Abstract
Background
Mechanical ventilation (MV), compared to spontaneous breathing (SB), has been found to increase abdominal edema and inflammation in experimental sepsis. Our hypothesis was that in primary acute respiratory distress syndrome (ARDS) MV would enhance inflammation and edema in the abdomen.
Methods
Thirteen piglets were randomized into two groups (SB and MV) after the induction of ARDS by lung lavage and 1 h of injurious ventilation.
1. SB: continuous positive airway pressure 15 cmH2O, fraction of inspired oxygen (FIO2) 0.5 and respiratory rate (RR) maintained at about 40 cycles min− 1 by titrating remifentanil infusion.
2. MV: volume control, tidal volume 6 ml kg− 1, positive end-expiratory pressure 15 cmH2O, RR 40 cycles min− 1, FIO2 0.5.
Main outcomes: abdominal edema, assessed by tissues histopathology and wet-dry weight; abdominal inflammation, assessed by cytokine concentration in tissues, blood and ascites, and tissue histopathology.
Results
The groups did not show significant differences in hemodynamic or respiratory parameters. Moreover, edema and inflammation in the abdominal organs were similar. However, blood IL6 increased in the MV group in all vascular beds (p < 0.001). In addition, TNFα ratio in blood increased through the lungs in MV group (+ 26% ± 3) but decreased in the SB group (− 17% ± 3).
Conclusions
There were no differences between the MV and SB group for abdominal edema or inflammation. However, the systemic increase in IL6 and the TNFα increase through the lungs suggest that MV, in this model, was harmful to the lungs.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer