Introduction
The seismic stations described in this manuscript
are part of the international AlpArray temporary seismic network
(
Here we describe the site selection criteria, technical realization and noise performance of thirty temporary seismic broadband stations operated by the Department of Meteorology and Geophysics, University of Vienna in the context of AlpArray in eastern Austria and western Slovakia (see Table for a complete station list). Few of the stations were already described in more detail by .
List of AlpArray stations described in this manuscript.
Network | Station | Latitude | Longitude | Elevation (m) | Site Name | Country | Housing type | Sensor ground | Sensor | Datalogger | Power | GPS |
---|---|---|---|---|---|---|---|---|---|---|---|---|
Z3 | A001A | 48.7287 | 16.5904 | 337 | Falkenstein | Austria | Underground shelter | concrete | Reftek 151A 60s | Reftek 130S | 2 100 W solar | outdoor |
Z3 | A002A | 48.3175 | 16.6152 | 162 | Strasshof | Austria | Building | concrete | Reftek 151A 60s | Reftek 130 | grid | outdoor |
Z3 | A002B | 48.3629 | 16.5942 | 187 | Bockfließ | Austria | Underground shelter | concrete in soil | Reftek 151A 60s | Reftek 130 | grid | outdoor |
Z3 | A003A | 47.7589 | 17.0530 | 116 | Andau | Austria | Building | concrete | Reftek 151A 60s | Reftek 130 | grid | window |
Z3 | A004A | 47.9629 | 16.3968 | 200 | Ebreichsdorf | Austria | Castle | concrete | Reftek 151A 60s | Reftek 130 | grid | outdoor |
Z3 | A005A | 48.3784 | 16.1207 | 176 | Schmida | Austria | Urban free field | concrete | Reftek 151A 60s | Reftek 130 | grid | outdoor |
Z3 | A005B | 48.3719 | 16.2054 | 174 | Stockerau | Austria | Underground shelter | hard soil | Reftek 151A 60s | Reftek 130 | grid | outdoor |
Z3 | A006A | 48.7404 | 16.0203 | 230 | Kleinriedenthal | Austria | Underground shelter | concrete in soil | Reftek 151A 60s | Reftek 130 | grid | roof |
Z3 | A007A | 48.7162 | 15.5288 | 484 | Messern | Austria | Castle | concrete on bedrock | Reftek 151A 60s | Reftek 130S | grid | outdoor |
Z3 | A008A | 48.3687 | 15.6522 | 242 | Tiefenfucha | Austria | Urban free field | concrete on soil | Reftek 151A 60s | Reftek 130 | grid | roof |
Z3 | A009A | 47.6775 | 16.0904 | 469 | Wartmannstetten | Austria | Underground shelter | concrete | Reftek 151A 60s | Reftek 130 | grid | outdoor |
Z3 | A010A | 47.0733 | 16.0793 | 266 | Fürstenfeld | Austria | Building | concrete | Reftek 151A 60s | Reftek 130 | 2 100 W solar | window |
Z3 | A011A | 47.3908 | 16.0077 | 507 | Rohrbach a.d. Lafnitz | Austria | Urban free field | concrete | Reftek 151B 60s | Reftek 130S | 2 100 W solar | roof |
Z3 | A011B | 47.4086 | 15.9587 | 556 | Reinberg | Austria | Building | stone patches in cement | Reftek 151B 60s | Reftek 130S | grid | window |
Z3 | A012A | 47.6040 | 15.5860 | 1280 | Langenwang | Austria | Urban free field | concrete | Reftek 151B 60s | Reftek 130S | 100 W solar + fuel cell | roof |
Z3 | A013A | 48.0635 | 15.4063 | 530 | Umbach | Austria | Building | concrete | Reftek 151B 60s | Reftek 130S | grid | outdoor |
Z3 | A014A | 48.3483 | 15.1619 | 773 | Thumling | Austria | Building | concrete in soil | Reftek 151B 60s | Reftek 130 | grid | outdoor |
Z3 | A016A | 48.3014 | 14.6496 | 565 | Allerheiligen | Austria | Building | tiles | Reftek 151B 60s | Reftek 130S | grid | window |
Z3 | A017A | 47.9480 | 14.7589 | 589 | Waidhofen a.d. Ybbs | Austria | Urban free field | concrete | Reftek 151B 60s | Reftek 130S | 100 W solar + fuel cell | outdoor |
Z3 | A018A | 47.7437 | 15.0776 | 748 | Rothwald | Austria | Building | concrete | Reftek 151B 60s | Reftek 130S | grid | roof |
Z3 | A019A | 47.4457 | 15.0856 | 1125 | Kaintal | Austria | Urban free field | concrete | Reftek 151B 60s | Reftek 130S | 2 100 W solar | roof |
Z3 | A020A | 46.9484 | 15.2994 | 390 | Lannach | Austria | Building | concrete | Reftek 151A 60s | Reftek 130 | grid | window |
Z3 | A021A | 46.7566 | 15.8253 | 265 | Deutsch Goritz | Austria | Urban free field | concrete | Reftek 151A 60s | Reftek 130 | grid | window |
Z3 | A024A | 48.2131 | 14.1367 | 303 | Marchtrenk | Austria | Building | concrete | Reftek 151B 60s | Reftek 130S | grid | outdoor |
Z3 | A024B | 48.1002 | 14.1398 | 381 | Sipbachzell | Austria | Building | concrete | Reftek 151B 60s | Reftek 130S | grid | indoor |
Z3 | A331A | 49.1501 | 18.2209 | 427 | Zubak | Slovakia | Building | concrete | Reftek 151A 60s | Reftek 130S | grid | window |
Z3 | A332A | 48.8045 | 18.4645 | 359 | Rudnianska lehota | Slovakia | Building | tiles | Reftek 151A 60s | Reftek 130S | grid | window |
Z3 | A333A | 48.7156 | 17.1041 | 177 | Gbely | Slovakia | Building | tiles | Reftek 151A 60s | Reftek 130 | grid | window |
Z3 | A334A | 48.6044 | 17.6747 | 224 | Sterusy | Slovakia | Urban free field | tiles | Reftek 151A 60s | Reftek 130 | grid | window |
Z3 | A335A | 48.4469 | 18.3359 | 320 | Lovce | Slovakia | Building | concrete | Reftek 151B 60s | Reftek 130S | grid | outdoor |
Z3 | A336A | 48.2333 | 18.9990 | 183 | Medovarce | Slovakia | Cave | bedrock | Reftek 151B 60s | Reftek 130S | grid | outdoor |
Z3 | A337A | 48.2443 | 17.7898 | 117 | Vahovce | Slovakia | Building | concrete | Reftek 151B 60s | Reftek 130 | grid | outdoor |
Z3 | A338A | 48.0152 | 18.3525 | 154 | Semerovo | Slovakia | Building | concrete | Reftek 151B 60s | Reftek 130S | grid | window |
Z3 | A339A | 47.8294 | 17.6559 | 110 | Balon | Slovakia | Building | tiles | Reftek 151B 60s | Reftek 130S | grid | roof |
Map of seismic stations described in this manuscript. The inset outlines the mapped area. Red dots denote the 30 temporary AlpArray stations owned and operated by the Department of Meteorology and Geophysics, University of Vienna. White dots represent temporary AlpArray stations operated by other institutions. Black triangles mark the permanent seismic stations maintained by the earthquake observatories in Austria, Slovakia, Czech Republic and Hungary, respectively. The numbers inside the red dots abbreviate the station name in the following pattern: Austria stations A0xxA, Slovakia stations A3xxA.
[Figure omitted. See PDF]
Network layout, site selection and station design
Network layout
The AlpArray temporary seismic network is designed to complement existing permanent seismic stations in the greater Alpine area in Europe. In Austria, the Austrian Central Institute for Meteorology and Geodynamics (ZAMG) currently operates 17 permanent broadband stations which contribute data to the AlpArray seismic network. In Slovakia, the Earth Science Institute at the Slovak Academy of Sciences operates 4 permanent seismic broadband stations within the bounds of the AlpArray network. The temporary broadband seismic stations installed in the context of AlpArray densify the permanent networks to achieve a uniform coverage with approximately 40 km inter-station spacing (see Fig. ) over the greater Alpine area. Theoretical coordinates for all temporary AlpArray stations were computed by the AlpArray seismic network managers to obtain homogeneous coverage throughout the entire array and all stations must be installed within a 3 km radius (maximally 6 km if otherwise impossible) around these coordinates. This constraint strongly limits the choice of potential installation sites. The prospected duration of our temporary AlpArray installations is 2–3 years.
Site selection
During site selection for our temporary deployments we focused on the following aspects, taking into account both the quality of the seismic data as well as the ease of installation, reflecting the available project budget.
Accessibility and safety
All sites should be accessible by car and safe in terms of theft or flood risk and all parts of the station shall not be exposed to any risk of potential damage. Additionally, the terms and conditions of the instrument insurance require the seismic stations to be indoors in spaces that can be locked. The surroundings of the site should not significantly change over the course of three years (e.g. no ongoing or planned contruction).
Power supply
Most parts of Austria experience snow fall during winter and thus for many sites power supply through solar panels cannot be guaranteed. Hence, we prefer sites where power supply from the regular 50 Hz/230 V power grid is possible.
Connectivity
For monitoring purposes and to provide real-time waveform data in case of hazardous earthquakes, all seismic stations should send real-time data using the mobile network. Minimum requirement is sufficient signal strength and stability to transmit state-of-health data, while preferably continuous 100 sps waveform streams should be transmitted. For our instrumentation and 100 sps waveform data in STEIM1 compression format, the amount of data to transmit is approximately 30 Megabytes day for seismically quiet sites and 50 Megabytes day for noisy sites. Thus, for 100 sps real-time waveform streams a mobile bandwidth of 5–10 kbits s should be sufficient, which can even be achieved in GSM networks. In fact, stability of the mobile connection is more important than bandwidth.
Seismic noise
The AlpArray Working Group set the following requirements for temporary AlpArray stations: Average noise levels should be 20 dB lower than the New High Noise Model (NHNM) on all components within the 1–10 Hz frequency range. For long periods (30–200 s range) average noise levels on the vertical component should be 20 dB lower than the NHNM while on horizontal components noise levels should only be 10 dB less than the NHNM. This accounts for the strong sensitivity of horizontal components to e.g. long-period surface tilt from atmospheric pressure fluctuations. This reflects the fact that for near-surface stations, noise on horizontal components is usually stronger than on the vertical. Avoiding long-period noise on horizontal components requires advanced site preparation which is usually beyond the scope of temporary deployments.
Station design
Following the site requirements listed above, typical installation sites for our broadband instruments are basements in abandoned or occasionally used houses and huts. In various regions throughout Austria and Slovakia wine cellars and occasionally castles or bunkers could be found for seismic installations. We placed all sensors directly on solid ground – preferably flat bedrock, but more commonly concrete floors or tiles. If no such ground was available, we built a concrete base approximately 15–20 cm thick and cm wide (see Fig. a). The sensors are covered with textile bags fabricated from microfleece material with primaloft insulation and styrofoam boxes for thermal insulation (see Fig. b and c). To minimize air circulation we glue the bottom of the styrofoam boxes to the ground with silicon.
(a) Example of a concrete base if no solid ground is available (A006A). (b) and (c) Two-layer thermal insulation comprising a microfleece bag inside a styrofoam box. The box is glued to the ground with silicon. (b) Reftek 151 Type A sensor with connector at the bottom. (c) Reftek 151 Type B sensor with connector at the top.
[Figure omitted. See PDF]
A seismic station comprises the following components: a broadband sensor Reftek 151 “Observer” with 60 s effective eigenperiod together with a Reftek 130 or Reftek 130S 24 bit digitizer with 136 dB dynamic range (at 100 sps sampling rate), a continuous-mode Garmin/Reftek 130 GPS, a Digi WAN 3G mobile router for telemetry and up to two 100 Ah batteries. Figure shows the seismic equipment and Fig. shows a typical installation. Data is both stored locally (on two 8 or 16 GB flash cards) and (if possible) streamed in real-time.
Currently, 24 of 30 stations are powered through the electrical grid, four stations are powered by two 100 W solar panels (see Fig. a) and two stations are powered by one 100 W panel and one Efoy Pro 800 Duo fuel cell. The fuel cell acts as backup power source when the batteries are drained below a given threshold, which is mostly due to insufficient illumination of the solar panel during the winter season. Solar charge controllers protect the batteries from overcharging and disconnect any load from the batteries if they are drained below 11.5 V to protect them from deep draining. If installed, the fuel cells are configured such that they start charging the batteries once the voltage drops below 12 V.
Equipment used for the installations described in this manuscript. (a) Reftek 151 60s sensor, ( Reftek 130/130S digitizer, (c) Reftek 130 GPS antenna, (d) Textile thermal insulation cover for the sensor, (e) Mobile network antenna.
[Figure omitted. See PDF]
The antennas for GPS timing and cellular communication were in part mounted outdoors and in part (14 of 30 stations) indoors close to windows or under wooden roofs (see Fig. b and c). Regarding the GPS indoor antenna installations we were woried about signal loss in case of snow, but studies on regular GPS receivers buried by snow covers document high quality GPS reception even for snow heights up to one meter . Hence, for ease of installation and security we decided for the indoor installations in some cases. After approximately one year of data acquisition we cannot identify clear differences in the quality of the GPS signal between indoor and outdoor installations.
(a) Acquisition box containing the data logger Reftek 130/130S, the cellular router, the solar chargers and two 100 Ah batteries (not visible). (b) Typical setup of a seismic station as described in this manuscript (A017A).
[Figure omitted. See PDF]
(a) Example of solar panel mounting (A019A). If required, two 100 W solar panels are mounted, usually vertically on walls or chimneys. (b) GPS and GSM antenna mounted indoors below wooden roof (A018A). (c) GPS and GSM antenna mounted indoors close to window (A331A).
[Figure omitted. See PDF]
Sensor orientation
During the deployment, the sensor orientation along the (supposedly
geometrical) North–South axis was determined with a magnetic compass, not
accounting for the magnetic declination. If possible, the heading of the
magnetic compass was compared inside and outside of the housing structure
(e.g. by comparing the measured orientation of walls) and manually corrected
in case of strong differences. However, after the installation of all thirty
stations we re-measured and checked the orientation of all sensors with a
fiberoptic gyrocompass and discovered substantial deviations from true
geometrical North for approximately one third (11 of 30) of the sensors. For
those sensors, the Azimuth of the North-South component deviates more than 7 from geometrical North. Following the SEED and AlpArray guidelines,
for mis-oriented sensors we re-named the N and E channels to 2 and 3,
respectively, to make data users aware of the mis-orientation. The correct
sensor alignment for all stations is provided in the station metadata in
datalessSEED format. Apart from metadata access through e.g. EIDA, the latest
metadata of the 30 stations operated by University of Vienna is available at
Data transmission and completeness
All stations transmit 100 sps waveform streams and state of health data in real-time over the cellular network. Each station is equipped with a DIGI connect WAN 3G cellular router that automatically updates its current IP address via a dynamic DNS service to obtain a permanent domain name. Every five minutes our data retrieval server checks for and if necessary re-establishes a VPN connection with the cellular routers based on this dynamic DNS adress. This way the telemetry is not affected by changing mobile IP addresses in case of connection losses. Since in our setup the telemetry server is initiating the VPN connections with the mobile routers (because of very restrictive department firewall settings), all devices must be registered with public IP adresses, which is no longer common for mobile internet devices. Consequently, we registered all SIM cards for public IP addresses at the respective providers (A1 in Austria and Orange in Slovakia).
Completeness plot of 100 sps waveform data retrieved over telemetry. Small crosses mark start and end of the respective daily files and red lines/bars indicate data gaps. Data is from January to June 2016. The overall completeness is around 98 %.
[Figure omitted. See PDF]
For data transmission we use the Reftek proprietary RTPD protocol which allows for real-time waveform and state of health monitoring. Real-time data is forwarded to the Austrian earthquake observatory (ZAMG) from where it is streamed to the Orfeus Data Center (ODC) for archiving and distribution through EIDA.
As stated above, even 5–10 kbit s of mobile bandwidth are sufficient for
streaming 100 sps waveform data and hence we managed to have all 30 stations
send 100 sps streams in real-time. Still, in some remote areas we
occasionally experience loss of mobile signal and consequently a breakdown of
telemetry. In case of a connection loss, our Reftek digitizers are configured
such that they can keep recorded data in memory for up to 90 min before
it is discarded and not streamed over telemetry. All data is stored locally
on 16 or 32 GB flash cards in any case. Figure visualizes
the completeness of the 100 sps waveform data streamed from our stations
since January 2016. Averaged over all stations, between January and mid June
2016 we retrieved 98.6 % of the data in real-time. Throughout the operation
of our AlpArray stations, updated quarterly data completeness plots will be
made available at
Site descriptions
Our first temporary AlpArray station was installed in February 2015 (A009A) and we concluded the deployment in November 2015 (A010A). Few stations experienced power losses during the first winter months of 2015 because of insufficient solar power, but this was fixed (by adding a second solar panel or a fuel cell) before christmas 2015. Since January 2016 – which is the official AlpArray seismic network starting date – all of our 30 stations are fully operational. Four stations (A002A, A005A, A011A, A024A) have been moved to new sites in June 2016 because their noise levels were unacceptable (see below). They were replaced by stations A002B, A005B, A011B, A024B, respectively which perform much better than the previous site.
In the following we briefly describe each station in terms of sensor
installation, ground type, housing characteristics and the geological
setting. Station pictures and aerial views, as well as noise plots of all
stations are available in the online material. Please note that stations
pictures, aerial and map views, as well as sensor housing and geological
descriptions for all stations are also available online at the European
Station Book hosted by the ODC:
-
A001A is located inside a small abandoned WW2 bunker, that is built on a limestone formation within a gentle hillside. The sensor is put directly onto the bunker concrete floor in a corner furthest from any window or entry. The site is surrounded by vineyards and lies 700 m outside a small village and 300 m from the nearest road. This station shows the second lowest (best) noise levels of all stations. A001A is powered by two 100 W solar panels.
-
A002A was placed inside the basement of an abandoned workers residential building (3 floors, 30 10 m). The sensor was put on the screed floor. The site is located in the flat part of the Vienna basin with the geology dominated by soft sand-like sediments. It was 300 m from a village, 300 m from busy railways and next to a mining road which was heavily used by trucks. This station was replaced by A002B because it did not meet the noise requirements and was unsafe.
-
A002B replaced A002A. The station is installed inside an abandoned wine cellar, approximately 10 m below the free surface and 20 m from the entrance. The sensor is placed on a concrete base filled into a hole approximately 60 cm deep. The styrofoam box is buried by the soft fine grained sand/clay sediments which form the dominant geology around. The site is located at the foot of a narrow chain of hills and at the edge of a small village and 700 m from an oil field in production. The site shows elevated high frequency noise levels (similar to A002A) but satisfying long period performance.
-
A003A is placed on surface level inside a barely used farm storage building (1 floor, 100 10 m). The sensor is placed on a small patch of concrete attached to one of the inside walls. Geologically the site is part of the flat Little Hungarian plain, which is part of the Pannonian basin. This station is 4 km from a wind turbine park (38 turbines, 114 MW). The noise spectrum shows anomalous high frequency noise peaks and strong horizontal long period variation.
-
A004A is installed in the basement of an inhabited castle (4–5 floors, 50 50 m) which is located inside a village. The site is located inside the flat part of the Vienna basin and dominated by sediments. Consequently this station shows elevated noise levels.
-
A005A was located inside a small village, sheltered by a brick hut (2 2 m). The sensor was put on the concrete floor at ground level. The station suffered from strong anthropogenic and long period noise. This station was replaced by A005B because it did not meet the noise requirements.
-
A005B replaced A005A because it did not meet the noise requirements. The sensor is installed inside an unused underground storage cellar on rather solid ground, which is however not rock. The site is part of the Danube flood plain and thus dominated by river sediments. Regarding the site conditions, noise levels are satisfactory. High frequency noise ranges between the NHNM and the 20 dB requirement, but the long period noise levels are met.
-
A006A is inside an abandoned wine cellar, approximately 4 m below the free surface. The sensor is placed on a concrete base built into hardened soil ground of Loess type geology of hillside morphology. The site is 200 m outside a small village and 300 m from a road. Despite the underground installation this site suffers from rather high short and long period noise.
-
A007A is located in the basement of the entrance building (1 floor, 15 10 m) of an occasionally inhabited castle. The sensor is put on the screed floor, which has direct contact to the host rock. Few residential houses are near the castle, but still this site shows the best noise levels of all stations.
-
A008A is sheltered by a small wooden hut (2 2 m) and the sensor is put onto a big concrete base built into the foundation of the hut (on ground level). The site lies inside a small depression and is close to a flooding protection facility 200 m outside a small village. The surrounding vineyard hillside is dominated by clay and sedimentary geology. Despite the rather exposed surface installation the station meets all noise requirements.
-
A009A is placed at the end of an underground storage built 3 m into a hill slope and approximately 2 m below the surface. The sensor is put onto the concrete floor. Above the storage cellar there is a wooden hut (3 4 m) hosting a small telescope for private use. The site is next to a stand-alone residential house but 600 m from the next settlement. This station satisfies all noise requirements.
-
A010A is installed in the basement of an unfinished residential house (1 floor, 9 20 m). The sensor is put on the concrete (or screed) floor. The site locates in flat silt-type geology and is 1 km from a town and 500 m from a busy road. High frequency noise levels are elevated during daytime but otherwise the noise levels are satisfactory. The station is powered by two 100 W solar panels.
-
A011A is on ground floor inside a partly derelict house (1 floor, 6 6 m) in the forest. The local geology is of silt type and the morphology is hillside. The site is 400 m from a busy road and 800 m from industrial facilities. Noise levels were rather high and this station was relocated in June 2016.
-
A011B replaced A011A and is installed on a hill inside a small and rarely used chapel (20 8 m). The local geology is of silt type and the morphology is hillside. The chapel is 50 m from a small settlement and 300 m from a road. All noise requirements are met.
-
A012A is located inside a wooden mountain hut (1 floor, 5 10 m) that is built into a rather steep hill slope and surrounded only by forest (4 km from the nearest village), inaccessible to the public. The sensor is put onto the concrete foundation (on ground level) which reaches into the hut at the chimney. Because of the remote location, high frequency noise is low, as expected, but the station suffers from rather strong and strongly varying long period noise. This station is powered by one 100 W solar panel and a fuel cell, which is approximately 3 m from the sensor.
-
A013A is placed in the basement of an abandoned farm building (2 floors, 35 25 m). The sensor is put on the screed/concrete floor. The site is located inside steep to gentle hillside. A neighboring farm is 150 m far and the site is 50 m from a road but otherwise there is little surrounding population. Expect for strongly varying horizontal long period noise the site shows good noise levels.
-
A014A is installed in the basement of an uninhabited farm house which is used for storage (2 floors, 30 30 m). The sensor is placed on a concrete base which is built into clay. The site locates on a slope in hillside terrain. Few inhabited houses surround the station and it is 400 m from a sawmill and a busy road. Except for the East component, where noise is 10–20 dB higher than on the North component, this station meets all noise requirements.
-
A016A is inside a community fire house (2 floors, 10 20 m). The sensor is placed on tiles on ground floor level close to the outside walls. The site is located on top of a ridge in hillside terrain, surrounded by several residential and community buildings and 70 m from a road. Despite the location inside a settlement high frequency noise levels are low. However, horizontal long period noise is strong and strongly varying.
-
A017A is sheltered by a small abandoned brick/concrete hut built into a steep slope (6 4 m). The site locates on a very steep boundary flank of a hill formation (200 m elevation with respect to valley level) and 600 m from the outskirts of a village. The sensor is placed onto the screed/concrete floor (see Fig. ). Noise levels are good except for strong and strongly varying horizontal long period noise. The station is powered by one 100 W solar panel and a fuel cell which is 5 m from the sensor.
-
A018A is located inside a wooden house (1 floor, 18 8 m) which is used for storage. The sensor (on ground level) is put on the concrete foundation of the house, close to an outside wall. The site lies inside a river valley, on top of ancient river terraces. The station is 150 m from a river and neighbored by 4 similar uninhabited houses but otherwise far from any settlements. Although the station is affected by varying horizontal long period noise it mostly meets even the horizontal noise requirements.
-
A019A is installed on ground level inside a hut (7 5 m) which is close to a bigger wooden holiday house. The sensor is placed on the concrete/screed ground close to the barely isolating outside walls. The site locates on a steep slope in mountain terrain. It is 700 m from a quarry of unknown activity but otherwise far from any settlements. Noise levels are low except strong horizontal long period noise. The station is powered by two 100 W solar panels.
-
A020A is placed at ground level inside an unused barn and agricultural storage building (30 23 m) close to one inhabited house. The sensor is placed onto the concrete floor, close to an outside wall. The site is located inside hillside with scattered residential houses. The closest neighboring house is 150 m far and a village with industry is 2.5 km far. The station fulfills the high frequency requirements during quite times and show varying horizontal long period noise.
-
A021A is located on the edge of a cemetery and sheltered by a small brick hut (5 5 m) used for storage. The sensor is placed on the concrete/screed floor. The site situates in flat hillside dominated by clays. There is a residential building 50 m from the hut and it is 250 m to a village and a road. High frequency noise limits are met at night and long period noise is mainly within the noise requirements.
-
A024A is installed in an unused room in the basement of an inhabited farm house (65 40 m). The sensor is placed on the concrete floor. The site locates inside a flat Molasse type geology. The farm is surrounded by agriculture and in between two railways, 200 and 350 m far, respectively. The site exceeds the high frequency noise limits but performs well on all components in the long period range. Since railtraffic was too busy, this station was relocated in August 2016.
-
A024B replaced A024A and is placed in a 2 m deep pit inside an inhabited farm building (2 floors, 70 40 m). The sensor is located in an unused part of the house, with no regular activity. The surrounding morphology is hillside shaped by ancient glacial deposits (conglomerate). The farm is surrounded by fields and agriculture but otherwise far from any bigger settlement or road. First noise spectra show good long period performance and high frequency noise between 10 and 20 dB less than the NHNM.
-
A331A is located in a cellar of a cemetery house (10 6 m), slightly under surface level in a hill. The sensor is placed on the concrete floor. The site lies inside sandstone dominated hillside and is just on the edge of a small village. This site meets all noise requirements.
Examples of probabilistic power spectral densities for the three quality groups. First row (green): Example of a station (A007A) which meets the noise requirements at all times on all components. Middle row (orange): Example of a station (A020A) which partly meets the noise limits on some components and shows strong variation in long period horizontal noise. Bottom row (red): Example for a station (A339A) which on most components exceeds the noise limits. Solid lines mark the NHNM and NLNM noise models . Dashed lines mark the NHNM-20 and -10 dB noise limits, respectively, and the vertical line at 60 s period marks the corner frequency of our instruments. All graphs were calculated for the timespan January–May 2016. Please find individual graphs for all stations in the Supplement.
[Figure omitted. See PDF]
-
A332A is installed at surface level of a large cemetery house (20 13 m) that contains a church tower with a bell ringing four times a day. The sensor is placed on the tiles of a rarely visited cleaning storage room. The site is surrounded by hilly landscape created by alluvial deposits. Noise limits are kept except for horizontal long periods, which are strong and strongly varying.
-
A333A is placed in the cellar of rarely used distillery house (28 24 m). The sensor is put on the concrete floor. The site lies within plain sand like sediments near the borders of a small town. The site suffers from elevated high frequency noise and only for some times can fulfill the long period requirements on the horizontal components.
-
A334A is put at the ground level in a small cemetery house (10 7 m). The sensor is placed onto the tile floor. The site is inside hillside of Loess type geology and lies at the edge of a small village. There is a quarry at 2.5 km distance. The noise spectrum of this station is affected by few artificial peaks in both high and low frequencies and rather strong horizontal long period noise. Consequently this stations meets the noise requirements only during quiet times for some of the components.
-
A335A is installed 2 m under the surface level in a pit inside an unused electric controlling house (6 6 m). The sensor is placed onto the concrete ground. The site is at a tree nursery in the middle of a large forest and 1.5 km from the closest populated area. High frequency noise is acceptable but long period noise varies strongly on all components.
-
A336A is approximately 10 m under the surface in a wine cellar 10 m from the entrance. The sensor is placed directly on the hard volcanic type rock. The site lies at the edge of a small village, 100 m from a road and 50 m from a river. High frequency noise is within the limits but horizontal long period noise partly exceeds the limits. Notably here is a substantial difference in noise levels among the two horizontal components, one of which (component 3/supposedly E) shows strong separation into two noise branches (see the Supplement).
-
A337A is installed 2 m under the surface level in a big unused agricultural storage house (40 13 m). The sensor is placed at the concrete floor. The station is situated in the sedimentary plain of a river, at the edge of a village and 800 m from a dammed river reservoir. Except for vertical long period all noise limits are exceeded.
-
A338A is located at the ground level in a cemetery house (15 15 m). The sensor is installed on the concrete floor. The site lies inside clay dominated hillside and just outside a small village. Noise requirements are partly met for high frequencies but horizontal long period noise is strongly varying.
Map visualizing which stations meet the noise requirements. Color coding follows the listing in Table . The evaluation of the noise levels is based on five months of data from January–May 2016 (except for the B stations, which were judged from first data in June/August). The arrows inside the red dots indicate the true orientation of the sensor. Thick arrows denote sensors within 5 deviation from geometrical North (and channels named HHN, HHE) while outlined arrows mark sensors with a greater deviation from true North (and channels named HH2, HH3). For station A024B, the correct orientation was not checked with a gyrocompass, yet.
[Figure omitted. See PDF]
This table summarizes the noise performance of all stations by components. Green fields indicate that the noise limits are met, orange fields denote that the noise requirement are partly exceeded and red fields mark components which do not satisfy the noise requirements. The color of the station name relates to the coloring in Fig. and judges the overall noise performance of any given station. The stations with grey italic text (A002A, A005A, A011A, A024A) have been removed and replaced by respective stations with B as last letter. The evaluation of the noise levels is based on five months of data from January–May 2016 (except for the B stations, which were judged from first data in June/August).
[Figure omitted. See PDF]
-
A339A is placed 2 m under the surface level in a cellar of an unused storage building (25 5 m) of an operating chicken farm. The sensor is placed onto a tile floor. The site lies within the all flat danube flood plain 3 km from the danube and 800 m from a village. Long period vertical noise limits are met, but all other noise requirements are strongly exceeded.
Noise performance
We classify the noise performance of our stations into three groups,
according to the noise requirements set by the AlpArray Working Group.
Stations that fulfill the noise requirements (see Sect. ) in
both frequency ranges (1–20 Hz and 30–200 s) for most of the components at all times fall into group green. If only
some components (e.g. the vertical) meet the required noise levels for some
of the frequency ranges or if there is strong temporal variation (e.g.
anthropogenic noise with day/night cycle) in the noise levels, the station
falls into group orange. Group red contains stations which do not meet the
noise requirements for most of the components in both frequency ranges.
Figure shows examples of probabilistic power spectral
density plots for each group and Fig. visualizes which
stations meet the noise requirement and which don not.
Table
summarizes the noise performance of all 30 stations by the individual
components. Individual power spectral density graphs (calculated from five
months of data, January–May 2016) are available in the online
material. Updated monthly power spectral density plots for our AlpArray
stations are available at
To summarize, in the high frequency range (1–20 Hz) 50 % of our stations are at least 20 dB below the NHNM on both vertical and horizontal components. 25 % of the stations meet the limits during quiet times (i.e. at night) and another 25 % are affected by strong high frequency noise and cannot fulfill the noise requirements. The latter stations are almost exclusively located in sedimentary basins and/or close to anthropogenic noise sources.
In the long period range (30–200 s) noise performance clearly separates into vertical and horizontal components. On the vertical component all stations show noise levels of 20 dB below the NHNM or better and thus meet the AlpArray noise requirements. However, many stations are affected by rather strong horizontal long period noise. For most of the stations, horizontal noise is up to several tens of dB higher than the vertical noise level. Still, 30 % of the stations satisfy the requirements on the horizontal components, but another 30 % experience noise levels in the range of the NHNM or higher. 40 % of the stations show strong variations in horizontal noise (see orange example, A020A in Fig. ) and only during unspecifiable quiet times meet the noise requirements.
We cannot relate the susceptibility of a station to long period horizontal noise to a specific housing type. Among the well performing stations are those in well-isolated underground shelters as well as surface stations inside big or small aperture buildings or huts. Similarly there is no clear relation between sensor shelter and strong or strongly varying long period noise. We do note, however, that for the majority of stations vertical noise levels are much lower (up to several tens of dB) than horizontal noise levels. Additionally, for some sites we observe up to 20 dB difference in noise levels between the two horizontal components. This may reflect local site conditions or effects which should be studied further. Since our stations are not pressure sealed or installed on rigid baseplates they might be affected by pressure variations and long period surface tilt . The latter may in particular cause the elevated horizontal noise levels (compared to vertical) on our stations since almost all of them are surface or near surface installations. Additionally, most stations are located inside 1–2 floors buildings which may pick up e.g. wind or temperature variations and thus create additional long period noise. However, even some of the well-performing sensors are located on surface level inside buildings. Convection in the surroundings of the sensor seems unlikely to be a dominant long period noise source since even some basement stations with almost constant temperature are affected. Convection inside the styrofoam box should be minimal due to the silicon sealing and little free space between the textile cover of the sensor and the styrofoam insulation box (see Fig. ).
determined the vertical self-noise of our Reftek 151 60s A generation sensors. They show self-noise levels below the NLNM for the flat part of the instrument velocity response down to the specified effective eigenperiod of 60 s. At 200 s the sensor self-noise is 15 dB higher than at 60 s and exceeding the NLNM model. During personal communication they report occasional sequences of instability for generation A sensors with elevated self-noise levels for periods longer than the effective sensor eigenperiod. Still, the measured self-noise for the Reftek 151 60s A sensors for periods between 60 and 200 s is well below the horizontal long period noise levels we encounter in our deployments. Additionally, for stations affected by strong horizontal long period noise, the noise levels are elevated for all periods below 10s and the stations in question are equipped with both Reftek 151 A and B sensor generations. Hence, we conclude that the horizontal long period noise levels are not due to exceeding the sensor specified frequency range but rather due to housing and surface effects.
The majority of our stations is installed within sedimentary surface layers of unknown thickness and only few stations have direct contact to host rock. point out significant diurnal variation in horizontal long period noise for shallow temporary vault installations inside thick layers of soft sediments. They relate the noise variations to the soil responding mainly to atmospheric pressure variations. We did not perform a detailed study of potential diurnal variations in noise levels for our stations, yet, but the strong variability seen in some of the probabilistic power spectral densities (calculated for 5 months, winter to spring) may reflect a similar effect. report similar variations for long period horizontal noise and suggest that for for sites in sedimentary geologies direct burial of broadband sensors may be favorable over vault emplacement.
Conclusions
The Department of Meteorology and Geophysics of the University of Vienna started deploying temporary broadband stations for the AlpArray project in early 2015. Since January 2016 thirty seismic stations equipped with Reftek 151 60s sensors and Reftek 130(S) data loggers are fully operational and sending 100 sps waveform streams to the ODC in real-time, using the cellular network. Since January 2016 we retrieve almost 99 % of the data in real-time. Our stations follow a low-cost installation design and are usually placed inside basements of uninhabited houses, huts, cellars or castles. The sensor, insulated with a microfleece bag and a styrofoam box, is commonly put on concrete ground or tiles and in few cases on top of a constructed concrete base in soil. Most stations are powered through the power grid, while few stations feature a 2 100 W solar panels installation or one 100 W panel and a fuel cell.
With such design 50 % of the stations show high-frequency (1–20 Hz) noise levels which are 20 dB below the NHNM or less on all components. Another 30 % reach the NHNM – 20 dB noise performance during quiet times (i.e. at night). All stations perform well for vertical long period (30–200 s) signals with noise levels 20 dB below the NHNM or less. However, horizontal long period noise levels are generally much stronger than the verticals and only 30 % of our stations meet the NHNM – 10 dB requirements for horizontal long period noise. 40 % of the stations are affected by strongly varying long period horizontal noise. This is likely due to the fact that all stations are surface or near surface stations inside or near the footprint of an artificial structure such as a building. Hence, our stations are affected by long period surface tilt introduced by e.g. atmospheric pressure variations and little or no efforts to minimize such effects were made for these temporary deployments.
Overall our low-cost deployment provides reliable and continuous seismic data of good quality in real-time and forms one integral part of the greater AlpArray seismic instrumentation. In particular, data from our stations will help to resolve outstanding questions and debates about the geological structures under the Eastern Alps, which is one of the key scientific targets of AlpArray.
Data availability
Seismic data used for this manuscript is currently not publicly accessible by
decision of the AlpArray Working Group. Currently, all waveform data is
exclusively available to registered members of the core group of the AlpArray
seismic network. Please visit
The Supplement related to this article is available online at
F. Fuchs prepared the manuscript with contributions from all co-authors, coordinated the station deployments and manages data flow and quality control. P. Kolinsky and G. Gröschl scouted and deployed the majority of the seismic stations. G. Bokelmann is the principal investigator of AlpArray Austria and supervises the project. The AlpArray Working Group worked out the network layout, quality guidelines and standards for the seismic data exchange.
Acknowledgements
AlpArray Austria is funded by the FWF Austrian Science Fund project number P26391. We acknowledge planning and organization of the AlpArray coordinators Edi Kissling, György Hetenyi, Irene Molinari and John Clinton at ETH Zürich, Switzerland, who created the AlpArray seismic network layout. We gratefully acknowledge support of the Institute of Geophysics of the Czech Academy of Sciences for providing the fibreoptic gyrocompass. We thank Johann Huber for technical assistance and Maria-Theresia Apoloner for software assistance and help in the field. Herta Gassner is thanked for her administrational help. Felix Schneider, Ehsan Qorbani, Sven Schippkus and Eric Löberich are thanked for their help in the field. We thank all involved Austrian and Slovakian communities, forest administrations and individuals for their help during site scouting. We acknowledge help of the Slovak Academy of Sciences for operating the telemetry in Slovakia. We thank Aladino Govoni and one anonymous reviewer for their suggestions to improve the manuscript. Edited by: D. Pesaresi Reviewed by: A. Govoni and one anonymous referee
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
© 2016. This work is published under http://creativecommons.org/licenses/by/3.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.
Abstract
We report the technical realization and performance of thirty temporary seismic broadband deployments for the AlpArray project in eastern Austria and western Slovakia. Reftek 151 60s sensors and Reftek 130/130S digitizers form the core instrumentation of our seismic stations; these are mostly installed inside abandoned or occasionally used basements or cellars in small buildings or huts. We describe our type of installation and briefly introduce the site conditions for each of the thirty installations. We present a probabilistic power spectral density analysis to assess the noise conditions at all sites and potential relations to the installation design.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer