© 2020 Horehledova et al. This is an open access article distributed under the terms of the Creative Commons Attribution License: http://creativecommons.org/licenses/by/4.0/ (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Background

Multidetector computed tomography (MDCT) plays a key role in patient assessment prior to transcatheter aortic valve implantation (TAVI). However, to date no consensus has been established on what is the optimal pre-procedural imaging protocol. Variability in pre-TAVI acquisition protocols may lead to discrepancies in aortic annulus measurements and may potentially influence prosthesis size selection.

Purpose

The current study evaluates the magnitude of differences in aortic annulus measurements using max-systolic, end-diastolic, and non-ECG-synchronized imaging, as well as the impact of method on prosthesis size selection.

Material and methods

Fifty consecutive TAVI-candidates, who underwent retrospectively-ECG-gated CT angiography (CTA) of the aortic root, directly followed by non-ECG-synchronized high-pitch CT of the entire aorta, were retrospectively included. Aortic root dimensions were assessed at each 10% increment of the R-R interval (0–100%) and on the non-ECG-synchronized scan. Dimensional changes within the cardiac cycle were evaluated using a 1-way repeated ANOVA. Agreement in measurements between max-systole, end-diastole and non-ECG-synchronized scans was assessed with Bland-Altman analysis.

Results

Maximal dimensions of the aortic root structures and minimum annulus-coronary ostia distances were measured during systole. Max-systolic measurements were significantly and substantially larger than end-diastolic (p<0.001) and non-ECG-synchronized measurements (p<0.001). Due to these discrepancies, the three methods resulted in the same prosthesis size selection in only 48–62% of patients.

Conclusions

The systematic differences between max-systolic, end-diastolic and non-ECG-synchronized measurements for relevant aortic annular dimensions are both statistically significant and clinically relevant. Imaging strategy impacts prosthesis size selection in nearly half the TAVI-candidates. End-diastolic and non-ECG-synchronized imaging does not provide optimal information for prosthesis size selection. Systolic image acquisition is necessary for assessment of maximal annular dimensions and minimum annulus-coronary ostia distances.

Details

Title
Retrospectively ECG-gated helical vs. non-ECG-synchronized high-pitch CTA of the aortic root for TAVI planning
Author
Horehledova, Barbora; Casper Mihl; Boswijk, Ellen; Genevieve A J C Crombag; Nijssen, Estelle C; Nelemans, Patty J; Veenstra, Leo F; Wildberger, Joachim E; Das, Marco
First page
e0232673
Section
Research Article
Publication year
2020
Publication date
May 2020
Publisher
Public Library of Science
e-ISSN
19326203
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2401744030
Copyright
© 2020 Horehledova et al. This is an open access article distributed under the terms of the Creative Commons Attribution License: http://creativecommons.org/licenses/by/4.0/ (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.