Abstract
Background
A dysbalanced coagulation system is part of the pathological host response to infection in sepsis. Activation of pro-coagulant pathways and attenuation of anti-coagulant activity ultimately lead to microvascular stasis and consequent organ failure. No treatment approaches specifically targeting this axis are available. We explored the effects of therapeutic plasma exchange (TPE) on microvascular coagulation dysbalance in septic shock.
Methods
We conducted a prospective single-center study enrolling 31 patients with early septic shock (onset < 12 h) requiring high doses of norepinephrine (NE > 0.4 μg/kg/min). Clinical and biochemical data, including measurement of protein C; a disintegrin and metalloprotease with a thrombospondin type 1 motif, member 13 (ADAMTS13); and von Willebrand factor antigen (vWF:Ag), were obtained before and after TPE against fresh frozen plasma.
Results
Antithrombotic acting proteins such as antithrombin-III (ATIII) and protein C were markedly reduced in septic patients, but their activity increased after TPE (ATIII, 51% (41–61) vs. 63% (48–70), p = 0.029; protein C, 47% (38–60) vs. 62% (54–69), p = 0.029). Median ADAMTS13 activity was increased by TPE from 27 (21–42) % before to 47 (38–62) % after TPE (p < 0.001). In contrast, vWF:Ag was elevated and could be reduced by TPE (353 (206–492) IU/dL vs. 170 (117–232) IU/dL, p < 0.001). Regression analysis yielded a correlation between ADAMTS13 activity and platelet count (p = 0.001, R2 = 0.316).
Conclusions
Septic shock was associated with activation of pro-coagulant pathways and simultaneous depletion of anti-coagulant factors. TPE partially attenuated this dysbalance by removing pro- and by replacing anti-coagulant factors.
Trial registration
ClinicalTrials.gov, NCT03065751. Retrospectively registered on 28 February 2017.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer