1. Introduction
It is well known that the swine industry has been developing rapidly over recent years [1]. However, the improper disposal of most swine wastewater seriously affects the sustainable development of the environment and the economy [2,3]. Currently, the treatment methods of livestock wastewater mainly include the returning farmland mode, the natural mode and the factory mode, which are costly, resource wasting and lead to unavoidable secondary pollution [4]. It is particularly emergent to make swine wastewater profitable at a lower cost due to its abundance.
The advent of microbial fuel cell (MFC) has provided a solution to cope with wastewater and convert chemical energy into electric energy efficiently [5]. By suspending microorganisms in the anode chamber, MFC can degrade the complex organic compounds by the exoelectrogens attached on the anode and produce electrons, which will pass the anode and reach the cathode through the external circuit [6]. The protons produced by this anodic reaction are diffused through the isolation membrane between the anode and cathode chamber, which can combine with the electrons in the cathode chamber from an external loop to generate current [7]. However, the efficiency of MFCs is too low, which prevents it from being used widely in practice [8].
The researches into MFC have paid most attention to the materials or structure, while the microorganisms and operation environment of the MFC has been largely neglected [9,10]. It was found that the chemical oxygen demand (COD) of swine wastewater fluctuated frequently when climate changed through field sampling, which directly affected the microorganism inside MFCs [11]. Feng et al. investigated the effect of substrate concentration on MFC performance by using sodium acetate as wastewater. It was found that when the substrate concentration increased, the anode biomass and COD removal rate decreased, and the power density increased [12]. Wang et al. found that the sustaining time of current generated in MFC by using turmeric water as a substrate decreased with the increase of COD, which means excessive COD may have an inhibitory effect on microorganisms [13]. At present, most of the researches working on the impact of COD on MFC performance did not use the actual wastewater. Moreover, they did not systematically explore the effect of wastewater concentration on microbial community structure, not to mention the influence mechanism of concentration variation on MFC [14]. Therefore, it is critical to investigate the influence of the concentration variation of swine wastewater on the performance of MFC, as well as the microbial community near anode.
In this study, parallel-operated double-chambered MFCs using actual swine wastewater as the substrate were constructed. Based on the field investigation, the concentrations of 800 mg/L, 1600 mg/L and 2500 mg/L were chosen to compare the effects on the performance of MFCs. The influence mechanism of concentration variation on the performance of the battery was analyzed from the perspective of the biological community. The predominant flora of MFC based on swine wastewater under the condition of variable concentration is preliminarily determined. The experimental results could provide guidance for livestock wastewater treatment and MFC performance enhancement. Moreover, the influence mechanism of substrate concentration variation on the production of microorganisms is exhibited.
2. Materials and Methods
2.1. Materials
As shown in Figure 1, four identical double-chambered MFC reactors (250 mL) were fabricated using transparent plexiglass, which were separated by the Nafion 117 proton exchange membranes (50 mm * 50 mm) from DuPont (DuPont China Holding Co., Ltd. Beijing Branch, Beijing, China). All carbon cloth anodes (Φ16 mm, HCP330N, Shanghai Hesen Electric Co., Ltd., Shanghai, China) were first soaked in acetone for 3 h and then rinsed with the ultrapure water to neutrality. Finally, they were dried under 60 °C for spare. The cathode employed the same carbon cloth material as anodes, with 0.35 mg/m2 Pt catalyst distributed on its surface. The two electrodes of MFC were connected by an external titanium conductor with resistance of 1000 Ω to form a closed-loop circuit.
The inoculation solution of anode chamber included anaerobic sludge, swine wastewater and inoculum. Inoculum was arranged as previously described. The solution in cathode chamber was comprised of 0.1 mol/L K3[Fe (CN)6] and 50 mM phosphate buffer [15]. Anaerobic sludge was initially collected from a sewage disposal factory in Nantong, China. After two weeks of anaerobic incubation, it was filled to the anode chamber in MFCs. Swine wastewater was obtained from the supernatant of a pig farm in Nantong before fermentation, and stored in the refrigerator with a temperature of 4 °C.
2.2. Construction and Operation
Each MFC reactor used in the experiment started in fed-batch mode based on 2500 mg/L of swine wastewater, and the anode solution was updated every 48 h. The experiment was divided into 3 phases. Phase 1: two reactors were filled with 800 mg/L (recorded as L) and 2500 mg/L (recorded as H) swine wastewater respectively for 2 cycles, while another two reactors were both filled with 1600 mg/L swine wastewater, which were recorded as M_H_L, and M_L_H, separately. Phase 2: The M_H_L and M_L_H were swapped with 2500 mg/L and 800 mg/L swine wastewater and ran for 2 cycles. The H and L continued to run without replacing the anolyte. Phase 3: the M_H_L and M_L_H were replaced with 800 mg/L and 2500 mg/L swine wastewater, respectively, and operated for another 2 cycles, as shown in Figure 2. All reactors were operated at a temperature of 30 °C. After two weeks of stable operation, the stable voltage profiles, polarization curves, COD removal rates and microbial diversity were measured three times, respectively.
2.3. Statistical Analysis
With the help of the upper computer of LabVIEW, the external voltage of MFC was measured and recorded online using a data acquisition board (NI USB-6343, National Instruments Co., Ltd., Guangdong, China). The detection frequency was 60 times/h. The polarization curve and power density curve were drawn by steady state discharge method [16]. The power density was calculated by the following formula:
(1)
where PAn is power density (MW/m2); U is operating voltage (mV); Rex is external circuit resistance (Ω); SAn is anode electrode surface area (m2).The sewage samples purified by MFC were filtered by 0.45 μm drainage membrane (Jingteng Experimental Equipment Co., Ltd., Tianjin, China). The COD concentrations were measured by water quality analyzer (DR3900, HACH, CO, USA) and the COD removal rates were calculated.
The PowerSoilTM DNA isolation Kit (MoBio, Carlsbad, CA, USA) was used to extract the DNA of MFC anode biofilm after two cycles of stable operations. The 16S universal primers 338F (5′-ACTCCTACGGGAGGCAGCA-3′) and 806R (5′-GGACTACHVGGGTWTCTAAT-3′) were used to amplify the V3~V4 regions of the 16S rDNA gene. Barcoded 16S rDNA gene polymerase chain reaction (PCR) amplicons were derived in sequence on the Illumina Miseq platform. The qualified sequences were clustered into operational taxonomic units (OTUs) with 97% similarity cutoff by the SRA (Sequence Read Archive,
3. Results
3.1. MFC Performance
3.1.1. Power Generation Performance
All reactors were started by using the swine wastewater with the same concentration. The mapping voltage variation curve is shown in Figure 3. In Phase 1, the voltage amplitude decrements varied greatly among reactors. Under steady state, the maximum voltage was H (0.61 V), followed by M_H_L, M_L_H and L, indicating that the voltage in Phase 1 was mainly affected by the concentration of wastewater, and they were positively correlated. In Phase 2, the voltage difference in M_H_L and M_L_H was larger than it was in Phase 1, which means the concentration variation of anolyte directly influences voltage recovery. Although the stable voltage in M_H_L was higher than M_L_H, they both were lower than that in Phase 1. The reason may be that microbial community structure affected by concentration could compromise the MFC performance. In Phase 3, both the voltage change rate and stable voltage in M_H_L and M_L_H decreased relatively, which indicated that the concentration variation may choose to cultivate a more adaptable dominant bacteria group. The stable voltage of MFC based on 2500 mg/L and 800 mg/L was lower than that in H and L. No matter how the concentration changed, the maximum stable voltage of MFC was suppressed. The maximum voltage duration in M_H_L and M_L_H was longer than that in L and H, indicating that the change of concentration was beneficial for the stable operation of MFC.
In order to analyze the influence of variable concentration of swine wastewater on the MFC performance, the polarization curves and power density curves were obtained after each replacement of different concentrations of swine wastewater in MFC (Figure 4). The maximum power density of H (770.97 MW/m2), M_H_L (616.11 MW/m2), M_L_H (503.44 MW/m2), and L (317.19 MW/m2) in Phase 1 (Figure 4a) was measured and ranked in turns, as well as the output voltage of MFC. In Phase 2 (Figure 4b), the maximum power density in M_H_L (585.18 MW/m2) was significantly higher than that in M_L_H (430.76 MW/m2), but both were lower than the previous phase. In Phase 3 (Figure 4c), the maximum power density in M_H_L (585.18 MW/m2) was apparently higher than that in M_L_H (430.76 MW/m2), and both were lower than the previous phase. Therefore, the power density of M_H_L or M_L_H had a positive correlation with the concentration of swine wastewater, which was consistent with the previous [18].
3.1.2. Decontamination Performance
The decontamination performance of MFC was evaluated by the COD removal rate (Table 1). Combined with the analysis of MFC electricity production, it was found that the microbial community structure was varied with different concentrations, and the dominant bacteria in a short period (4 days) can adapt to high concentration successfully. The COD removal rate of the final effluent of MFC was positively correlated with COD of swine wastewater in Phase 3. The dominant bacteria capable of effectively resolving pollutants may not survive well in variable concentration of swine wastewater. The microorganisms which were selectively cultured by variable concentrations in the anode chamber could increase the degradation rate of 2500 mg/L and 800 mg/L swine wastewater by 12.5% and 208%, respectively, which is different from the previous report. This result indicates that the substrate used in this experiment was actual swine wastewater with a relatively low concentration range.
3.2. Microbial Community Diversity
In order to analyze the mechanism of variable concentration on cell performance from the perspective of the biological community, the original sequences of raw sludge, 2500 mg/L swine wastewater (Swine) and four experimental groups were optimized by the Illumina sequencing analysis, leading to a total of 226,646 optimized sequences. The sequences were selected by nucleotide identification, where the similarity with operational taxonomic units (OTU) was more than 97%. The species richness and diversity of the environmental communities were analyzed by calculating the indexes of Chao, Heip, Shannon and Coverage (Table 2). Based on the Chao index, the L group was found as the group with the highest species richness, followed by the H, M_H_L, Sludge, M_L_H and Swine groups. The Heip index shows that the species evenness, in descending order, was Swine, Sludge, M_H_L, L, H, and M_L_H. The Shannon index indicates that the order of community diversity was L, Sludge, Swine, H, M_H_L and M_L_H. The values of coverage in Table 2 are converging to one, while all rarefaction curves in Figure 5 tend to be flat, showing that the sequencing data used in the microbial diversity analysis are sufficient to reflect the species diversity in the samples. The results demonstrate that the microbial community diversity is directly affected by the concentration, and the species richness of the biofilm selected by the MFC is higher than that of Sludge and Swine, although the diversity index is slightly lower. Moreover, the diversity index tends to be higher at lower concentrations, and the community diversity of the MFC anode can be reduced by variable concentration, which may improve the performance of electricity generation and pollutant removal [19].
3.3. Microbial Community Structure
The comparison of microbial communities in different samples at phylum level is useful to analyze the function of some special species in MFC. As shown in Table 3, the bacteria are mainly distributed in Proteobacteria (60.45%), Bacteroidetes (18.72%), Firmicutes (4.75%), Chloroflexi (4.73%) and Spirochaetae (4.54%). Proteobacteria and Bacteroidetes are dominant groups in each sample. The relative abundance of Proteobacteria in Sludge or Swine is significantly less than that in the experimental groups, indicating that Proteobacteria are beneficial to improve the MFC performance. The relative abundance of Proteobacteria in the M_H_L or M_L_H groups are higher than that in H or L, showing that Proteobacteria could adapt well to a changing environment, especially one with a variable concentration, which is consistent with previous reports [20]. Compared with the experimental groups, Bacteroidetes occupy a greater proportion in Sludge and Swine, and the highest proportion in H, indicating that Bacteroidetes can effectively improve the electricity generation performance while maintaining the stable operation of MFC. Mei et al. constructed a single-chamber air cathode MFC based on waste water, and found that the Bacteroidetes of anode dominant bacteria could adapt to the changing external micro-ecological environment and improve the performance of MFC [21]. Firmicutes account for 44.56% in Swine, and belong to the dominant groups in M_H_L and M_L_H, which was reported in many dominant electricigens [22]. This finding indicates that Firmicutes in the experimental groups were mainly introduced from the wastewater, and the performance of Firmicutes adapted to variable concentration environment was better than its electricity generation performance. In the experimental groups, Chloroflexi were mainly introduced from the sludge but in a small proportion, indicating that they could not adapt to the variable concentration environment of swine wastewater, which complies with the previous conclusion. At the same time, the relative abundance of Spirochaetes in the experimental groups was lower than that in Sludge and Swine, indicating that the enrichment of Spirochaetes is beneficial to maintain the stable operation of MFC under the variable concentration environment conditions [23,24].
According to Table 3, the dominant bacteria in the MFC anode chamber were mostly obtained from the sludge, but the original dominant bacteria in the swine wastewater, such as Firmicutes, were more useful to maintain the stable operation of the MFC. Variable concentration environments would selectively culture the initial flora, whose species structure is significantly different from that under the constant concentration environment. In the initial flora, Firmicutes and Spirochaetae can enhance the electricity production of MFC and show better adaption to the variable concentration environment, while the adaptability of Actinobacteria, Chloroflexi, Proteobacteria and Synergistetes is relatively poorer.
As shown in Figure 6, the experimental results are different between the groups of Sludge and Swine at the genus level. The community composition of M_H_L is closer to that of M_L_H, while the compositions of H and L are closer to each other, indicating that environmental conditions directly affect the community structure of the anode surface. As shown in Figure 7, the relative abundance that exceeds 1% at the genus level of each sample are Zoogloea (5.79%), Plasticicumulans (4.59%), Bacteroidetes_unclassified (3.55%), Comamonadaceae unclassified (2.81%), Azoarcus (2.71%), Comamonas (2.48%) and Methylomonas (2.43%). Zoogloea was proven to be able to adapt to the temperature change effectively while producing electricity steadily [25]. Tamis et al. found that the accumulation of Plasticicumulans was beneficial to the degradation of acetic acid and other small molecular fatty acids. Moreover, he also proved that the dominant bacteria were not necessarily capable of producing electricity, but they could degrade organic compounds or provide excellent prerequisite substances for the exoelectrogens to assist electricity generation. Azoarcus [26] and Comamonas [27] were the reported bacteria that can degrade sewage effectively, while a small amount of Methylomonas can oxidize methane into carbon dioxide and assist in the production of electricity [28]. The production performance of other unclassified bacteria remains to be further proved.
4. Conclusions
The concentration of wastewater in the anode chamber directly affects the power generation and decontamination performance of the MFC. The concentration of COD is positively correlated with the output voltage and the removal rate of COD. The abrupt change of concentration suppresses the ability of MFC voltage recovery and decontamination. The dominant bacteria in the anode chamber have a stronger environmental adaptability under lower concentrations. Variable concentration environments can reduce microbial diversity to decrease the electricity production of MFC, but the selectively cultured bacteria with a better adaptation capability could enhance the stability and decontamination performance of the MFC. The dominant bacteria in the experimental groups were mainly distributed in Proteobacteria, Bacteroidetes, Firmicutes, Chloroflexi and Spirochaetae, while Zoogloea and Plasticicumulans might be the most important bacteria to enhance the performance of the MFC.
5. Patents
The authors of this paper have carried out research on the microbial fuel cell for many years. Four China invention patents related to this paper have been granted; the patent numbers are CN106784952B, CN106876760B, CN106848361B and CN108075162B. In addition, four China invention patents have been published; the patent numbers are CN110713899A, CN110669644A, CN108101211A and CN108996699A.
Author Contributions
Conceptualization, H.N.; Data curation, X.W. and J.Z.; Formal analysis, H.N., K.W. and L.Z.; Funding acquisition, S.L.; Investigation, S.L.; Methodology, K.W. and S.L.; Resources, H.N.; Software, K.W. and L.Z.; Supervision, H.N.; Validation, X.W.; Visualization, J.Z.; Writing—original draft, K.W.; Writing—review & editing, H.N. All authors have read and agreed to the published version of the manuscript.
Funding
This research was funded by the Priority Academic Program Development of Jiangsu Higher Education Institutions, grant number PAPD; Nantong Applied Research Project, grant number JC2018115 and JC2019129; Ministry of education’s Cooperative Education Project, grant number 201901189019.
Conflicts of Interest
The authors declare no conflict of interest.
Figures and Tables
Figure 1. The diagram of the microbial fuel cell (MFC): (a) single microbial fuel cell; (b) microbial fuel cell stacks.
Figure 3. Stable voltage profiles of MFCs along with substrate concentration variation.
Figure 4. Polarization curves and power density curves of MFC at different phases:(a) polarization curves and power density curves of M_H_L, M_L_H, H and L in Phase 1; (b) polarization curves and power density curves of M_H_L and M_L_H in Phase 2; (c) polarization curves and power density curves of M_H_L and M_L_H in Phase 3.
Figure 5. Rarefaction curves of operational taxonomic unit (OTU) richness of the anode biofilms in M_H_L, M_L_H, H, L, Sludge and Swine.
Figure 6. Hierarchical clustering tree on genus level in M_H_L, M_L_H, H, L, Sludge and Swine.
Figure 7. Relative ratio of the dominant microbial at genus level in M_H_L, M_L_H, H, L, Sludge and Swine.
Chemical oxygen demand (COD) removal rate of swine wastewater.
| Group | Influent COD (mg/L) | COD Removal Rate in Phase 1 (%) | COD Removal Rate in Phase 2 (%) | COD Removal Rate in Phase 3 (%) | COD Removal Rate of Effluent (%) |
|---|---|---|---|---|---|
| M_H_L | 1600 | 60.56 | 45.2 | 14 | 42.38 |
| M_L_H | 1600 | 66.56 | 27.25 | 63.08 | 72.4 |
| H | 2500 | - | - | - | 64.36 |
| L | 800 | - | - | - | 13.75 |
Alpha diversity analysis.
| Sample | Seqs | OTU | Chao | Heip | Shannon | Coverage |
|---|---|---|---|---|---|---|
| M_H_L | 35,458 | 594 | 695 (658,754) | 0.2124 | 4.84 (4.82,4.86) | 0.9942 |
| M_L_H | 33,177 | 569 | 627 (604,667) | 0.1915 | 4.69 (4.66,4.71) | 0.9952 |
| H | 35,632 | 664 | 783 (739,853) | 0.1920 | 4.85 (4.83,4.87) | 0.9955 |
| L | 35,340 | 692 | 798 (758,862) | 0.2118 | 4.99 (4.97,5.02) | 0.9951 |
| Sludge | 42,403 | 599 | 674 (641,732) | 0.2331 | 4.94 (4.92,4.96) | 0.9971 |
| Swine | 44,636 | 464 | 488 (475,514) | 0.2829 | 4.87 (4.85,4.88) | 0.9981 |
Comparison of relative abundance of anode microbial community in M_H_L, M_L_H, H, L, Sludge and Swine at phylum level.
| Phylum | Abundance (Above 0.1%) | SEM | p-Value | |||||
|---|---|---|---|---|---|---|---|---|
| Sludge | Swine | M_H_L | M_L_H | H | L | |||
| Acidobacteria | 6.69% | 0.02% | 0.74% | 0.40% | 1.02% | 2.78% | 1.03% | 0.07 |
| Actinobacteria | 2.32% | 0.83% | 1.92% | 2.31% | 2.17% | 2.23% | 0.23% | 0.02 |
| Bacteroidetes | 17.35% | 32.25% | 15.96% | 15.89% | 25.63% | 15.59% | 2.83% | 0.17 |
| Chloroflexi | 23.62% | 0.00% | 2.43% | 1.50% | 4.54% | 9.65% | 3.60% | 0.24 |
| Cyanobacteria | 1.31% | 0.01% | 0.17% | 0.92% | 0.23% | 0.67% | 0.21% | 0.01 |
| Firmicutes | 0.97% | 44.56% | 7.81% | 4.44% | 3.43% | 3.83% | 6.80% | 0.01 |
| Gemmatimonadetes | 1.81% | 0.00% | 0.11% | 0.01% | 0.07% | 0.13% | 0.29% | 0.02 |
| Ignavibacteriae | 1.43% | 0.00% | 0.13% | 0.03% | 0.15% | 0.33% | 0.22% | 0.01 |
| Nitrospirae | 1.26% | 0.00% | 0.02% | 0.01% | 0.16% | 0.31% | 0.19% | 0.01 |
| Parcubacteria | 4.82% | 0.02% | 0.00% | 0.01% | 0.00% | 0.00% | 0.80% | 0.05 |
| Proteobacteria | 33.17% | 19.91% | 66.07% | 66.55% | 53.14% | 58.81% | 7.76% | 0.33 |
| Saccharibacteria | 1.36% | 0.04% | 0.34% | 0.66% | 0.15% | 0.34% | 0.19% | 0.01 |
| Spirochaetae | 0.33% | 0.73% | 3.54% | 5.86% | 6.11% | 2.53% | 1.04% | <0.01 |
| Synergistetes | 0.05% | 0.06% | 0.29% | 0.64% | 1.35% | 0.55% | 0.20% | <0.01 |
| Verrucomicrobia | 0.05% | 0.14% | 0.03% | 0.42% | 0.51% | 1.31% | 0.20% | <0.01 |
| others | 3.46% | 1.43% | 0.44% | 0.35% | 1.34% | 0.94% | 0.46% | 0.03 |
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
© 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.
Abstract
The variation of substrate concentration in anode chamber directly affects the power generation efficiency and decontamination performance of microbial fuel cell (MFC). In this study, three concentrations of swine wastewater with 800 mg/L, 1600 mg/L and 2500 mg/L were selected as substrates, and the performance of MFC and response characteristics of anode microbial community were investigated. The results show that the concentration of a selected substrate is positively correlated with the output voltage of MFC and chemical oxygen demand (COD) removal rate. The microbial community diversity in the anode chamber and the performance of battery can be significantly affected when concentration changes in different ways, which helps to selectively cultivate the adaptable dominant bacteria to enhance the stability and decontamination performance of MFC. The community structure of anodic biofilm is mainly composed of Proteobacteria, Bacteroidetes, Firmicutes, Chloroflexi and Spirochaetae. These findings are meaningful to improve the treatment effects of swine wastewater and can help to find out the mechanism of varying concentration that influences the production of microorganisms in MFC.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Details
1 School of Mechanical Engineering, Nantong University, Nantong 226019, China;
2 School of Mechanical Engineering, Nantong University, Nantong 226019, China;




