Full text

Turn on search term navigation

© 2019 Buytaert et al. This is an open access article distributed under the terms of the Creative Commons Attribution License: http://creativecommons.org/licenses/by/4.0/ (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Introduction

Cardiac catheterization procedures result in high radiation doses and often multiple procedures are necessary for congenital heart disease patients. However, diagnostic reference levels (DRL) remain scarce. Our first goal was finding the optimal DRL parameter and determining appropriate DRLs. The second goal was to calculate organ doses (OD), effective doses (ED) and lifetime attributable risks (LAR) per procedure and to provide conversion factors based on dose area product (DAP).

Materials and methods

DRLs are calculated for each procedure type, as the 75th percentile of the cumulative value per procedure from the corresponding parameter. All irradiation events in the DICOM Structured Reports were automatically processed and simulated using PCXMC, resulting in OD, ED and LAR. Using a Kruskal Wallis H test and subsequent pairwise comparisons, differences in median values of the DRL parameter between procedure types were assessed.

Results

Linear regression showed a strong correlation and narrow confidence interval between DAP and product of body weight and fluoroscopy time (BWxFT), even when all procedures (diagnostic and interventional) are combined. Only 15% of the pairwise comparisons were statistically significant for DAP normalized to BWxFT (DAPBWxFT). The latter pairs contained less frequent procedure types with significant outliers. For DAP normalized to BW (DAPBW), 38% of the pairwise comparisons showed statistically significant differences. Conversion factors from DAPBW to OD and ED were reported for various weight groups, due to the higher correlation between DAPBW and both OD and ED than between DAP and both OD and ED.

Conclusions

The P75 of DAPBWxFT for all procedures combined serves as an appropriate DRL value. This facilitates local DRL determination in smaller paediatric centres, which often have insufficient data to produce appropriate DRLs for different procedure types. Conversion factors are more reliable starting from DAPBW instead of DAP and should be used according to the appropriate BW group.

Details

Title
Local DRLs and automated risk estimation in paediatric interventional cardiology
Author
Buytaert, Dimitri; Vandekerckhove, Kristof; Panzer, Joseph; Rubbens, Lukas; De Wolf, Daniël; Bacher, Klaus
First page
e0220359
Section
Research Article
Publication year
2019
Publication date
Jul 2019
Publisher
Public Library of Science
e-ISSN
19326203
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2267556440
Copyright
© 2019 Buytaert et al. This is an open access article distributed under the terms of the Creative Commons Attribution License: http://creativecommons.org/licenses/by/4.0/ (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.