Abstract
Background
Normothermic and hypothermic oxygenated perfusion for donation after circulatory death in kidney transplantation are becoming popular in Italy, with the purpose of reducing the risk of primary non function and delayed graft function due to the prolonged warm ischemia time.
Potential complications related to these procedures are currently under investigation and are continuously emerging with the increasing experience. Post-operative infections - in particular graft arteritis - are a rare complication but determine high risk of mortality and of graft loss.
The acute onset of the arterial complications makes it very difficult to find an effective treatment, and early diagnosis is crucial for saving both patient and graft. Prevention of such infections in this particular setting are advisable.
Case presentation
We present a patient with an acute arterial rupture after transplantation of a DCD graft treated in-vivo hypothermic oxygenated perfusion. The cause was a severe arteritis of the renal artery caused by Candida krusei and Pseudomonas aeruginosa. We discussed our treatment and we compared it to the other reported series.
Conclusion
Fungal infections in DCD transplant may be treacherous and strategies to prevent them should be advocated.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer