© 2020 Krammel et al. This is an open access article distributed under the terms of the Creative Commons Attribution License: http://creativecommons.org/licenses/by/4.0/ (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Background

Laypersons’ efforts to initiate basic life support (BLS) in witnessed Out-of-Hospital Cardiac Arrest (OHCA) remain comparably low within western society. Therefore, in order to shorten no-flow times in cardiac arrest, several police-based first responder systems equipped with automated external defibrillators (Pol-AED) were established in urban areas, which subsequently allow early BLS and AED administration by police officers. However, data on the quality of BLS and AED use in such a system and its impact on patient outcome remain scarce and inconclusive.

Methods

A total of 85 Pol-AED cases were randomly assigned to a gender, age and first rhythm matched non-Pol-AED control group (n = 170) in a 1:2 ratio. Data on quality of BLS were extracted via trans-thoracic impedance tracings of used AED devices.

Results

Comparing Pol-AED cases and the control group, we observed a similar compression rate per minute (p = 0.677) and compression ratio (p = 0.651), mirroring an overall high quality of BLS administered by police officers. Time to the first shock was significantly shorter in Pol-AED cases (6 minutes [IQR: 2–10] vs. 12 minutes [IQR: 8–17]; p<0.001). While Pol-AED was not associated with increased sustained return of spontaneous circulation (p = 0.564), a strong and independent impact on survival until hospital discharge (adj. OR: 1.85 [95%CI: 1.06–3.23; p = 0.030]) and a borderline significance for the association with favorable neurological outcome (adj. OR: 1.58 [95%CI: 0.96–2.89; p = 0.052) were observed.

Conclusion

We were able to demonstrate an early start and a high quality of BLS and AED use in Pol-AED assessed OHCA cases. Moreover, the presence of Pol-AED care was associated with better patient survival and borderline significance for favorable neurological outcome.

Details

Title
The impact of a high-quality basic life support police-based first responder system on outcome after out-of-hospital cardiac arrest
Author
Krammel, Mario; Lobmeyr, Elisabeth; Sulzgruber, Patrick; Winnisch, Markus; Weidenauer, David; Poppe, Michael; Datler, Philip; Zeiner, Sebastian; Keferboeck, Markus; Eichelter, Jakob; Hamp, Thomas; Uray, Thomas; Schnaubelt, Sebastian; Nuernberger, Alexander
First page
e0233966
Section
Research Article
Publication year
2020
Publication date
Jun 2020
Publisher
Public Library of Science
e-ISSN
19326203
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2408809544
Copyright
© 2020 Krammel et al. This is an open access article distributed under the terms of the Creative Commons Attribution License: http://creativecommons.org/licenses/by/4.0/ (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.