Introduction
Back pain is considered one of the most common musculoskeletal disorders (MSDs) among dentists (Finsen, Christensen & Bakke, 1998). Recent studies show that 80% of the general population and over 60% of dentists will suffer back pain during their professional life (Hayes, Cockrell & Smith, 2009; Dajpratham et al., 2010; De Bruyne et al., 2016). According to these authors, higher levels of muscle activity, a strained posture and repetitive movements are the most recognized risk factors for developing MSDs (Biswas et al., 2012; Tran et al., 2016).
In the field of dentistry, a number of strategies have been recommended to reduce the incidence of musculoskeletal pain, such as reducing work time and fatigue (Thakar et al., 2015), limiting the workspace (Custódio, Silva & Brandão, 2012), alternating standing with sitting time (Pîrvu et al., 2014), working with dental assistants (Gosavi, Gosavi & Jawade, 2012), increasing physical activity and stretching (Gosavi, Gosavi & Jawade, 2012; Kumar et al., 2014). Most recently, different ergonomic supports, such as the ergonomic stool and magnification lenses seem to be the most common solutions used by dentists (Branson et al., 2004; Valachi, 2009; Haddad et al., 2012; Tran et al., 2016; De Sio et al., 2018).
Multiple outcome measures have been used to date to demonstrate the utility of the ergonomic stool (Haddad et al., 2012; Tran et al., 2016; De Bruyne et al., 2016) and magnification lenses (Branson et al., 2004; Hayes et al., 2014, 2016; Dable et al., 2014; Rafie et al., 2015), such as pain assessments and functional scales (Hayes et al., 2016), perceived fatigue (Rolander et al., 2005; Ranavolo et al., 2018), motion analysis (Branson et al., 2004; Silva et al., 2016), postural assessment (Branson et al., 2004; Haddad et al., 2012; Dable et al., 2014) and muscle activity (Gandavadi, 2008; Tran et al., 2016; De Bruyne et al., 2016). Surface electromyography (sEMG) is the most extensively used device to describe muscle activity in daily dental work (Rolander et al., 2005; Blanc, Farre & Hamel, 2014). Despite this, very few studies have used sEMG as an outcome measure to analyze the effect of ergonomic supports such as the ergonomic stool on back muscles (Haddad et al., 2012; Tran et al., 2016; De Bruyne et al., 2016), and, according to our research, no studies have focused specifically on the effect of magnification lenses. Consequently, to our knowledge, there are no studies that compare the effect of magnification lenses and ergonomic stool, separately, or combined in muscle activation patterns in the middle and low back muscles. In the present study, we evaluated the influence of different ergonomic supports (ergonomic stool and magnification lenses) on the muscle sEMG activity of two trunk muscles during a posterior composite restoration procedure.
Materials and Methods Study design
We used a one-way repeated measures design. Using a portable sEMG recorder, we measured the muscle activity of two trunk muscles: the medium trapezius (MT) from the dominant upper extremity and the lumbar erector spinae (LES). This procedure was carried out while participants performed three tasks of a posterior composite restoration procedure on a phantom head: tooth drilling, tooth filling and tooth polishing. All participants performed these tasks, first without ergonomic support (baseline measures), and then using three different ergonomic supports with 15 min of rest time between each task. The order in which these different ergonomic supports were used was randomized. Similarly, the order in which each of the tasks were executed was also randomized. In order to examine the reliability of sEMG measures during each task, we also used a test–retest design for the baseline condition using a subsample of participants who completed two sessions, 30 min apart.
Participants
Thirty-six dentists were recruited (n = 36) among post-graduate students and professors of the University of Murcia. Eligible participants were aged 60 years old or less and without self-reported health MSDs in the back, neck and upper limbs. The exclusion criteria were visual acuity problems, previous surgery, medication that may affect the eyes or an inability to wear glasses/prisms. All participants gave written informed consent. This study obtained approval from the Ethics Committee of the University of Murcia (approval No. 986/2014).
Instrumentation
All dental tasks (and associated sEMG measures) were performed on a simulated dental Workstation comprised of a dental chair with adjustable height and an operating lamp Kavo Primus 2058® (Kavo Dental GmbH, Biberach, Germany), a phantom head and dental model KavoG-50 Jaw simulator® (Kavo Dental GmbH, Biberach, Germany) and a conventional stool. Dental materials (e.g., composite) and the dental tools were provided by the researchers. The ergonomic supports used to generate the different conditions were an ergonomic stool with adjustable lumbar support MO Sit Up Balance Op Chair® (MeridentOptergo AB, Mölnlycke, Sweden) and magnification lenses MO Ultralight Flip-up Prism solutions® (MeridentOptergo AB, Mölnlycke, Sweden). These lenses are a novel telemicroscope that provides an increase of 2.5, while the inclination of the lens and the frame provides a correct angle of vision without the need to tilt the head.
Electrical muscle activity of the MT and LES were recorded during the dental tasks using sEMG. A laboratory system, the data-LINK900 software v.7.5 (Biometrics Ltd, Newport, UK), was used. Three active SX230 sEMG sensors (Biometrics Ltd, Newport, UK) were employed for the measurements. sEMG bipolar electrodes were placed on the appropriate locations, using double-sided die-cut tapes provided by the manufacturer. All sEMG signals were amplified and sampled at 1,000 Hz. Raw bipolar Electromyography (EMG) data were processed by using the root-mean-square with 50 ms and 64 Hz filter.
Procedures
Each participant was evaluated on two separate days, 1 week apart. On the first day, demographic and anthropometric characteristics were obtained by self-report. Additionally, the participants received a talk on ergonomics and the use of magnification lenses and the ergonomic stool. Finally, a professional optician adapted the prismatic glasses to individually fit each dentist, so that participants could become accustomed to using these during the week prior to the data collection of muscle activity.
On the second day, data collection was divided into three phases: preparation, baseline recording and experimental records. First, subjects were led to a simulated dental workstation for the application of the sEMG electrodes. The skin over the muscles was cleaned with alcohol. SX230 sensors were placed parallel to the fibers of the selected muscles with double-sided adhesive tape according to the anatomical locations recommended by SENIAM and Motmans, Tomlow & Vissers (2006) (Fig. 1). A ground electrode was placed on the wrist.
Figure 1: Electrode placement for Lumbar Erector Spinae. DOI: 10.7717/peerj.8028/fig-1
To normalize the data obtained, three maximum voluntary isometric contractions (MVICs) of each measured muscle were recorded following a muscle testing procedure. The maximum and mean amplitudes of the sEMG obtained during the functional exercises was then normalized with the highest value of the MVIC and expressed as a percentage of MVIC (% MVIC). This procedure requires three maximal resisted voluntary contractions, performed in the sitting position and in the following order: scapular retraction for MT and lumbar extension for LES. After the collection of the maximum contractions, the participants were allowed to rest for 10 min before commencing the baseline recording.
Prior to recording the measurements, the starting position on the workstation was standardized as follows: the dentist sat next to the doll in a manner that enabled an approach via their dominant side, the feet were separated and placed on the floor, the knees were flexed at 90°, the angle between the lumbar spine and the femur was 110° to avoid rectification of lordosis, the back was straight, the shoulders were parallel to the horizontal plane with the arms and elbows attached to the body. Although all dentists started from the same starting position, they were allowed to adopt their usual posture once the measurement began.
The sEMG baseline recordings were established for each subject while performing the tasks in normal conditions with a conventional stool. The experimental records were established for each of the three different ergonomic conditions (ergonomic stool, magnification lenses and both). Both baseline and experimental EMG measures were averaged for each task, condition and muscle group, and then normalized by their respective MVIC.
Statistical analysis
IBM SPSS® statistics v.23.0 (IBM, Chicago, IL, USA) was used for statistical analysis. The relative test–retest reliability was evaluated using intraclass correlation coefficients (ICCs), and the absolute reliability was measured using standard error of measurement (SEM). The SEM was presented in absolute reliability terms and as a SEM% by dividing the SEM with the average of the test and retest values. A repeated measures analysis of variance (ANOVA) was used to determine the mean differences in sEMG values for each muscle group between the four ergonomic conditions (conventional stool, ergonomic stool, magnification lenses, ergonomic stool and magnification lenses). In addition, we performed multiple post hoc comparisons tests between the ergonomic conditions to determine which conditions were significantly different from others. For this, we used the Bonferroni t-test. We used a significance level of α < 0.05 for all analyses.
Sample size calculations were based on one group being measured across four observations. Using an alpha of 0.05, a power of 0.80 and an estimated moderate treatment effect of 0.03 (partial eta-squared), the necessary sample size (n) was estimated to be a minimum of 36 participants, in order to detect a significant treatment effect.
Results
A total of 36 participants completed all of the tasks with all the ergonomic supports. Their ages ranged from 20 to 59 (39.5 ± 19.5) years old. Of these, 26 (72.2%) participants were included in the test–retest reliability study. In this reliability study, participants and non-participants did not differ with regards to sex (p = 0.178 and p = 0.425, respectively), age (p = 0.953; p = 0.310) and education level (p = 0.365; p = 0.067).
The reliability of the sEMG measurements for each muscle and task is presented in Table 1. All measurements showed excellent ICCs, and all their confidence intervals had a lower limit that was higher than 0.6. The SEM was under 10%. All muscles showed a comparable measurement error between the different tasks.
Muscle | Task | ICC (95% CI) | SEM | %SEM |
---|---|---|---|---|
MT | TD | 0.994 [0.987–0.997] | 0.04 | 3.3 |
TF | 0.962 [0.917–0.983] | 0.05 | 8.8 | |
TP | 0.999 [0.998–1.000] | 0.003 | 1.3 | |
LES | TD | 0.999 [0.998–1.000] | 0.002 | 1.3 |
TF | 0.992 [0.984–0.996] | 0.06 | 4.3 | |
TP | 0.997 [0.994–0.998] | 0.02 | 2.4 |
DOI: 10.7717/peerj.8028/table-1
Note:
MT, medium trapezius; LES, lumbar erector spinae; TD, tooth drilling; TF, tooth filling; TP, tooth polishing; ICC, intraclass correlation coefficient; SEM, standard error of measurement.
Table 2 shows the mean sEMG values (and SD) expressed as a percentage of MVIC for each of four ergonomic conditions and the three tasks. The results of the one-way repeated measures ANOVA showed that the muscle activity of MT differed significantly across the four ergonomic conditions in the three tasks (F = 46.77 (p < 0.001), F = 40.14 (p < 0.001), F = 49.83 (p < 0.001), respectively). The Bonferroni post hoc tests showed that the MT had more muscle activity in the condition with the ergonomic stool compared to each one of the other conditions (p < 0.001) in the three tasks. Moreover, the difference among these three conditions also reached significance (p < 0.001).
Muscle | Task | CS Mean (SD) | ES Mean (SD) | ML Mean (SD) | ES and ML Mean (SD) | Significance | ||
---|---|---|---|---|---|---|---|---|
Wilks’ lambda | F Statistic | p-value | ||||||
MT | TD | 6.41 (3.65) | 8.66 (4.91) | 4.20 (2.42) | 3.56 (2.00) | 0.190 | F3.33 = 46.77 | <0.001 |
TF | 5.98 (3.35) | 10.04 (5.66) | 2.58 (1.47) | 3.57 (2.00) | 0.215 | F3.33 = 40.14 | <0.001 | |
TP | 5.82 (3.27) | 8.17 (4.60) | 2.63 (1.54) | 5.43 (3.06) | 0.181 | F3.33 = 49.83 | <0.001 | |
LES | TD | 6.06 (4.25) | 8.35 (5.86) | 4.57 (3.08) | 7.42 (5.16) | 0.265 | F3.33 = 30.52 | <0.001 |
TF | 7.44 (5.20) | 5.53 (3.69) | 4.41 (2.99) | 7.51 (5.22) | 0.284 | F3.33 = 27.66 | <0.001 | |
TP | 5.70 (4.01) | 8.71 (6.12) | 0.92 (0.62) | 7.42 (5.12) | 0.268 | F3.33 = 30.04 | <0.001 |
DOI: 10.7717/peerj.8028/table-2
Note:
MT, medium trapezius; LES, lumbar erector spinae; TD, tooth drilling; TF, tooth filling; TP, tooth polishing; CS, conventional stool; ES, ergonomic stool; ML, magnification lenses.
Figure 2A depicts the pattern of change between these three conditions (conventional stool, ergonomic stool, magnification lenses, and ergonomic stool and magnification lenses), which was similar for the three tasks. Moreover, this figure displays how the lowest muscle activity of MT occurred when participants used the magnification lenses. Figure 3A shows the percentage of change of the ergonomic supports regarding the conventional stool in order to quantify patterns of change. Additionally, for all three tasks, magnification lenses and the combination (the ergonomic stool and magnification lenses) reduced MT muscle activity in a range between 6.7% and 56.8%, while the isolated use of the ergonomic stool increased muscle activity.
Figure 2: Mean of muscle activity for medium trapezius (A) and lumbar erector spinae (B) in different ergonomic conditions and tasks. MT, medium trapezius; LES, lumbar erector spinae; TD, tooth drilling; TF, tooth filling; TP, tooth polishing. DOI: 10.7717/peerj.8028/fig-2
Figure 3: Percentage of change in muscle activity of (A) medium trapezius and (B) lumbar erector spine (reference: conventional stool) by ergonomic support. ES, ergonomic stool; ML, magnification lenses; ES & ML, ergonomic stool and magnification lenses; TD, tooth drilling; TF, tooth filling; TP, tooth polishing. DOI: 10.7717/peerj.8028/fig-3
Concerning the LES, we obtained a different main effect of the ergonomic conditions on muscle activity in the three tasks (Table 2). Bonferroni post hoc tests also showed differences between the three ergonomic supports (p < 0.001). However, the difference between the conventional stool and the ergonomic stool showed a different pattern regarding LES activation for the tooth filling task (Fig. 2B). The muscle activity of LES using the ergonomic stool was significantly higher than using the conventional stool alone for the tooth drilling and tooth polishing tasks (8.35 vs. 6.06 (p < 0.001) and 8.71 vs. 5.70 (p < 0.001), respectively). However, this muscle showed a significant decrease of activity during the tooth filling task (5.53 vs. 7.44). Furthermore, the muscle activity of the LES using magnification lenses was lower in all three tasks compared to using the conventional stool, ergonomic stool, and ergonomic stool and magnification lenses.
Figures 3A and 3B display and quantify all these patterns of change compared to the conventional stool. These figures also show how the magnification lenses were able to reduce LES muscle activity during the three tasks (between 24% and 74%).
Discussion
This is the first study to evaluate the effect of different ergonomic supports on the muscle activity of the back muscles. Our findings show that magnification lenses are effective for decreasing the muscle activity of MT and LES during the three tasks of posterior composite restoration, compared to standard practice using the conventional stool. However, we observed a tendency for the opposite effect to occur with the use of the ergonomic stool or the combination of the same with magnification lenses (ergonomic stool and magnification lenses), by increasing the muscle activity in almost all tasks performed. This means that the increased muscle activity that occurs with the ergonomic stool is not modified by use of the magnification lenses, when used together with the stool in the case of the LES muscles.
Our sEMG results can only be partially compared with previous studies. In fact, few studies (Tran et al., 2016; De Bruyne et al., 2016) have evaluated the muscle activity of LES associated to the ergonomic stool. The ergonomic stool increases LES muscle activation during both the tooth drilling and tooth polishing tasks. However, these findings contradict those reported by other authors. A possible explanation for this could be that these authors used a different type of stool than that used in the study. While Tran et al. (2016) used a conventional chair incorporating a chest support, De Bruyne et al. (2016) used two different chairs, thus modifying hip flexion.
We agree with most authors who have found that the ergonomic stool generates a significantly decreased spinal flexion (Haddad et al., 2012; De Bruyne et al., 2016), improving dentists’ posture. However, the increase in muscle activation detected in our study supports the idea that optimal posture requires active maintenance of the physiological lumbar lordosis, and, therefore, higher levels of activation of LES and MT.
The use of magnification lenses produced the lowest levels of muscle activity in the MT. According to several authors, these prismatic lenses enable a better field of vision without the need to bend forward as much, leading to less strain. This may allow dentists to reduce neck flexion and adopt a more upright posture (Lindegård, Gustafsson & Hansson, 2012; Plessas & Bernardes Delgado, 2018). However, to date, no studies differentiate the posture generated by the magnification lenses and the ergonomic stool.
According to our results, the combination of the ergonomic stool and magnification lenses was similar with regards the muscle activity of MT compared to isolated use of magnification lenses in two of the three tasks. A possible reason for this could be a positive moderating effect on the posture from using the magnification lenses. In other words, the isolated use of the ergonomic stool generates an increase in muscle activation of MT, this effect is then mitigated by the combined action of magnification lenses. In our opinion, this surprising effect cannot be attributed to measurement errors because we found very reliable measures in our preliminary study (Table 1) with a percentage of standard error below 10%. Although we were unable to find reliability studies of the sEMG in this population, our results reveal that the sEMG is a reliable tool for measuring muscle activity of the back in dentists.
Regarding the muscle activity of the LES, a clear pattern of change was not observed between the different ergonomic supports. Only the use of magnification lenses produced a clear decrease in muscle activity. The effect of the ergonomic stool and the combination of the ergonomic stool and magnification lenses was higher compared to the conventional stool in two of the three tasks. These findings highlight the fact that the ergonomic stool requires the maintenance of lumbar lordosis, increasing the muscular activity of the LES during dental procedures.
This study has several strengths. First, our experimental protocol was similar to previous work, which facilitated comparison. Thus, participants used a simulated workstation with a phantom head model and were positioned in an ergonomic position with an ideal working distance; moreover, all prior studies allowed for rest periods between tasks to avoid exhaustion and used the MVIC to relativize the data obtained by the sEMG (Haddad et al., 2012; Tran et al., 2016; De Bruyne et al., 2016). Second, our sample size was greater than previous studies, such as Haddad et al. (2012), De Bruyne et al. (2016) and Tran et al. (2016) (using n < 30). Third, while these previous researchers used brief sEMG recording times (ranged from 20 to 30 s), we performed uninterrupted measurements of the entire task (180 s). In our opinion, these measures may be more representative of the reality of dentists’ daily work.
A limitation of the present study was that we did not collect the postural changes of dentists during tasks, as our only outcome measure was muscular activity. Another limitation was that the sEMG activity of MT and LES was only recording on the dominant side and no inference can therefore be made regarding the contraction pattern of muscles investigated on the non-dominant side.
Conclusions
In conclusion, this study found that the ergonomic stool increases the muscle activity of MT and LES muscles to a greater degree compared to magnification lenses. The combination of the ergonomic stool and magnification lenses produces a different effect on the activity of both muscle groups. For the LES muscles, although the combination of supports leads to a similar muscle activation compared to the isolated use of the ergonomic stool (use of magnification lenses does not generate a change), in the MT muscle, the prevailing effect is that of the magnification lenses, as the ergonomic stool did not lead to changes.
The posture adopted by dentists may be different in these two ergonomic supports, therefore the use of these should not be generalized. A comprehensive analysis of the posture adopted by dentists in their working environment in needed to implement specific ergonomic measures. Future studies may want to expand the research to include other effects of ergonomic supports on muscle activity in different tasks, as well as possible interactions between the same.
Supplemental Information
Raw data.
DOI: 10.7717/peerj.8028/supp-1
Download
Additional Information and Declarations
Competing Interests
The authors declare that they have no competing interests.
Author Contributions
Manuel López-Nicolás conceived and designed the experiments, contributed reagents/materials/analysis tools, authored or reviewed drafts of the paper, approved the final draft.
José A. García-Vidal conceived and designed the experiments, performed the experiments, analyzed the data, prepared figures and/or tables, approved the final draft.
Francesc Medina-Mirapeix conceived and designed the experiments, analyzed the data, authored or reviewed drafts of the paper, approved the final draft.
Joaquín P. Sánchez-Onteniente performed the experiments, contributed reagents/materials/analysis tools, prepared figures and/or tables, approved the final draft.
Juan D. Berná Mestre analyzed the data, authored or reviewed drafts of the paper, approved the final draft.
Rodrigo Martín-San Agustín analyzed the data, prepared figures and/or tables, approved the final draft.
María P. Escolar-Reina performed the experiments, authored or reviewed drafts of the paper, approved the final draft.
Human Ethics
The following information was supplied relating to ethical approvals (i.e., approving body and any reference numbers):
This study obtained approval from the Ethics Committee of the University of Murcia (approval No. 986/2014).
Clinical Trial Ethics
The following information was supplied relating to ethical approvals (i.e., approving body and any reference numbers):
The University of Murcia granted Ethical approval to carry out the study within its facilities (Ethical Application Ref: 986/2014).
Clinical Trial Registration
The following information was supplied regarding Clinical Trial registration:
The University of Murcia granted this study with Ref: 986/2014.
Data Availability
The following information was supplied regarding data availability:
The raw measurements are available in the Supplemental File.
Funding
The authors received no funding for this work.
Biswas R, Sachdev V, Jindal V, Ralhan S. 2012. Musculoskeletal disorders and ergonomic risk factors in dental practice. Indian Journal of Dental Sciences 4:70-74
Blanc D, Farre P, Hamel O. 2014. Variability of musculoskeletal strain on dentists: an electromyographic and goniometric study. International Journal of Occupational Safety and Ergonomics 20(2):295-307
Branson BG, Bray KK, Gadbury-Amyot C, Holt LA, Keselyak NT, Mitchell TV, Williams KB. 2004. Effect of magnification lenses on student operator posture. Journal of Dental Education 68(3):384-389
Custódio RAR, Silva CES, Brandão JGT. 2012. Ergonomics work analysis applied to dentistry - a Brazilian case study. Work 41(Suppl 1):690-697
Dable RA, Wasnik PB, Yeshwante BJ, Musani SI, Patil AK, Nagmode SN. 2014. Postural assessment of students evaluating the need of ergonomic seat and magnification in dentistry. Journal of Indian Prosthodontic Society 14(S1):51-58
Dajpratham P, Ploypetch T, Kiattavorncharoen S, Boonsiriseth K. 2010. Prevalence and associated factors of musculoskeletal pain among the dental personnel in a dental school. Journal of the Medical Association of Thailand = Chotmaihet Thangphaet 93(6):714-721
De Bruyne MAA, Van Renterghem B, Baird A, Palmans T, Danneels L, Dolphens M. 2016. Influence of different stool types on muscle activity and lumbar posture among dentists during a simulated dental screening task. Applied Ergonomics 56:220-226
De Sio S, Traversini V, Rinaldo F, Colasanti V, Buomprisco G, Perri R, Mormone F, La Torre G, Guerra F. 2018. Ergonomic risk and preventive measures of musculoskeletal disorders in the dentistry environment: an umbrella review. PeerJ 6(5):e4154
Finsen L, Christensen H, Bakke M. 1998. Musculoskeletal disorders among dentists and variation in dental work. Applied Ergonomics 29(2):119-125
Gandavadi A. 2008. Working postures in dental practitioners and dental students: relationships between posture, seating, and muscle activity. Ph.D. thesis, University of Birmingham
Gosavi SS, Gosavi SY, Jawade RS. 2012. Posturedontics: reducing the stress in dentistry. World Journal of Dentistry 3(4):335-339
Haddad O, Sanjari MA, Amirfazli A, Narimani R, Parnianpour M. 2012. Trapezius muscle activity in using ordinary and ergonomically designed dentistry chairs. International Journal of Occupational and Environmental Medicine 3(2):76-83
Hayes MJ, Cockrell D, Smith DR. 2009. A systematic review of musculoskeletal disorders among dental professionals. International Journal of Dental Hygiene 7(3):159-165
Hayes MJ, Osmotherly PG, Taylor JA, Smith DR, Ho A. 2014. The effect of wearing loupes on upper extremity musculoskeletal disorders among dental hygienists. International Journal of Dental Hygiene 12(3):174-179
Hayes MJ, Osmotherly PG, Taylor JA, Smith DR, Ho A. 2016. The effect of loupes on neck pain and disability among dental hygienists. Work 53(4):755-762
Kumar DK, Rathan N, Mohan S, Begum M, Prasad B, Prasad ERV. 2014. Exercise prescriptions to prevent musculoskeletal disorders in dentists. Journal of Clinical and Diagnostic Research 8:ZE13-ZE16
Lindegård A, Gustafsson M, Hansson G-Å. 2012. Effects of prismatic glasses including optometric correction on head and neck kinematics, perceived exertion and comfort during dental work in the oral cavity – a randomised controlled intervention. Applied Ergonomics 43(1):246-253
Motmans RREE, Tomlow S, Vissers D. 2006. Trunk muscle activity in different modes of carrying schoolbags. Ergonomics 49(2):127-138
Pîrvu C, Pătraşcu I, Pîrvu D, Ionescu C. 2014. The dentist’s operating posture - ergonomic aspects. Journal of Medicine and Life 7(2):177-182
Plessas A, Bernardes Delgado M. 2018. The role of ergonomic saddle seats and magnification loupes in the prevention of musculoskeletal disorders. A systematic review. International Journal of Dental Hygiene 16(4):430-440
Rafie F, Zamani Jam A, Shahravan A, Raoof M, Eskandarizadeh A. 2015. Prevalence of upper extremity musculoskeletal disorders in dentists: symptoms and risk factors. Journal of Environmental and Public Health 2015(4):1-6
Ranavolo A, Chini G, Silvetti A, Mari S, Serrao M, Draicchio F. 2018. Myoelectric manifestation of muscle fatigue in repetitive work detected by means of miniaturized sEMG sensors. International Journal of Occupational Safety and Ergonomics 24(3):464-474
Rolander B, Jonker D, Karsznia A, Öberg T. 2005. Evaluation of muscular activity, local muscular fatigue, and muscular rest patterns among dentists. Acta Odontologica Scandinavica 63(4):189-195
Silva V, Fonseca P, Pinho ME, Góis J, Vaz M, Reis-Campos J. 2016. Biomechanical study of dentists posture when using a conventional chair versus a saddle-seat chair. Revista Portuguesa de Estomatologia, Medicina Dentária e Cirurgia Maxilofacial 58(1):39-45
Thakar S, Shivlingesh K, Jayaprakash K, Gupta B, Gupta N, Anand R, Motghare V, Prabhakar I. 2015. High levels of physical inactivity amongst dental professionals: a questionnaire based cross sectional study. Journal of Clinical and Diagnostic Research 9:ZC43-ZC46
Tran V, Turner R, MacFadden A, Cornish SM, Esliger D, Komiyama K, Chilibeck PD. 2016. A dental stool with chest support reduces lower back muscle activation. International Journal of Occupational Safety and Ergonomics 22(3):301-304
Valachi B. 2009. Magnification in dentistry: how ergonomic features impact your health. Dentistry Today 28(4):132 134, 136–137
Manuel López-Nicolás1, José A. García-Vidal2, Francesc Medina-Mirapeix2, Joaquín P. Sánchez-Onteniente3, Juan D. Berná Mestre4, Rodrigo Martín-San Agustín5, María P. Escolar-Reina2
1 Department of Dermatology, Stomatology, Radiology and Physical Medicine, University of Murcia, Murcia, Spain
2 Department of Physiotherapy, University of Murcia, Murcia, Spain
3 Department of Ophthalmology, Optometry, Otolaryngology and Pathological Anatomy, University of Murcia, Murcia, Spain
4 Department of Radiology, Virgen de la Arrixaca University Clinical Hospital, El Palmar, Spain
5 Department of Physiotherapy, University of Valencia, Valencia, Spain
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
© 2019 López-Nicolás et al. This is an open access article distributed under the terms of the Creative Commons Attribution License: https://creativecommons.org/licenses/by/4.0/ (the “License”), which permits unrestricted use, distribution, reproduction and adaptation in any medium and for any purpose provided that it is properly attributed. For attribution, the original author(s), title, publication source (PeerJ) and either DOI or URL of the article must be cited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.
Abstract
Background
The aim of this study was to evaluate the effect of different ergonomic supports on the muscle activity of two trunk muscles while a group of dentists performed a common dental procedure on a phantom head, divided into three tasks.
Methods
A one-way repeated measures study (ANOVA) was conducted on a group of 36 dentists. The middle trapezius and lumbar erector spinae muscles were measured with and without the use of different ergonomic supports (ergonomic stool, magnification lenses and both) using a portable surface electromyography (sEMG) device. Intraclass correlation coefficients (ICCs) and the absolute standard error of measurement (SEM) were used to establish the reliability of the baseline measures without ergonomic supports.
Results
The sEMG showed excellent ICCs (ranging from 0.92 to 0.99) and SEM. Bonferroni post hoc tests showed differences between the three ergonomic supports (p < 0.001) in both muscles studied. The lowest muscle activity measurement occurred with the isolated used of magnification lenses. The use of the ergonomic stool increased the muscle activity of the middle trapezius and lumbar erector spinae muscles to a greater extent than the magnification lenses. The combination of the ergonomic stool and the magnification lenses produced a different effect on each muscle.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer