Abstract
Background
Dengue is an emerging infectious disease that infects up to 390 million people yearly. The growing demand of dengue diagnostics especially in low-resource settings gave rise to many rapid diagnostic tests (RDT). This study evaluated the accuracy and utility of ViroTrack Dengue Acute - a new biosensors-based dengue NS1 RDT, SD Bioline Dengue Duo NS1/IgM/IgG combo - a commercially available RDT, and SD Dengue NS1 Ag enzyme-linked immunosorbent assay (ELISA), for the diagnosis of acute dengue infection.
Methods
This prospective cross-sectional study consecutively recruited 494 patients with suspected dengue from a health clinic in Malaysia. Both RDTs were performed onsite. The evaluated ELISA and reference tests were performed in a virology laboratory. The reference tests comprised of a reverse transcription-polymerase chain reaction and three ELISAs for the detection of dengue NS1 antigen, IgM and IgG antibodies, respectively. The diagnostic performance of evaluated tests was computed using STATA version 12.
Results
The sensitivity and specificity of ViroTrack were 62.3% (95%CI 55.6–68.7) and 95.0% (95%CI 91.7–97.3), versus 66.5% (95%CI 60.0–72.6) and 95.4% (95%CI 92.1–97.6) for SD NS1 ELISA, and 52.4% (95%CI 45.7–59.1) and 97.7% (95%CI 95.1–99.2) for NS1 component of SD Bioline, respectively. The combination of the latter with its IgM and IgG components were able to increase test sensitivity to 82.4% (95%CI 76.8–87.1) with corresponding decrease in specificity to 87.4% (95%CI 82.8–91.2). Although a positive test on any of the NS1 assays would increase the probability of dengue to above 90% in a patient, a negative result would only reduce this probability to 23.0–29.3%. In contrast, this probability of false negative diagnosis would be further reduced to 14.7% (95%CI 11.4–18.6) if SD Bioline NS1/IgM/IgG combo was negative.
Conclusions
The performance of ViroTrack Dengue Acute was comparable to SD Dengue NS1 Ag ELISA. Addition of serology components to SD Bioline Dengue Duo significantly improved its sensitivity and reduced its false negative rate such that it missed the fewest dengue patients, making it a better point-of-care diagnostic tool. New RDT like ViroTrack Dengue Acute may be a potential alternative to existing RDT if its combination with serology components is proven better in future studies.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer