This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
1. Introduction
Chinese medicine has been developed for over two thousand years. Pulse diagnosis in Chinese medicine provides a noninvasive method based on the radial pulse feeling of the fingers with temporal and spatial characteristics. In order to measure and analyze these pulses, several pulse diagnostic instruments (PDIs) were developed based on array sensors for detecting not only the temporal characteristics but the spatial characteristics of the pulse [1–3]. Luo and colleagues [4–6] used the PDI with tactile array sensors to get the radial artery pressure signal transformed into a visualized three-dimensional waveform, called a three-dimensional pulse image (3DPI). Three types of pulse feeling have been well transformed into 3DPI: normal pulse, taut pulse, and slippery pulse [7].
The signal analysis of 3DPI has been gradually paid attention in recent years. Cui et al. [8] proposed a method for distinguishing taut pulse from normal and slippery pulse based on array pulse volume (APV), defined as the average volume of signals in a pulse cycle. Su et al. [9] suggested to conveniently distinguish normal and taut pulses by contour analysis of the spatial structure, and Luo et al. [10] proposed the L-cube polynomial to describe the 3DPI patterns of these two types.
There are a lot of analytic methods in single pulse wave analysis (PWA) [11–24], of which fast Fourier transform (FFT), Hilbert–Huang transform (HHT), wavelet transform (WT), etc. are efficient ways of viewing waveforms in frequency or time domain. However, it is shown that Fourier series can well present the component of pulse waves given the periodicity of the cardiovascular system [25–30]. Since the pulse signal in a short period of time can be treated as a periodic signal due to its small nonlinearity [27, 31], Fourier series is considered a unique and powerful pulse analysis method. Given that the spatial properties of the pulse need to be further analyzed, this study intends to determine the features of three pulse types using Fourier series expanding from one-dimensional to three-dimensional pulse analysis.
2. Materials and Methods
2.1. Experimental Data
The pulse data in this research were collected from healthy subjects using the PDI (IRB no: A-BR-100-166). The subjects included 14 males and 10 females from college students (Table 1). The target three types of pulse were first verified by Chinese medicine practitioners’ palpation based on the Chinese medicine theory [32], and finally confirmed by the peripheral augmentation index (pAI), which was defined as the ratio of percussion and tidal wave as well as regularly used in Chinese medicine pulse pattern research [9, 21, 33–35]. Normal pulse data were obtained from these subjects in normal state, taut pulse images were induced by cold pressor test (CPT) [9, 36, 37], while slippery pulse images were measured from woman subjects during the menstrual cycle [7]. The pulse wave signals at the left wrist on a participant were recorded by the tactile array sensor on position “Guan” of the PDI [1]. The PDI thus continuously recorded 12-channel pulse wave signals during the CPT for each participant. There are three robot fingertips in the PDI with 12-point (3 × 4) sensors on their tips, and each 12-point tactile sensor array has the size of 1 cm × 0.75 cm with 100 Hz sampling rate [1, 5, 7, 38].
Table 1
Basic physiological data of the subjects.
Characteristic (unit) | Number or mean ± SD |
---|---|
Number | 24 (male = 14, female = 10) |
Age (years) | 22.2 ± 3.7 |
BMI (kg/m2) | 20.4 ± 1.4 |
Systolic/diastolic blood pressure (mmHg) | 112.1/74.0 ± 4.7/3.4 |
Heart rate (beats/min) | 76.0 ± 5.4 |
2.2. Experimental Procedure
A flowchart (Figure 1) is given to show the way to conduct pulse image analysis. First, we took the readings from the sensor arrays in the form of a column matrix with a sampling frequency of 100 Hz. The 0.1–20 Hz bandpass Butterworth filter was used to reduce the noise, and baseline drift was greatly decreased by wavelet transform [38, 39]. 3DPI is formed by using a cubic interpolation algorithm to expand graphic data points [40], and a two-dimensional pulse image (2DPI) is formed from 3DPI by taking the middle pulse data along the center of the radial artery. Fourier series was adopted to analyze the radial pulse images.
[figure omitted; refer to PDF]
Figure 2 shows a multidimensional pulse image: 3DPI (upper panel) at the peak pulse and d2DPI (dynamic 2DPI, lower panel) of one beat for (a) normal, (b) taut, and (c) slippery pulses. The d2DPI clearly demonstrates the temporal response with one spatial information of array pulse signals, while 3DPI just presents two spatial data without temporal responses in the figure.
[figures omitted; refer to PDF]
In Figure 3(a), d2PDI of a slippery wave is further clearly demonstrated by temporal and spatial responses separately, in which the temporal pulse in one beat is same as the regular single pulse wave, and the wave shape of the spatial pulse is presented along the center of the radial artery. Two spatial peaks move up and down alternately in a slippery 3DPI shown in Figure 3 marked with a triangle and a rectangle.
[figures omitted; refer to PDF]
The first peak moves to its maximum (
2.3. Primary Algorithm
A general Fourier series analysis is applied to calculate the temporal or spatial harmonic components of normal, taut, and slippery d2DPIs shown below:
C n is the amplitude of the temporal or spatial harmonics for x and X = time or length separately.
Fourier series with seven or eight harmonics is empirically adequate for 99.5% of the variance for one-dimensional temporal wave [41, 42], while the qualified harmonic number of spatial Fourier series is educed to three, on account of the simplicity of the spatial wave shape in this study.
3. Results and Discussion
3.1. Temporal Fourier Series
Figure 4 shows the amplitudes of the temporal Fourier series for normal, taut, and slippery pulse images separately. Even there is a little variation in these three temporal pulse waves, but their harmonic amplitudes make no remarkable changes.
[figures omitted; refer to PDF]
3.2. Spatial Fourier Series
Figures 5–6 presents the amplitudes of spatial Fourier series for normal and taut pulse images. By neglecting the base amplitude at 0 Hz (C0), the first (C1) and second (C2) harmonics show a remarkable difference in amplitudes between normal and taut pulse images. C1 is much bigger than C2 at normal pulse image, while C1 is almost equal to C2 at taut pulse image. At taut pulse image, most of the amplitude is accumulated at the base because the taut pulse image looks like a rectangular pulse with little harmonics in the spatial length along the radial artery.
[figures omitted; refer to PDF]
[figures omitted; refer to PDF]
Figures 7–8 show the spatial Fourier series at the first and second peak maximums (
[figures omitted; refer to PDF]
[figures omitted; refer to PDF]
3.3. Spatial Harmonic Ratio Sequence
To make the recognition among these three pulse images, harmonic ratios (r0, r1, and r2) are defined as follows:
For a cardiac cycle, we can get a spatial harmonic ratio sequence from d2DPI. Figure 9 demonstrates three spatial harmonic ratio sequences of consecutive three beats for normal, taut, and slippery pulses. To avoid noise interference at small amplitudes, ratio sequences are not calculated for the pulse with its peak less than 5% of peak maximum [27]. The harmonic ratio sequence of normal pulses in Figure 9(a) is well distributed without any intersection. For taut pulses in Figure 9(b), the base ratio sequence is always far beyond the first and second harmonic ratio sequences which are almost merged together. Regarding slippery pulses in Figure 9(c), its first and second harmonic ratio sequences intersect each other at the upstroke phase due to two peaks oscillating alternatively. Occasionally, the first harmonic ratio sequence becomes high enough to interact with the base harmonic ratio sequence. Apparently, the behavior of three harmonic ratio sequence showing remarkable differences creates the capability of the recognition among normal, taut, and slippery pulse images (Table 2).
[figures omitted; refer to PDF]
Table 2
Fourier series analysis of normal, taut, and slippery pulses.
Pulse type | Fourier series analysis of spatiotemporal pulse waves | ||
---|---|---|---|
Temporal analysis | Spatial analysis | Spatial harmonic ratio sequence | |
Normal pulse | Undistinguishable | Base and first harmonic share importance | Three sequences are well distributed |
Taut pulse | Behaves as a rectangular pulse with dominant base and little harmonics | Base is high, and others merged together | |
Slippery pulse | The first harmonic can be higher or lower than the second one | Three sequences intersect each other |
3.4. Statistics
In this study, the first harmonic ratio average
[figure omitted; refer to PDF]
Table 3
Spatiotemporal pulse statistics.
Methods and indexes | Normalized value | ||
---|---|---|---|
Normal pulse | Taut pulse | Slippery pulse | |
pAI |
0.65 ± 0.05 | 0.75 ± 0.07 | 0.50 ± 0.03 |
Array pulse volume [8] | 1.85 ± 0.22 | 2.30 ± 0.33 | 2.18 ± 0.13 |
2DL from contour analysis [9] | 0.45 ± 0.06 | 0.75 ± 0.11 | — |
r Lc from L-cube polynomial [10] | 1.21 ± 0.15 | 2.14 ± 0.44 | — |
[ |
[0.39 ± 0.04, 0.00 ± 0.02] | [0.25 ± 0.05, 0.03 ± 0.04] | [0.32 ± 0.03, 0.16 ± 0.03] |
All the indexes are calculated for pulse datasets with normalized amplitude from 0 to 1 and analyzed using one-way analysis of variance (ANOVA). A
Table 4
Indexes |
|
||
---|---|---|---|
Normal-taut | Taut-slippery | Slippery-normal | |
pAI | 0.0016 | 0.0000 | 0.0000 |
APV | 0.0014 | 0.2809 | 0.0006 |
2DL | 0.0000 | — | — |
r Lc | 0.0000 | — | — |
|
0.0000 | 0.0009 | 0.0002 |
|
0.0274 | 0.0000 | 0.0000 |
According to statistical analysis, APV is unable to entirely differentiate taut and slippery pulses (2.30 ± 0.33 vs. 2.18 ± 0.13;
Apparently, normal, taut, and slippery pulse images can be differentiated by
As an arterial stiffness index of a single temporal pulse wave [35], our results in Table 3 agree with the previous classification research that the pAI value of a normal pulse is higher than that of a slippery pulse while lower than that of a taut pulse [33]. It is worth noting that a taut pulse and a tight pulse in Chinese medicine are in similar shape and related to vessel tensing [32]. It is suggested that CPT on a healthy subject’s hand and wrist [9, 36, 37] can briefly increase arterial stiffness to induce a taut pulse, not a tight pulse, which fairly presents illness.
4. Conclusions
Fourier series is provided as a fast, robust, and real-time able method to analyze 3DPIs. It is difficult to differentiate these three types of pulses (normal, taut, and slippery) for the temporal Fourier series only because the definition of pulse feeling in Chinese medicine takes the spatial waveshape factor into account [1, 5, 7]. In comparison with temporal Fourier analysis in Table 2, the spatial Fourier analysis can distinguish among normal, taut, and slippery pulse images. For the Fourier series analysis of three spatiotemporal 3DPIs (normal, taut, and slippery), the proposed harmonic ratio sequence clearly shows apparently different behavior among three pulse images, and there are statistical differences between them by
In this study, taut pulses were induced by CPT, not collected from hypertensive patients. Normal and slippery pulse images were obtained from young people. In the near future, lots of 3DPI should be collected from patients with different ages and several kinds of hypertension to testify the statistical recognition rate of the proposed ratio sequence. Furthermore, various methods such as WT and HHT can be introduced to study the spatiotemporal characteristics of all types of 3DPI, not limited only with normal, taut, and slippery pulse images.
Acknowledgments
This research was supported by National Cheng Kung University, Taiwan, under NCKU Top University Program, and Sun Yat-sen University, China, under Scientific Initiation Project no. 67000-18821109 for high-level experts.
[1] C.-S. Hu, Y.-F. Chung, C.-C. Yeh, C.-H. Luo, "Temporal and spatial properties of arterial pulsation measurement using pressure sensor array," Evidence-Based Complementary and Alternative Medicine, vol. 2012,DOI: 10.1155/2012/745127, 2012.
[2] D. M. Wang, D. Zhang, G. M. Lu, "A novel multichannel wrist pulse system with different sensor arrays," IEEE Transactions on Instrumentation and Measurement, vol. 64 no. 7, pp. 2020-2034, DOI: 10.1109/tim.2014.2357599, 2015.
[3] K. W. Kong, W. M. Lau, K. S. Wong, "A pulse-sensing robotic hand for tactile arterial palpation," Proceedings of the 2016 IEEE International Conference on Cyber Technology in Automation, Control, and Intelligent Systems (Cyber), pp. 141-145, DOI: 10.1109/cyber.2016.7574811, .
[4] C.-H. Luo, Y.-F. Chung, C.-C. Yeh, "Stringlike pulse quantification study by pulse wave in 3D pulse mapping," The Journal of Alternative and Complementary Medicine, vol. 18 no. 10, pp. 924-931, DOI: 10.1089/acm.2012.0047, 2012.
[5] Y.-F. Chung, C.-S. Hu, C.-C. Yeh, C.-H. Luo, "How to standardize the pulse-taking method of traditional Chinese medicine pulse diagnosis," Computers in Biology and Medicine, vol. 43 no. 4, pp. 342-349, DOI: 10.1016/j.compbiomed.2012.12.010, 2013.
[6] Y.-W. Chu, C.-H. Luo, Y.-F. Chung, C.-S. Hu, C.-C. Yeh, "Using an array sensor to determine differences in pulse diagnosis-Three positions and nine indicators," European Journal of Integrative Medicine, vol. 6 no. 5, pp. 516-523, DOI: 10.1016/j.eujim.2014.04.003, 2014.
[7] C.-H. Luo, C.-J. Su, T.-Y. Huang, C.-Y. Chung, "Non-invasive holistic health measurements using pulse diagnosis: I. Validation by three-dimensional pulse mapping," European Journal of Integrative Medicine, vol. 8 no. 6, pp. 921-925, DOI: 10.1016/j.eujim.2016.06.017, 2016.
[8] J. Cui, L.-P. Tu, J.-F. Zhang, S.-L. Zhang, Z.-F. Zhang, J.-T. Xu, "Analysis of pulse signals based on array pulse volume," Chinese Journal of Integrative Medicine, vol. 25 no. 2, pp. 103-107, DOI: 10.1007/s11655-018-2776-y, 2019.
[9] C. J. Su, T. Y. Huang, C. H. Luo, "Arterial pulse analysis of multiple dimension pulse mapping by local cold stimulation for arterial stiffness," IEEE Sensors Journal, vol. 16 no. 23, pp. 8288-8294, DOI: 10.1109/JSEN.2016.2582805, 2016.
[10] C.-H. Luo, J.-W. Ye, C.-Y. Lin, T.-L. Lee, L.-M. Tsai, M.-D. Shieh, "L-cube polynomial for the recognition of normal and hypertensive string-like pulse mappings in Chinese medicine," Informatics in Medicine Unlocked, vol. 12, pp. 27-33, DOI: 10.1016/j.imu.2018.05.006, 2018.
[11] J. Y. A. Foo, "Use of independent component analysis to reduce motion artifact in pulse transit time measurement," IEEE Signal Processing Letters, vol. 15, pp. 124-126, DOI: 10.1109/lsp.2007.912976, 2008.
[12] H. F. Yang, Q. Zhou, J. Xiao, "Relationship between vascular elasticity and human pulse waveform based on FFT analysis of pulse waveform with different age," Proceedings of the 2009 3rd International Conference on Bioinformatics and Biomedical Engineering, vol. 1–11, pp. 254-257, DOI: 10.1109/icbbe.2009.5163297, .
[13] B. Thakker, A. L. Vyas, "Frequency domain analysis of radial pulse in abnormal health conditions," Proceedings of the 2010 IEEE EMBS Conference on Biomedical Engineering and Sciences (IECBES), pp. 227-231, .
[14] Y. Y. L. Wang, T. L. Hsu, M. Y. Jan, "Theory and applications of the harmonic analysis of arterial pressure pulse waves," Journal of Medical and Biological Engineering, vol. 30 no. 3, pp. 125-131, 2010.
[15] M. Saito, M. Matsukawa, T. Asada, Y. Watanabe, "Noninvasive assessment of arterial stiffness by pulse wave analysis," IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, vol. 59 no. 11, pp. 2411-2419, DOI: 10.1109/tuffc.2012.2473, 2012.
[16] A. C. Tang, J. W. Chung, T. K. Wong, "Validation of a novel traditional Chinese medicine pulse diagnostic model using an artificial neural network," Evidence-Based Complementary and Alternative Medicine, vol. 2012,DOI: 10.1155/2012/685094, 2012.
[17] D.-G. Jang, S.-H. Park, M. Hahn, "Enhancing the pulse contour analysis-based arterial stiffness estimation using a novel photoplethysmographic parameter," IEEE Journal of Biomedical and Health Informatics, vol. 19 no. 1, pp. 256-262, DOI: 10.1109/jbhi.2014.2306679, 2015.
[18] S. Emrani, T. S. Saponas, D. Morris, "A novel framework for pulse pressure wave analysis using persistent homology," IEEE Signal Processing Letters, vol. 22 no. 11,DOI: 10.1109/lsp.2015.2441068, 2015.
[19] C. Fischer, B. Domer, T. Wibmer, T. Penzel, "An algorithm for real-time pulse waveform segmentation and artifact detection in photoplethysmograms," IEEE Journal of Biomedical and Health Informatics, vol. 21 no. 2, pp. 372-381, DOI: 10.1109/jbhi.2016.2518202, 2017.
[20] R. Guo, Y. Wang, H. Yan, "Analysis and recognition of traditional Chinese medicine pulse based on the hilbert-huang transform and random forest in patients with coronary heart disease," Evidence-Based Complementary and Alternative Medicine, vol. 2015,DOI: 10.1155/2015/895749, 2015.
[21] X. J. Hu, L. Zhang, J. T. Xu, "Pulse wave cycle features analysis of different blood pressure grades in the elderly," Evidence-Based Complementary and Alternative Medicine, vol. 2018,DOI: 10.1155/2018/1976041, 2018.
[22] Y. N. Tsai, Y. C. Huang, S. J. Lin, "Different harmonic characteristics were found at each location on TCM radial pulse diagnosis by spectrum analysis," Evidence-Based Complementary and Alternative Medicine, vol. 2018,DOI: 10.1155/2018/9018271, 2018.
[23] M. A. Motin, C. K. Karmakar, M. Palaniswami, "Selection of empirical mode decomposition techniques for extracting breathing rate from PPG," IEEE Signal Processing Letters, vol. 26 no. 4, pp. 592-596, DOI: 10.1109/lsp.2019.2900923, 2019.
[24] Y. C. Huang, Y. H. Chang, S. M. Cheng, "Applying pulse spectrum analysis to facilitate the diagnosis of coronary artery disease," Evidence-Based Complementary and Alternative Medicine, vol. 2019,DOI: 10.1155/2019/2709486, 2019.
[25] D. A. McDonald, "The relation of pulsatile pressure to flow in arteries," The Journal of Physiology, vol. 127 no. 3, pp. 533-552, DOI: 10.1113/jphysiol.1955.sp005275, 1955.
[26] J. R. Womersley, "Method for the calculation of velocity, rate of flow and viscous drag in arteries when the pressure gradient is known," The Journal of Physiology, vol. 127 no. 3, pp. 553-563, DOI: 10.1113/jphysiol.1955.sp005276, 1955.
[27] E. O. Attinger, A. Anné, D. A. McDonald, "Use of Fourier series for the analysis of biological systems," Biophysical Journal, vol. 6 no. 3, pp. 291-304, DOI: 10.1016/s0006-3495(66)86657-2, 1966.
[28] J. A. Staessen, R. Fagard, L. Thijs, A. Amery, "Fourier analysis of blood pressure profiles," American Journal of Hypertension, vol. 6 no. 2, pp. 184S-187S, DOI: 10.1093/ajh/6.6.184s, 1993.
[29] K. A. Reddy, B. George, V. J. Kumar, "Use of fourier series analysis for motion artifact reduction and data compression of photoplethysmographic signals," Ieee Transactions on Instrumentation and Measurement, vol. 58 no. 5, pp. 1706-1711, DOI: 10.1109/tim.2008.2009136, 2009.
[30] C. W. Chang, J. M. Chen, W. K. Wang, "Development of a standard protocol for the harmonic analysis of radial pulse wave and assessing its reliability in healthy humans," Ieee Journal of Translational Engineering in Health and Medicine-Jtehm, vol. 3,DOI: 10.1109/jtehm.2015.2490661, 2015.
[31] D. E. Dick, J. E. Kendrick, G. L. Matson, V. C. Rideout, "Measurement of nonlinearity in the arterial system of the dog by a new method," Circulation Research, vol. 22 no. 2, pp. 101-111, DOI: 10.1161/01.res.22.2.101, 1968.
[32] Z. Fei, Contemporary Sphygmology in Traditional Chinese Medicine, 2003. in Chinese
[33] J. Cui, Z.-F. Fei, Z.-F. Zhang, "Classification parameter range of pulse graphs of normal pulse, slippery pulse and taut pulse," Shanghai Journal of Traditional Chinese Medicine, vol. 12, 2016.
[34] X. Li, Z. Y. Fu, P. Qian, "Computerized wrist pulse signal diagnosis using gradient boosting decision tree," Proceedings 2018 IEEE International Conference on Bioinformatics and Biomedicine (BIBM), pp. 1941-1947, DOI: 10.1109/BIBM.2018.8621391, .
[35] L. J. Qiao, Z. Qi, L. P. Tu, "The association of radial artery pulse wave variables with the pulse wave velocity and echocardiographic parameters in hypertension," Evidence-Based Complementary and Alternative Medicine, vol. 2018,DOI: 10.1155/2018/5291759, 2018.
[36] D. L. Wood, S. G. Sheps, L. R. Elveback, A. Schirger, "Cold pressor test as a predictor of hypertension," Hypertension, vol. 6 no. 3, pp. 301-306, DOI: 10.1161/01.hyp.6.3.301, 1984.
[37] M. A. Sanchez-Gonzalez, R. W. May, P. C. Brown, A. P. Koutnik, F. D. Fincham, "Depressive symptoms contribute to increased wave reflection during cold pressor test in young adult men," American Journal of Hypertension, vol. 26 no. 6, pp. 778-783, DOI: 10.1093/ajh/hpt012, 2013.
[38] C.-Y. Chung, Y.-W. Cheng, C.-H. Luo, "Neural network study for standardizing pulse-taking depth by the width of artery," Computers in Biology and Medicine, vol. 57, pp. 26-31, DOI: 10.1016/j.compbiomed.2014.10.016, 2015.
[39] L. Xu, D. Zhang, K. Wang, N. Li, X. Wang, "Baseline wander correction in pulse waveforms using wavelet-based cascaded adaptive filter," Computers in Biology and Medicine, vol. 37 no. 5, pp. 716-731, DOI: 10.1016/j.compbiomed.2006.06.014, 2007.
[40] S. McKinley, M. Levine, "Cubic spline interpolation," College of the Redwoods, vol. 45 no. 1, pp. 1049-1060, 1998.
[41] D. A. McDonald, Blood Flow in Arteries, 1974.
[42] C. Vlachopoulos, M. O’Rourke, W. W. Nichols, McDonald’s Blood Flow in Arteries: Theoretical, Experimental and Clinical Principles, 2011.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Copyright © 2019 Bo Peng et al. This is an open access article distributed under the Creative Commons Attribution License (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License. http://creativecommons.org/licenses/by/4.0/
Abstract
In this article, a three-dimensional pulse image (3DPI) instead of a one-dimensional temporal pulse wave is studied to elucidate its spatiotemporal characteristics. To check the spatial and temporal properties of 3DPI, adopted is Fourier series, in which a ratio (r) is defined as one amplitude divided by the sum of the first three amplitudes of harmonics. A ratio sequence is constituted from 70 to 90 ratios in a heartbeat with 70–90 3DPIs by sampling. Twenty-four subjects (14 males and 10 females with age of 22.2 ± 3.7 years, 20.4 ± 1.4 BMI, and 112.1 ± 4.7 mmHg systolic blood pressure) are involved in this research. There are significant statistical differences in the groups of the normal, taut, and slippery 3DPIs by the first harmonic ratio average (
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Details






1 Department of Electrical Engineering, National Cheng Kung University, Tainan 70101, Taiwan
2 School of Data and Computer Science, Sun Yat-Sen University (East Campus), Guangzhou 510006, China
3 School of Medical Engineering, Foshan University, Foshan 528000, China