Full Text

Turn on search term navigation

© 2019 Cho et al. This is an open access article distributed under the terms of the Creative Commons Attribution License: http://creativecommons.org/licenses/by/4.0/ (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Background

Pancreatic pseudocysts (PC) and walled-off necrosis (WON) are common complications of severe pancreatitis. Endoscopic ultrasound (EUS)-guided drainage has replaced surgery as the standard treatment for PC/WON. We developed a novel lumen-apposing metal stent (LAMS) with an anti-reflux valve to prevent infectious complications caused by food reflux into the cyst cavity. This retrospective study investigated the efficacy and safety of EUS-guided drainage using this LAMS.

Methods

We investigated and compared the treatment outcomes and complications rates between EUS-guided drainage using a novel LAMS (n = 10) versus plastic stents (n = 18) from December 2013 to October 2016. Technical success was defined as successful stent placement without immediate complications. Clinical success was defined as resolution of the PC/WON and disappearance of symptoms.

Results

Among 10 patients in LAMS group, 4 patients had complicated PC and 6 patients had WON. In the plastic stent group, 15 and 3 patients had PC and WON, respectively. The median fluid collection size before treatment was 82.5 (interquartile range [IQR], 60.75–118.25) mm and 92.0 (IQR, 75.75–130.25) mm in the LAMS and plastic stent groups, respectively. There were no statistically significant differences in technical success rates (90% vs. 94.4%; p = 0.999), clinical success rates (80% vs. 77.8%; p = 0.999), and complication rates (20% vs. 27.8%; p = 0.999) between the two groups.

Conclusions

Treatment outcomes of EUS-guided drainage using a novel LAMS were feasible despite the significantly high proportion of WON. The LAMS allowed acceptable treatment outcomes for EUS-guided drainage.

Details

Title
A novel lumen-apposing metal stent with an anti-reflux valve for endoscopic ultrasound-guided drainage of pseudocysts and walled-off necrosis: A pilot study
Author
In Rae Cho; Moon Jae Chung; Jung, Hyun Jo; Lee, Hee Seung; Park, Jeong Youp; Bang, Seungmin; Seung Woo Park; Si Young Song
First page
e0221812
Section
Research Article
Publication year
2019
Publication date
Sep 2019
Publisher
Public Library of Science
e-ISSN
19326203
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2284757570
Copyright
© 2019 Cho et al. This is an open access article distributed under the terms of the Creative Commons Attribution License: http://creativecommons.org/licenses/by/4.0/ (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.