It appears you don't have support to open PDFs in this web browser. To view this file, Open with your PDF reader
Abstract
Background
To optimize the fluid status of adult patients with severe malaria, World Health Organization (WHO) guidelines recommend the insertion of a central venous catheter (CVC) and a target central venous pressure (CVP) of 0-5 cmH2O. However there are few data from clinical trials to support this recommendation.
Methods
Twenty-eight adult Indian and Bangladeshi patients admitted to the intensive care unit with severe falciparum malaria were enrolled in the study. All patients had a CVC inserted and had regular CVP measurements recorded. The CVP measurements were compared with markers of disease severity, clinical endpoints and volumetric measures derived from transpulmonary thermodilution.
Results
There was no correlation between the admission CVP and patient outcome (p = 0.67) or disease severity (p = 0.33). There was no correlation between the baseline CVP and the concomitant extravascular lung water (p = 0.62), global end diastolic volume (p = 0.88) or cardiac index (p = 0.44). There was no correlation between the baseline CVP and the likelihood of a patient being fluid responsive (p = 0.37). On the occasions when the CVP was in the WHO target range patients were usually hypovolaemic and often had pulmonary oedema by volumetric measures. Seven of 28 patients suffered a complication of the CVC insertion, although none were fatal.
Conclusion
The WHO recommendation for the routine insertion of a CVC, and the maintenance of a CVP of 0-5 cmH2O in adults with severe malaria, should be reconsidered.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer