Full text

Turn on search term navigation

© 2018. This work is published under http://creativecommons.org/licenses/by-nc/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Aims

Using the novel FreeStyle Libre (FSL), glucose monitoring (FGM) system becomes increasingly popular among people with type 1 diabetes (T1D) and is associated with less and shorter hypoglycaemic events without deterioration of HbA1c. There are not yet data reporting the impact of FGM in people with T1D in real‐life conditions. We sought of evaluating the tolerance, the acceptance and the efficacy of the FGM system in routine medical practice.

Methods

This 12‐month observational study included 120 individuals with T1D evaluated every 3 months. After having been instructed about FGM utilization, participants were trained to optimize the glycaemic control.

Results

Participants stopped immediately of measuring capillary blood glucose (2.88 ± 0.12 per day) (mean ± SEM) after having received the first FSL device and the number of scans per day increased up to 8.87 ± 0.58 per day. HbA1c levels decreased from 8.51% ± 0.14% at baseline to 7.77% ± 0.09% after 3 months to slightly increase to 7.92% ± 0.09% at 12 months, in correlation with the number of scans per day. The number (but not the duration) of hypoglycaemic events slightly increased from 16.9 ± 1.44 per month at baseline to 24.0 ± 2.91 per month at 12 months, after reaching a peak of 26.4 ± 2.31 per month at 6 months. They were correlated with improved HbA1c.

Conclusion

Our study shows that using the FGM system improves HbA1c levels in people with T1D along with a moderate increase in the number of mild hypoglycaemic events. The new FGM system facilitates the therapeutic empowerment of people with T1D, but in a context of structured education.

Details

Title
The new FreeStyle libre flash glucose monitoring system improves the glycaemic control in a cohort of people with type 1 diabetes followed in real‐life conditions over a period of one year
Author
Paris, Isabelle 1 ; Henry, Corinne 1 ; Pirard, Françoise 1 ; Anne‐Catherine Gérard 1   VIAFID ORCID Logo  ; Colin, Ides M 1 

 Service d'Endocrino‐Diabétologie (CRPO), Unité de Recherche Clinique en Endocrinologie (URCE), Centre Hospitalier Régional (CHR) Mons‐Hainaut, Mons, Belgium 
Section
ORIGINAL ARTICLES
Publication year
2018
Publication date
Jul 2018
Publisher
John Wiley & Sons, Inc.
e-ISSN
23989238
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2266871656
Copyright
© 2018. This work is published under http://creativecommons.org/licenses/by-nc/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.