single-session versus conventional laser multiple-session treatment of the same patient with diabetic retinopathy during 12-month follow-up.

Methods

The cohort included 60 eyes in 30 patients treated at the Ophthalmology Clinic, Faculty Hospital Ostrava, from 2008 to 2013. Panretinal laser coagulation was performed on one eye using the multispot panretinal photocoagulation given in a single-session system Pascal (OptiMedica, Santa Clara, California). On the other eye laser treatment was carried out by the classic conventional multiple-session method.

Results

The performance of Pascal panretinal laser coagulation was evaluated as significantly less painful (visual scale of pain was 3.28 ± 1.9) than the performance of conventional photocoagulation (visual scale of pain was 3.93 ± 1.88) with similar efficiency. Distribution of progression of diabetic retinopathy in individual patients was very similar in both groups under comparison, and was strictly paired in 24 of the 30 patients at the end of 1-year follow-up.

Conclusion

Laser photocoagulation of the retina with the use of short impulse durations and patterns in patients with diabetic retinopathy given in one session possesses similar efficiency to that of conventional retinal photocoagulation in multiple sessions. The single session treatment is also better tolerated by patients and in addition to this, it shortens the performance of the whole therapy, which potentially saves considerable funds of all subjects participating in the process of treatment.

Trial registration

ClinicalTrials.gov NCT03672656.

Details

Title
Single session of pattern scanning laser versus multiple sessions of conventional laser for panretinal photocoagulation in diabetic retinopathy: Efficacy, safety and painfulness
Author
Nemcansky, Jan; Stepanov, Alexandr; Nemcanska, Sabina; Masek, Petr; Langrova, Hana; Studnicka, Jan
First page
e0219282
Section
Research Article
Publication year
2019
Publication date
Jul 2019
Publisher
Public Library of Science
e-ISSN
19326203
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2258714945
Copyright
© 2019 Nemcansky et al. This is an open access article distributed under the terms of the Creative Commons Attribution License: http://creativecommons.org/licenses/by/4.0/ (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.