Introduction
Aerosol–cloud interactions are a major source of uncertainties in the quantification of climate forcing of aerosols . The wet size of an aerosol particle when at equilibrium with the environment is governed by Köhler theory and depends on particle size and composition. In the atmosphere, activation of cloud condensation nuclei (CCN) is a competition between aerosol particles for water vapor, influenced by dynamical processes and the kinetics of particle growth and dependent on the updraft velocities, aerosol number concentrations and differences in size and composition of aerosol particles . Although our understanding of the processes involved in aerosol activation has increased considerably in recent years , the inclusion of all the detailed information that might be available about aerosol populations into global and regional circulation models is often impractical. Thus, assessments of the uncertainties derived from simplifications assumed are relevant and potentially contribute to the discussion on the level of sophistication required by general circulation models (GCMs) with the aim of decreasing the uncertainties.
A large quantity of aerosol particles is generated globally by open biomass
burning , and the impacts of
smoke aerosols in climate, air quality and geochemistry have being addressed
in several studies
Even though a large fraction of biomass burning aerosols has low to moderate hygroscopicity , biomass burning particles can act as CCN under sufficiently high atmospheric water vapor supersaturations . Therefore, CCN activation properties of pyrogenic particles are likely to be relevant for the aerosol climate forcing.
Some external mixing in terms of hygroscopicity seems to be rather common in aerosol populations, particularly over continents . However, average hygroscopicity parameters have been estimated from both observational and modeled data assuming internal mixing for aerosols from the same emission source (e.g., biomass burning), or even within the same geographical region . Sensitivity of CCN activation to hygroscopic mixing state under equilibrium conditions is also significant, and the assumption of total internal mixing could result in an overestimation of the CCN population that can range from 10 to 100 % . The impact of mixing state under dynamic conditions has, however, been less studied, and some evidence suggests that conclusions from equilibrium conditions might not be directly extrapolated to CCN activation during cloud formation .
The aerosol particle's composition is known to influence the particle water uptake and CCN activation . Although the effects of composition on the cloud droplet number concentrations are typically secondary when compared to those of population number concentration and size distribution , the extent to which these effects can be safely neglected in GCMs is also yet to be established. Droplet number concentrations were shown to be more sensitive to the presence of organic content than to the updraft velocity in some situations . On conditions typical of pyrocumulus (number concentrations up to and updraft velocities up to 20 ), found that cloud droplet number concentration was sensitive to compositional effects (hygroscopicity). For three different ratios of the aerosol number concentrations to the updraft velocity, and for a fixed aerosol size distribution, the authors found that the sensitivity to hygroscopicity was low for medium to high hygroscopic values, but moderate for very low and low hygroscopicity values . Still, sensitivities to hygroscopicity are likely to be tightly related to the position of the dry critical size of the smallest activated particle within the overall size distribution of the aerosol population, and significant sensitivities have been obtained for the population of small aerosol particles with medium and high hygroscopicity .
Aerosol particles with critical supersaturations smaller than the maximum supersaturation reached within the cloud can nonetheless become interstitial aerosols due to the evaporation and deactivation mechanisms described by . These kinetic limitations, sometimes neglected in GCMs, are expected to be large when significant aerosol loads are present . Consequently, parameterizations that assume equilibrium conditions overestimate CCN when kinetic limitations are important . However, little is known about how kinetic limitations are related with the particle hygroscopicity, although a relation between the timescale of the components solubility and activation has been reported .
On the other hand, several observational biomass burning studies conducted in the Amazon region reported rather similar number size distributions for biomass burning aerosols within the boundary layer . In terms of hygroscopicity, these smoke particles have been found to be externally mixed . Their population effective hygroscopicity parameter, converted from the original data using expressions suggested by , ranged between 0.05 and 0.13 ; these compare well with observed values for biomass burning aerosols but are rather on the lower side of the range of values reported elsewhere. Reported values of the hygroscopicity parameter for freshly emitted smoke particles in biomass burning laboratory experiments reached values up to 0.6, although a significant number of data indicated values between 0.02 and 0.2, with wood species and smoldering fires producing the less hygroscopic particles . An average hygroscopicity parameter of 0.21 was obtained for a 4-day biomass burning episode near Guangzhou, China, using airborne data . The hygroscopicity parameter obtained from CCN airborne measurements for boreal fires biomass burning aerosols in Canada was 0.18 for both recently emitted and aged aerosols, while the values estimated assuming an average chemical composition were, on average, 0.11 for fresh aerosol particles and 0.24 for aged ones, both within the level of variability in the value estimated from CCN measurements . A recent study of the hygroscopicity of recently emitted and aged smoke particles reported ranging between 0.05 and 0.1 for the same parameter in Thailand .
In the present study, we used an adiabatic cloud model to simulate the CCN activation of biomass burning particles, aiming to contribute to the understanding of the possible impact of different hygroscopicity values, mixing state and kinetic limitations in the CCN activated fraction. The modeling approach followed is described in Sect. 2. According to the available observations of biomass burning aerosols in the Amazon region, three typical situations in terms of size distributions and other aerosol parameters were considered in the definition of the case studies and other simulation parameters, as described in Sect. 3. Finally, the results from the cloud parcel model and our conclusions are discussed in Sects. 4 and 5.
Modeling approach
Cloud parcel model
A model of an air parcel assumed to ascend adiabatically at a prescribed updraft velocity and without entrainment to supersaturation conditions was used to study the activation of aerosol particles in the first stages of cloud development. The air parcel model used in this work is based on the model described by , with the supersaturation and liquid water mixing ratio tendencies estimated as in and the equilibrium supersaturation calculated as proposed by using the hygroscopicity parameter . The pressure is estimated assuming the environment is in hydrostatic equilibrium, and the temperature and water vapor mixing ratio are estimated from the moisture and heat conservation, respectively . The surface tension dependence on temperature is relevant to CCN activation , and it is calculated as .
The aerosol dry size distribution for each hygroscopic group is discretized into () bins with a fixed volume ratio for all bins. Particles that belong to bin size () and hygroscopic group (hg) are assumed to grow equally when exposed to the same conditions. Coagulation and coalescence processes are not considered, so the number of particles in each bin remains constant while their wet sizes change over time (full-moving size structure) . In this work, the particle's critical diameter is determined for each bin size and hygroscopic group as the value that maximized the particle's equilibrium supersaturation. Aerosol particles with wet size larger than their critical size are considered activated. Particles larger than strictly activated particles are considered cloud droplets as well because they have wet sizes larger than that of cloud droplets and can condense significant quantities of water vapor on their surfaces . The total cloud droplet number concentration estimated without assuming equilibrium conditions, , is the sum of strictly activated particles and those with wet sizes larger than activated particles. To abbreviate the notation, hereafter will refer to at the end of the simulation, unless otherwise stated.
Some parameterizations of CCN activation neglect kinetic limitations
. A notable example of one such parameterization is the
one proposed by , widely used in
GCMs
If particles are presumed to respond instantly to changes in the air parcel supersaturation, particles with critical supersaturation lower than a given supersaturation will also have dry sizes larger than a dry particle cut diameter (details in Appendix B). The cloud droplet concentration estimated thus, here denoted , effectively represent the maximum cloud droplet concentration attainable at supersaturation . If evaporation and deactivation mechanisms of kinetic limitations are significant, the calculation of the cloud droplet spectra from the maximum supersaturation assuming equilibrium will lead to an overestimation of the cloud droplet number concentration. In an intermediate approach, particles can be considered cloud droplets if their wet diameters are larger than the approximate cut wet diameter that corresponds to in equilibrium conditions (Appendix B). This approximate estimation, denoted , considers kinetic effects to some extent since the wet sizes of particles that are compared to are calculated explicitly in the cloud model. In order to measure the impact of kinetic limitations in the simulations, estimations by the three aforementioned methods are presented. In addition, the ratio between the equilibrium droplet concentration corresponding to the maximum supersaturation and the droplet concentration, , was estimated at the time of maximum supersaturation and at the end of the simulation.
The cloud parcel model described was fully implemented in Mathematica® 10.0 . Equations for the size of particles in each bin, supersaturation, liquid water mixing ratio, water vapor mixing ratio, air pressure and temperature form a closed system of nonlinear ordinary differential equations (ODEs) in which derivatives depend not only on the set of variables but also on their derivatives as well. The ODE system was solved using the IDA method from SUNDIAL package (SUite of Nonlinear and DIfferential/ALgebraic equation Solvers) , as implemented in the function NDSOLVE of Mathematica. Symbols frequently mentioned in this section and through the text are summarized in Appendix A.
Sensitivity of CCN to a parameter
Sensitivities in the context of CCN activation were first introduced by as the slope in the linear regression to the logarithms of cloud-top effective droplet radius as a function of the logarithms of the parameter , i.e., . Later on, proposed sensitivities of the droplet number concentration to a parameter :
According to Eq. (), and a sensitivity closer to zero indicate a smaller increase in as parameter increases. Sensitivities were calculated from linear regressions in vs. curves as averages (slope of the linear fit) and locally (derivatives of the curves in the space).
Parameters for the Aitken and accumulation lognormal number size distribution for the defined case studies.
() | () | ||
---|---|---|---|
Case MP | |||
Aitken | 5000 | 95 | 1.60 |
Accumulation | 1000 | 180 | 1.50 |
Case MP | |||
Aitken | 1000 | 95 | 1.60 |
Accumulation | 5000 | 180 | 1.50 |
Case HP | |||
Aitken | 5000 | 95 | 1.60 |
Accumulation | 5000 | 180 | 1.50 |
Definition of case studies and simulation parameters
In this work, three hypothetical different size distributions were defined as case studies for the cloud model simulations (Table ). The corresponding number size distributions are depicted in Fig. . The parameters of the selected size distributions were chosen as to resemble biomass burning aerosol observations in Amazonia (resumed in Table S1 of the Supplement) while trying to minimize the impact of particle size and standard deviation. The first case is a moderately polluted case with 5000 particles in the Aitken mode, and 1000 in the accumulation modes, respectively (MP) (Fig. a). Case MP is similar to the observed distribution during the SAMBBA experiment (South American Biomass Burning Analysis, 2012) . The second is a case study with the same number concentration than MP, but with higher number of particles in the accumulation mode, with 1000 and 5000 in the accumulation and Aitken modes, respectively (MP) (Fig. b). The size distribution of case MP is comparable to the observed during LBA-SMOCC (Large-Scale Biosphere Atmosphere Experiment in Amazonia – Smoke Aerosols, Clouds, Rainfall, and Climate, 2002) dry-to-wet transition period. There was also a predominance of particles in the accumulation mode during the biomass burning episodes of LBA-CLAIRE (Cooperative LBA Airborne Regional Experiment, 2001) , although particle number concentrations were lower for these periods. Finally, the last case is a highly polluted case (HP) (Fig. c) with 5000 in both modes, resembling the observed distribution during the SMOCC dry period , minus the nucleation mode. Particles in the nucleation mode are not expected to impact significantly the CCN behavior of the aerosol population and were disregarded.
In both CLAIRE and SMOCC experiments, smoke particles were found to be externally mixed in terms of hygroscopicity . The less hygroscopic group presented very low hygroscopicity values, between 0.032 and 0.068, while the values for the more hygroscopic group were low, ranging between 0.110 and 0.172 (Table S2 of Supplement). Here, the following classification by was considered: very low hygroscopicity (VLH, ), low hygroscopicity (LH, ), medium hygroscopicity (MH, ) and high hygroscopicity (HH, ). Neither set of observations included smoke particles with . The hygroscopic group number fractions varied, with very low hygroscopicity particles accounting for 20 % of the total number concentration , or up to 85 % (Table S2). As a result, the population effective hygroscopicity parameter ranged between 0.05 and 0.13.
Schematic number size distributions for MP (a), MP (b) and HP (c) case studies. Total population (black, solid), Aitken (red, solid) and accumulation (blue, solid) modes are indicated. Particles in hygroscopic group (dashed line, all colors) are also shown for a population average .
[Figure omitted. See PDF]
To assess the role of aerosol mixing state outside equilibrium conditions, cloud model simulations were conducted for populations both externally and internally mixed. The variability in the population effective was simulated assuming that the population is composed by two populations externally mixed in terms of hygroscopicity, having and , respectively, with a resultant population effective hygroscopicity estimated as that varies according to the number fraction of each hygroscopic group, hg (Table ). This case is denoted Ext. A second possibility, denoted Ext, was considered to account for more hygroscopic biomass burning aerosols observed for other biomass/regions. In this second case, the of the more hygroscopic group is increased from to a medium hygroscopicity value, , with a resultant population effective hygroscopicity also varying according to the number fraction of each hygroscopic group (Table ). Finally, the internally mixed population was denoted Int. Results obtained for two hygroscopic groups of particles externally mixed are compared with results obtained if the population is assumed to be internally mixed. The minimum/maximum in both sets of externally mixed populations is reached for the extreme case when only one group is present (therefore reducing to the internally mixed case) and is equal to the hygroscopicity parameter of particles in this group.
Number fractions for the hygroscopic groups in the externally mixed populations Ext and Ext.
Ext | Ext | |||
---|---|---|---|---|
0.04 | 1.00 | 0.00 | 1.00 | 0.00 |
0.06 | 0.83 | 0.17 | 0.92 | 0.08 |
0.08 | 0.67 | 0.33 | 0.85 | 0.15 |
0.10 | 0.50 | 0.50 | 0.77 | 0.23 |
0.12 | 0.33 | 0.67 | 0.69 | 0.31 |
0.14 | 0.17 | 0.83 | 0.62 | 0.38 |
0.16 | 0.00 | 1.00 | 0.54 | 0.46 |
0.18 | – | – | 0.46 | 0.54 |
0.20 | – | – | 0.38 | 0.62 |
0.25 | – | – | 0.19 | 0.81 |
0.30 | – | – | 0.00 | 1.00 |
The effective and the corresponding fractions of each group for both situations and different fractions of the hygroscopic groups are presented in Table . The schematic size distribution of the aerosol total population and that of the hygroscopic group with are indicated in Fig. 1 for the three case studies, for a and Ext external mixing state. The aerosol composition was considered to be independent of particle size, assuming that the slight tendency of higher hygroscopicity of larger particles (Table S2) was typically not large enough to impact significantly the CCN behavior of the population. Simulations were conducted for the internally mixed population (Int) with hygroscopicities that ranged from to , for the defined MP, MP and HP cases, in order to analyze the effect of hygroscopicity. Simulations conducted for the externally mixed population (Ext and Ext) ranged between the minimum and maximum (0.04 to 0.16 and 0.04 to 0.30, respectively).
Updraft velocities between 0.1 and 10 were considered. Higher number concentrations than considered here can be found in pyrocumulus, but it is probably safe to assume that their impact on the hydrological cycle and aerosol indirect effect on a regional scale is secondary when compared with that of the regional haze, so these extreme cases of polluted conditions were not covered in our study. According to the regimes proposed by , our study focused largely on the aerosol-limited and aerosol- and updraft-sensitive regimes, with particle number concentrations that characterize polluted conditions like those found in the regional haze. For MP and MP cases, the updraft-limited case is given approximately by , but the aerosol-limited is given by . For the HP case, the approximate limit of the updraft-limited case is given by , and the aerosol-limited by (not considered in our simulations).
Cloud-base initial conditions for the simulations were temperature of 293 , atmospheric pressure of 900 and relative humidity of 98 %. Sensitivity tests indicated only a weak dependence (absolute differences between maximum supersaturations obtained initializing at 80 and at 99 % below 0.03 %) of maximum supersaturations with the initial relative humidity for the highest updraft values, and a negligible effect in the activated fraction (see Fig. S1 of the Supplement). To avoid unrealistic physical parameters, the final time of simulation was defined somewhat arbitrarily as the time required for the parcel to ascend 500 at the considered updraft velocity. The parameters for the simulations are summarized in Table . The distribution was discretized into 1000 bins ranged from 15 to , leading to a relative error of less than 0.003 % with respect to the lognormal distribution for all the cases considered in this study. To exclude particles that are not large enough to activate, only particles larger than 30 () were considered as aerosol number concentrations in the calculation of fractions. For all the cases considered, the cloud nuclei larger than 30 fraction included almost all particles, with the lowest fraction obtained for case MP.
Parameters for the simulations.
Parameter | Value/range |
---|---|
Updraft velocity | 0.1–10 |
Hygroscopicity parameter | |
Int | 0.02–0.60 |
Ext | 0.04–0.16 |
Ext | 0.04–0.30 |
Initial conditions | |
Relative humidity | 98 % |
Temperature | 293 |
Atmospheric pressure | 900 |
Air parcel height | 500 |
Results and discussion
Maximum values of supersaturation and CCN activated fraction, as a function of hygroscopicity, updraft velocity and mixing state, are presented in Fig. for the various proposed case studies and mixing states. Due to the high particle number concentrations that characterize polluted conditions in the three case studies, maximum supersaturations reached in the simulations were typically low and, except for the highest updraft velocities and for very low hygroscopicity values (VLH, ), had values below 0.5 % in the MP case and below 0.4 % in the MP and HP cases. The highest values of maximum supersaturation were obtained for the MP case, with the majority of particles in the Aitken mode. Maximum supersaturations in this case were, on average, 0.10 % larger (absolute differences) than those obtained for MP case, and about 0.15 % higher than those obtained for HP case. Meanwhile, the values of maximum supersaturation reached in the MP case study were higher than those obtained in the HP case, but slightly higher, with absolute differences between maximum supersaturation values of up to 0.05 %, all else being equal, in spite of the much higher particle number concentrations in the latter case. The case study with the highest , HP, presented the largest cloud droplet number concentrations. However, the largest fractions were instead reached in the MP case, all else being equal. The activated fractions for the HP case were the lowest between all three cases for all values of within the low hygroscopicity (LH, ) and medium hygroscopicity (MH, ) ranges, while for in the VLH range the lowest fractions were obtained for the MP case.
Maximum supersaturation reached (top) and fraction of particles activated (bottom) for the internal mixing (solid line) and external mixing cases Ext (dotted line) and Ext (dashed line). Plots on columns (a, d), (b, e) and (c, e) are for MP, MP and HP case studies, respectively. The color scale refers to the updraft velocities from 0.1 to 10 .
[Figure omitted. See PDF]
These results for the maximum supersaturations and fractions are explained by the Köhler theory, which predicts that the Kelvin term typically dominates the growing process for larger particles, while the Raoult term is more relevant for smaller ones. Therefore, particles in the accumulation mode are likely to condense water vapor on their surfaces more readily than the comparatively smaller particles in the Aitken mode, growing larger and impacting the maximum supersaturation reached more than the latter. Moreover, the Raoult term is more significant the smaller the particle; thus, the activation of particles in the Aitken mode is expected to be more altered by hygroscopicity than the activation of particles in the accumulation mode.
Among the variable parameters within the simulations, both maximum supersaturations and fractions were impacted the most by updraft velocity, for all study cases and mixing states. Mean sensitivities of to in the MP, MP and HP study cases were 0.66, 0.65 and 0.73, respectively, with very little variability with mixing state, as illustrated in Fig. for . These mean values of are higher than previous estimations of 0.18 and 0.47 for clean ( 1000 ) and polluted (1000–3000 ) conditions, respectively, by . However, an increase in the sensitivity to with the number concentration is consistent with the behavior expected within the updraft- and aerosol-sensitive regime that is, on average, the predominating regime. The adjusted coefficients in the linear fits of the vs. curves were 0.90 for all cases and mixing states. However, the data points departed from the mean slope towards low and high updraft velocities for all case studies and mixing states (Fig. , top). Cloud droplet number concentrations were more sensitive (local up to 0.9) to increases in the updraft velocity for velocities within the updraft-limited regime, while for the aerosol-limited regime the sensitivity to decreased to values between 0.1 and 0.4 (Fig. , bottom). This varying sensitivity of to is in agreement with the changing behavior within each regime of CCN activation described by , which varies from a high sensitivity of activation with in the updraft-limited regime to almost no influence in the aerosol-limited one. The sensitivity of to the aerosol number concentrations and the geometric mean diameter and standard deviation have been discussed elsewhere and was not addressed here.
Number of particles activated (top) and sensitivity of to the updraft velocity (bottom) for , obtained for the MP (solid line), MP (dashed line) and HP (dotted line) case studies. Results for internal mixed Int population and externally mixed populations Ext and Ext are in black, red and blue, respectively.
[Figure omitted. See PDF]
Schematic number size distribution of particles activated in Ext (hatched area) and Int (grey area) mixing states, for an average and , for (a) MP, (b) MP and (c) HP case studies. Total aerosol population (black, solid line), hygroscopic group (black, dashed line) and maximum supersaturation reached in the simulations for each mixing state are indicated.
[Figure omitted. See PDF]
In contrast with , the sensitivity to hygroscopicity changed substantially with mixing state; this will be discussed in Sect. 4.2.
Aerosol mixing state
The aerosol mixing state modified both maximum supersaturations and activated fractions, although to different extents. The values of maximum supersaturation were slightly underestimated for updraft velocities in the aerosol-limited and the aerosol- and updraft-sensitive regimes when internal mixing was assumed (Fig. , top). The absolute differences were up to 0.01 and 0.03 % for the externally mixed Ext and Ext populations, respectively. For updraft velocities within the updraft-limited regime, however, the maximum supersaturation reached were lowest, and the values assuming an internal mixing were almost identical or marginally higher than those reached for externally mixed populations.
On the other hand, the internal mixing hypothesis typically led to overestimations of , regardless of the somewhat lower values of maximum supersaturation reached for this mixing case. The effect of hygroscopic mixing state in the CCN activation behavior of aerosols can be illustrated through the consideration of an aerosol population with known size and composition but no information on the mixing state. Particles in the externally mixed population will have either larger or smaller hygroscopicity parameters than that of the internally mixed population average. The more hygroscopic groups in the external mixture will have smaller cut particle diameters and will activate more readily than the internally mixed particles. Consequently, if internal mixing is presumed, the number of more hygroscopic particles that become cloud droplets would be underestimated.
Overestimation of when the aerosol is assumed internally mixed, calculated as a function of the hygroscopicity (color scale) and the updraft velocity, for the external mixing Ext (left) and Ext (right). Plots on panels (a, b), (c, d) and (e, f) correspond to MP, MP and HP case studies, respectively. Box plots on top of data represent the spread for different hygroscopicity parameters. The box boundaries delimitate the interquartile range and mean values are indicated by diamond symbols. Dashed lines represent the approximate boundaries between CCN activation regimes.
[Figure omitted. See PDF]
Although differences in activation for more and less hygroscopic particles due to internal mixing will contribute with opposite signs to the total derived from mixing state, they are unlikely to cancel each other out. In a simulation selected to illustrate the impact of mixing state in , an externally mixed population (Ext) has one hygroscopic group with , in the VLH range, present in a fraction , and a second hygroscopic group with , within the MH range, with . Assuming internal mixing (Int), these two groups resulted in (Table ). For this specific case, the schematic size distribution of particles that are activated as CCN in the MP, MP and HP case studies at a prescribed updraft velocity of are presented for external and internal mixtures in Fig. 4. The values of maximum supersaturations reached were somewhat lower when internal mixing state was assumed, between 2 and 3 % depending on the study case. A fraction of particles in the MH hygroscopic group () was indeed activated as CCN in the externally mixed Ext but was not in the internal mixing, since the internally mixed population is lower and thus the cut size for activation in the internally mixed population is larger. However, an even larger fraction of the particles in the VLH group were not activated in the external mixing, but these were considered as activated when an internal mixing state was assumed. Thus, in this example, and characteristically in the conducted simulations, assuming internal mixing for an externally mixed population led to an overestimation of .
Box plots on top of data in Fig. display the magnitude of the overestimation in if internal mixing is assumed for an externally mixed population, for the range of updraft velocities and . The overestimation of was expressed as , where and refer to estimations for internally and externally mixed populations, respectively, and the population is considered to be externally mixed. Overestimations of when assuming internal mixing were larger when the module of the difference between the internal mixture and that of the hygroscopic group with closest value of hygroscopicity in the external mixture was greater, i.e., when the internally mixed assumption was comparatively less valid. Overestimations close to the lower limit or below the interquartile range of CCN overestimations were obtained for populations with fractions in the Ext (with a resulting ), and in the Ext mixing (). Within the aerosol- and updraft-sensitive regime, the overestimations of were largest for all three cases. The higher number concentration of particles in the Aitken mode in the MP and HP case studies resulted in larger overestimations in the CCN number concentrations even for the upper range of updraft velocities. In contrast, the overestimations of decreased noticeably as the updraft velocity increased towards the aerosol-limited regime for the MP case. Within the updraft-limited regime the typically low fractions of activated particles, as well as the estimations of , were more susceptible to inaccuracies due to bin resolution.
Average overestimations of for the externally mixed population Ext were typically low, 5.7 2.4, 5.1 2.1 and 2.9 2.0 %, or the MP, MP and HP case studies. For population Ext, and the same case studies, averages were slightly higher, 12.4 4.7, 10.4 4.5 and 10.5 3.8 %, respectively. However, with particle number concentrations of 10 000 in the HP case and 6000 in the MP and MP case studies, the absolute overestimations () in the CCN number concentration for these cases were, respectively, 160 94, 181 96 and 224 137 for Ext simulations and 349 203, 358 188 and 467 272 for Ext. Maximum absolute overestimations were reached for higher updrafts, for which the fraction was higher for all mixing states. For Ext simulations, the maximum absolute overestimations were 304, 323 and 432 for the MP, MP and HP cases, respectively, while in Ext simulations for the same study cases they were of 637, 642 and 838 . The high aerosol number concentrations considered here, although characterizing polluted conditions like those that could be found in regional hazes in the Amazonia region, are still moderate in comparison with concentrations inside pyrocumulus.
It is important to note that, were the maximum supersaturations achieved in simulations for both mixing states to be the same, would be higher in the internal mixing case simulations and the CCN overestimations derived from assuming internal mixing would be larger. This difference in the achieved maximum supersaturations does not explain the much smaller impact of mixing state found for cloud parcel model results when compared to those obtained for equilibrium conditions and prescribed supersaturations, but is likely to contribute to it since, in the latter, the same maximum supersaturation is assumed in the estimation of for the different mixing states.
For Amazon smoke particles, these results indicate an overestimation in derived from assuming internal mixing overestimation for an externally mixed population that is below 10 % for all conditions.
Hygroscopicity
The behavior of the CCN activation, as hygroscopicity changed, was distinctly different for the different mixing states. When the population was assumed to be internally mixed, the mean average sensitivity to hygroscopicity, , was low for the case MP (0.20), and very low for MP (0.10) and HP (0.12) case studies. These estimations are in good agreement with those by and . For the externally mixed population, however, curves were far apart from a linear behavior and it was not possible to achieve linear fits. Obtained adjusted parameters were close to zero or negative and hence average sensitivities for externally mixed populations were not estimated.
Local sensitivities for the internal mixing state typically decreased as the hygroscopicity parameter increased, starting from median values of 0.35 for the MP case study and of 0.20 for the MP and HP case studies (Fig. ) until almost stabilizing at values close to 0.15, 0.05 and 0.10 for the same cases for values of within the medium and high hygroscopicity ranges. Notable exceptions were found within the updraft-limited regime for populations with high hygroscopicity where the impact of kinetic effects was high, as will be addressed later in Sect. 4.3. Except for cases within the updraft-limited regime, where kinetic limitations were significant, we found that the impact of the hygroscopicity parameter in was very low for internally mixed populations and within the MH or the HH ranges, while for values within the VLH range the impact was low to moderate, in agreement with results obtained by previous studies .
Box-and-whisker plots of the sensitivity of to the hygroscopicity parameter , showing spread of results for updraft velocities between 0.1 and 10 , for (a) MP, (b) MP and (c) HP case studies. Box bounds show the interquartile range, the mean value is indicated by a small square, and whiskers delimitate minimum and maximum values. Results for the internally mixed Int and externally mixed populations Ext and Ext are plotted in black, red and blue, respectively.
[Figure omitted. See PDF]
On the other hand, the local for the externally mixed populations presented mean values (over results for different updraft velocities) that increased with from very low or even negative to values between 0.3 and 0.45 for the highest values (Fig. ). This higher sensitivity of to in the external mixtures is also apparent in the step increase in obtained for the external mixing results for the larger average values (Fig. , bottom).
The increasing for external mixing cases can be illustrated through the consideration of the following example for the HP case and an updraft velocity . In the internally mixed population with , 62 % of the total was activated. If the internally mixed population has, instead, , the resulting fraction is 61 %. However, if the population with is instead externally mixed, the fraction of particles with that reached activation increased to 67 %, but, of the particles with (19 % of total population), only 22 % reached activation. Consequently, even when the MH particles predominated, the resulting ratio was 58 %, a more significant decrease from the case with than in the internally mixed population case.
Considering the results from the simulations and the little variability and low values of for internally mixed populations, variations in hygroscopicity within the MH and HR could be considered instead as secondary and neglected, especially if the difference in hygroscopicity is not large, since the level of sophistication within GCMs should be kept at a minimum whenever the accuracy of results is not compromised. When the hygroscopicity is within the LH and VLH, however, the overestimation in the activated fraction might also be substantial, as illustrated in Fig. for updraft velocities in the updraft- and aerosol-sensitive regime, for internally mixed populations. In the extreme case when was assumed for a population of , the mean overestimation of the CCN population for the MP, MP and HP was 54.3 3.7, 22.4 1.4 and 26.6 2,3 %, respectively. In comparison, if was presumed for aerosols with , the mean overestimations of obtained for the MP, MP and HP cases and the same range of updraft velocities were 15.5 1.6, 4.8 0.3 and 6.4 0.8 %, respectively.
Overestimation of (mean standard deviation over the updraft velocities in the updraft- and aerosol-sensitive regime) when is assumed, as a function of the population . Results correspond to MP (blue), MP (orange) and HP (grey) case studies for an internally mixed population.
[Figure omitted. See PDF]
A significant overestimation of can thus result from assuming a hygroscopicity in the MH range for the Amazon smoke aerosols. These results suggest that larger values of like those recommended for continental aerosol or biomass burning particles in other regions of the world are not adequate to describe the CCN activation behavior of Amazon smoke particles.
Kinetic limitations
Temporal series of the CCN activation with resolutions of 0.5 and 1 s near the time of maximum supersaturation for strong and low to moderate updrafts, respectively, were used to analyze the particle growth and activation evolution in time. Three separate effects in the evolution of were observed in the simulations for weak and sometimes even moderate updrafts that could be attributed to the effect of kinetic limitations: (1) a delay between the time when maximum supersaturation was reached and the time when the activated fraction is largest; (2) a decrease in the number of activated particles with cloud depth after the maximum activated fraction is reached; and, finally, (3) a overestimation of if assuming that equilibrium applies.
Supersaturation (left) and aerosol activated fraction (right) as a function of cloud height for an internally mixed population with (black), (red) and (blue), and . The cloud droplet concentration was estimated as either (dashed line), (solid line, open circles) or (solid line, close squares). The fraction of the population not strictly activated in is indicated (open downward-facing triangles). Plots on panels (a, b), (c, d) and (e, f) correspond to MP, MP and HP case studies, respectively.
[Figure omitted. See PDF]
The delay in activation was amplified with the increase in the particle . A relation to particle size and number concentration was also apparent, being the delay longest for the HP case, moderate in the MP case, and much shorter for the MP case, also for large values and weak updrafts. This is illustrated in Fig. for an internally mixed population and . Due to the delay in activation a significant fraction of particles was typically not activated at the time maximum supersaturation was reached. Within the updraft-limited regime, the delay in the activation was such that at the time of maximum supersaturation no particles are activated for internally mixed populations with above a certain threshold. For an updraft velocity of , this threshold was for the MP case and for the MP and HP cases. In the MP case, for an updraft velocity , already in the updraft- and aerosol-sensitive regime, the threshold was still . The maximum value of was also reached sometime after the maximum supersaturation is reached, and its value was slightly higher than the maximum of . However, the strong kinetic effects obtained for the larger values near the time of maximum supersaturation for were not as strong for . After the maximum is reached, however, differences between both estimations are below 1 % and at the end of the simulation both estimations are very similar. The fraction of particles not strictly activated in was important only near the time of maximum supersaturation, indicating that this assumption has no influence in results presented in previous sections, where cloud droplet concentrations were estimated at the end of the simulation. However, the differences near the time of maximum supersaturation would be larger if this fraction is disregarded.
For the externally mixed population Ext, although was significantly lower than for weak updrafts, in all the cases at least a fraction of particles was activated at the time of maximum supersaturation. For Ext and , however, populations with , or , also showed for both MP and HP cases at the time of maximum supersaturation. This is exemplified in Fig. for three values of the effective hygroscopicity parameter. Interestingly enough, particles from both hygroscopic groups failed to activate in these conditions. The value of maximum supersaturation was very low in these cases, and it is likely that particles in the more hygroscopic group condense the limited water vapor on their surfaces more readily, although not in great enough quantities as to activate themselves, but limiting the water vapor available to less hygroscopic particles even more and preventing their activation as well. Particles from both groups seem to grow rather slowly, and both groups appear to activate at the same time.
Supersaturation (left axis, grey) and aerosol activated fraction during the simulation (right axis) for the Ext population and the HP case study, for and (a), (b) and (c). The cloud droplet concentration was estimated as (dashed line), and for the population (black solid line, close squares) and hygroscopic groups with (red dashed line, open circles) and (blue dotted line, open upward-facing triangles).
[Figure omitted. See PDF]
As moderate and strong updrafts were considered, the delay between maximum supersaturation and maximum activation reduced until no longer observed at the temporal resolution of the time series. Within the updraft-limited regime, the mean overestimation of in comparison with over the range of , excluding those that led to , ranged from 10 to 100 % in internally mixed populations, and between 10 and 250 % in externally mixed ones (Fig. ), being larger for the higher values of . However, for all case studies and mixing states, the overestimation at the time of maximum supersaturation was typically below 12 % within the updraft- and aerosol-sensitive, and below 5 % within the aerosol-limited regime.
Overestimation of when the population is estimated assuming equilibrium at the time of maximum supersaturation, , compared with at the time of maximum supersaturation (blue) and at the end of the simulation (orange), for the range of updraft velocities. Values correspond to the MP (a–c), MP (d–f) and HP (g–i) case studies. The mixture of the aerosol population was either internal (left panels) or external as in Ext (middle panels) and Ext (right panels)
[Figure omitted. See PDF]
The overestimation of at the time of maximum supersaturation if assuming equilibrium applies can be explained by the evaporation mechanism. However, as the cloud depth increases, and in particular at the defined end of the simulation, the deactivation mechanism can be more relevant. Although was always lower at the end of the simulation than at its maximum, the difference was typically low, between 2 and 10 % for most updraft velocities and mixing states, as evidenced in the similar overestimations of both values by . Both evaporation and deactivation mechanisms were relevant for weak and even moderate updrafts, and a relation with particle size and number concentration was apparent, as previously reported by for ammonium sulfate particles. Our results are also consistent with the reduction in the droplet concentrations of up to 35 % due to kinetic limitations found by for updrafts of 0.1 and aerosol data corresponding to the dry season in Amazonia.
In our results, the effects of kinetic limitations were strong when a significant fraction of particles with hygroscopicity in the MH or LH range was present. However, for particles with low and very low hygroscopicities like the Amazon smoke particles, kinetic limitations were less important, even if large aerosol loads were present.
A relation between the timescale of solubility and the CCN activation behavior of aerosols is known , and several studies have analyzed kinetic limitations by comparing the aerosol particles' growth and that of a calibration aerosol with a high solubility and the same critical supersaturation, with mixed conclusions regarding the importance of this process to CCN activation . However, at the low supersaturations reached as a result of the weak updraft velocity and the large aerosol loads considered, the kinetic limitations discussed in this study derive more likely from the differences in water uptake and critical supersaturation due to the particle hygroscopicity.
Conclusions
The available data on smoke particles in the Amazon region (Sect. 3) suggest that this aerosol population has a rather consistent size and that external mixing of two particle groups having very low and low hygroscopicity, respectively, is typical for this aerosol population. We conducted cloud model simulations using three hypothetical case studies and a variety of hygroscopicities and mixing states that resembled typical conditions found in the literature for smoke aerosols in the Amazon in moderate to highly polluted conditions. Simulations were conducted for these three case studies to estimate the effect of different values of hygroscopicity and mixing state, including those conditions that resemble observed data for smoke particles (Ext). The impact of kinetic limitations was assessed.
The impact in the surface tension due to the organic material present in smoke aerosols is likely to be relevant , but was not included in this work due to the complex organic composition of these particles that lead to difficulties for its modeling. We consider this a limitation of our results that should be addressed in future works.
A low sensitivity of the cloud droplet number concentration to the population effective hygroscopicity parameter was found for medium and large hygroscopicity when the population was internally mixed. However, for particles with hygroscopicity in the lower range of , the effective hygroscopicity of smoke particles for the Amazon appears to stand in the VLH and LH ranges, where the sensitivity to this parameter was found to be moderate. Therefore, could be overestimated significantly if larger values of hygroscopicity, like those suggested for biomass burning particles elsewhere, were to be used for Amazonia smoke particles.
Hygroscopic mixing state in the conducted cloud model simulations led to differences lower than those obtained in previous studies that addressed mixing state for equilibrium conditions and prescribed supersaturations. In particular, the overestimation of was low for populations similar in hygroscopicity to the Amazon smoke aerosols (Ext in the simulations), but slightly higher when the external mixing was between groups with VLH and MH (Ext).
The parameter posed a much larger impact on the CCN activation within the MH range for externally mixed populations than for internally mixed ones, even for low fractions of VLH aerosols. When is estimated assuming internal mixing, and in particular when particles of VLH are present, it is important to take into account that the typically low sensitivity to hygroscopicity of internally mixed populations does not apply and even relatively small variabilities in could affect the CCN activation behavior of the population. Consequently, assuming internal mixing of particles with very low and low-hygroscopicity particles with moderate or large hygroscopicity should be avoided.
Finally, kinetic limitations were found to be much lower for particles within VLH and LH hygroscopic groups, and therefore its impact on the CCN behavior of Amazon smoke particles is expected to be limited, in spite of the presence of large aerosol loads.
The inclusion of mixing state, adequate hygroscopicity values and the consideration of kinetic limitations into global and regional circulation model are all possible, although in many cases at a computational cost. The choice of using two separate aerosol populations to account for the externally mixing character of the biomass burning population will increase the computational burden of the model, and the modeler might choose instead to consider biomass burning aerosols as only one population internally mixed and externally mixed with other aerosol populations, given that the overestimation derived from this choice is not significant. Global models or regional models over a large domain should specify, if possible, the aerosol hygroscopicity for different regions, in particular when values in the very low or low range of hygroscopicity are to be considered. Also, for Amazonia smoke aerosols, the choice of a parameterization that accounts for kinetic limitations, typically more demanding in terms of computational resources, might not improve results significantly over a parameterization that does not account for their impact.
Data availability
The cloud model used can be made available upon request, as well as the maximum supersaturations and activated fractions obtained for each condition. Full solutions for the ODE system are also available but in a machine-dependent format. Please contact the correspondence author.
Nomenclature of frequently used symbols
CCN | Cloud condensation nuclei |
Particle cut diameter for activation (dry) | |
Number fraction of hygroscopic group (hg) | |
Aerosol number concentration | |
Cloud droplet number concentration | |
estimated assuming equilibrium conditions | |
estimated without assuming | |
equilibrium conditions | |
Supersaturation | |
Cloud maximum supersaturation | |
Sensitivity of to the parameter | |
Time | |
Temperature | |
Cloud parcel updraft velocity | |
Specific hygroscopicity parameter | |
by | |
Population effective specific hygroscopicity | |
parameter |
Simplified Köhler equation and estimation of the cut diameter for CCN activation
For an aerosol particle with dry diameter formed by a soluble fraction and an insoluble core, the Köhler equation can be approximated by the expression where is the supersaturation, is the particle wet diameter, and terms and are parameters in the curvature and solute terms of the Köhler equation. In this work, was assumed to be identical to the parameter for all values of and .
It can be shown that the particle cut wet diameter for activation can be estimated as where the parameters and are estimated as and
Finally, the corresponding dry diameter of the smallest activated particle, , can be calculated as
The Supplement related to this article is available online at
The authors declare that they have no conflict of interest.
Acknowledgements
The authors thank three anonymous referees for their valuable suggestions and comments that contributed significantly to the improvement of the present paper. This work was supported by the São Paulo Research Foundation (FAPESP), through the projects 2012/13575-9, DR 2012/09934-3, BEPE 2013/02101-9 and BPE 2014/01564-8. Edited by: H. Coe Reviewed by: three anonymous referees
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
© 2017. This work is published under http://creativecommons.org/licenses/by/3.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.
Abstract
Smoke aerosols prevail throughout Amazonia because of widespread biomass burning during the dry season, and external mixing, low variability in the particle size distribution and low particle hygroscopicity are typical. There can be profound effects on cloud properties. This study uses an adiabatic cloud model to simulate the activation of smoke particles as cloud condensation nuclei (CCN) for three hypothetical case studies, chosen as to resemble biomass burning aerosol observations in Amazonia. The relative importance of variability in hygroscopicity, mixing state, and activation kinetics for the activated fraction and maximum supersaturation is assessed. For a population with
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Details


1 Center for Weather Forecasting and Climate Research, INPE, Cachoeira Paulista, SP, Brazil
2 Center for Weather Forecasting and Climate Research, INPE, Cachoeira Paulista, SP, Brazil; now at: Universities Space Research Association/Goddard Earth Sciences Technology and Research (USRA/GESTAR) at Global Modeling and Assimilation Office, NASA Goddard Space Flight Center, Greenbelt, MD, USA
3 School of Engineering and Applied Science, Harvard University, Cambridge, MA, USA