It appears you don't have support to open PDFs in this web browser. To view this file, Open with your PDF reader
Abstract
Background
Point-of-care ultrasound (PoCUS) by emergency physicians for renal colic has been proposed as an alternative to computed tomography (CT) to avoid ionizing radiation exposure and shorten emergency department length of stay. Previous studies have employed experienced or credentialed ultrasonographers or required advanced ultrasound skills. We sought to measure the diagnostic accuracy of PoCUS by physicians with varied experience using a simplified binary outcome of presence or absence of hydronephrosis. Secondary outcomes include assessment as to whether the presence of hydronephrosis on PoCUS is predictive of complications, and to evaluate possible causes for the reduced diagnostic accuracy such as body mass index (BMI) and time between PoCUS and formal imaging, and scanner experience.
Results
413 patients were enrolled in the study. PoCUS showed a specificity of 71.8% [95% CI 65.0, 77.9] and sensitivity of 77.1% [95% CI 70.9, 82.6]. Hydronephrosis on PoCUS was predictive of complications (relative risk 3.13; [95% CI 1.30, 7.53]). The time interval between PoCUS and formal imaging, BMI, and scanner experience did not influence the accuracy of PoCUS.
Conclusions
PoCUS for hydronephrosis in suspected renal colic has moderate accuracy when performed by providers with varied experience for the binary outcome of presence or absence of hydronephrosis. Hydronephrosis on PoCUS is associated with increased rates of complications. PoCUS for hydronephrosis is limited in its utility as a stand-alone test, however this inexpensive, readily available test may be useful in conjunction with clinical course to determine which patients would benefit from formal imaging or urologic consultation.
ClinicalTrials.gov Identifier NCT01323842
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Details

1 Queen’s University, Department of Emergency Medicine, Kingston, Canada (GRID:grid.410356.5) (ISNI:0000 0004 1936 8331)
2 Queen’s University, School of Medicine, Faculty of Health Sciences, Kingston, Canada (GRID:grid.410356.5) (ISNI:0000 0004 1936 8331)
3 Queen’s University, Department of Radiology, Kingston, Canada (GRID:grid.410356.5) (ISNI:0000 0004 1936 8331)