Introduction
Atmospheric aerosol particles are known to modify the microphysical properties of clouds, such as their albedo, lifetime and precipitation patterns (Boucher et al., 2013). Due to the importance of clouds in the weather and climate systems, these aerosol-induced changes, known as the indirect effects of aerosol on climate, are a subject of rigorous research. The quantification of the radiative forcing associated with the interactions of atmospheric aerosol with clouds remains one of the biggest challenges in the current understanding of climate change (Boucher et al., 2013). These challenges are associated with the production of the aerosol particles that are able to activate into cloud droplets, known as cloud condensation nuclei (CCN) (e.g. Laaksonen et al., 2005; Andreae and Rosenfeld, 2008; Kuang et al., 2009; Kerminen et al., 2012), their actual activation into cloud drops (e.g. Kulmala et al., 1996; Dusek et al., 2006; McFiggans et al., 2006; Paramonov et al., 2013; Hammer et al., 2014), the formation of clouds (e.g. Twomey, 1959; Mason and Chien, 1962; Vaillancourt et al., 2002), time evolution of cloud microphysical and other properties (e.g. Rosenfeld et al., 2014) and the interaction of clouds with the solar and terrestrial radiation (e.g. Boucher and Lohmann, 1995; Ramanathan et al., 2001; Chen et al., 2014). A better understanding is needed with respect to each of these steps in order to improve the performance of the current global climate models (GCMs) and to increase the accuracy of the future climate predictions.
Several aerosol properties are of special interest when looking at the interaction of atmospheric aerosol particles with warm clouds. The current article focuses on the number, size and hygroscopicity of the atmospheric aerosol particles with regard to how these parameters affect the potential of particles to act as CCN. One such property of interest is the CCN number concentration . Depending on the location, can vary by several orders of magnitude, and it directly depends on the aerosol properties and the ambient water vapour supersaturation ratio in the atmosphere. Köhler theory dictates that the minimum size at which particles activate into cloud drops decreases with increasing (Köhler, 1936); consequently increases monotonically with for a given aerosol population. The exact response of to an increasing depends on the total aerosol number concentration , aerosol size distribution and particle hygroscopicity. Besides the relevant references found throughout the paper, discussion about concentrations in various environments can be found in, e.g. Pandis et al. (1994), Covert et al. (1998), Snider and Brenguier (2000), Chang et al. (2007), Andreae and Rosenfeld (2008), Andreae (2009) and Wang et al. (2010). At any given , another property of interest is the critical dry diameter of CCN activation , defined as the smallest diameter at which particles activate into cloud drops. For internally mixed polydisperse aerosol particles, this diameter indicates that in the presence of a sufficient amount of water vapour all particles above this size activate into cloud drops, and all particles below this size do not. However, atmospheric aerosol is frequently externally mixed, with particles of different sizes exhibiting different chemical composition, and, therefore, in practice, is usually estimated as the diameter at which 50 % of the particles activate and grow into cloud drops at any given . can be directly calculated from size-segregated cloud condensation nuclei counter (CCNC) measurements (Rose et al., 2008) or estimated from the size distribution data coupled with (Hitzenberger et al., 2003; Furutani et al., 2008). The effect of hygroscopicity on the activation of CCN into cloud drops has also been studied extensively, and several simplified theoretical models have been suggested to link particle composition with critical supersaturation , i.e. the minimum required for the particles of a certain size to activate into cloud drops (e.g. Svenningsson et al., 1992; Rissler et al., 2005; Khvorostyanov and Curry, 2007; Wex et al., 2007). One such approach is the hygroscopicity parameter , also known as “kappa”, a unitless number describing the cloud condensation nucleus activity (Petters and Kreidenweis, 2007). The value of typically varies between zero and just above unity, with values close to zero indicating a non-hygroscopic aerosol, i.e. with low affinity for water (e.g. freshly emitted black carbon; e.g. Hudson et al., 1991; Weingartner et al., 1997; Wittbom et al., 2014) and values close to unity indicating an aerosol with high hygroscopicity, i.e. high affinity for water (e.g. sea salt particles; e.g. Good et al., 2010). Since its introduction, the parameter has been used in CCN studies quite extensively (e.g. Carrico et al., 2008; Kammermann et al., 2010a; Levin et al., 2014).
This article summarises the measurements performed by CCNCs within the framework of the European Integrated project on Aerosol Cloud Climate and Air Quality interactions (EUCAARI). One of the EUCAARI project aims was to compile a comprehensive database of in situ measured aerosol, CCN and hygroscopic properties in order to increase the knowledge about aerosol–cloud–climate interactions and to combine the relevant existing measurement infrastructure (Kulmala et al., 2011). Besides CCNCs already deployed at the existing European long-term measurement stations, several intensive field campaigns using the CCNC were carried out as part of EUCAARI as well. The main objective of this work is to present a comprehensive overview and intercomparison of CCNC measurements and to provide an insight into the cloud droplet activation and aerosol hygroscopic properties in different environments. More specifically, the aims are to (i) get new insight into CCN number concentrations and activated fractions around the world and their dependence on the water vapour supersaturation ratio, (ii) provide new information about the dependence of aerosol hygroscopicity on particle size, and (iii) reveal seasonal and diurnal variation of CCN activation and hygroscopic properties. While undeniably important, the effect of size distribution on and the size-resolved activated fraction (e.g. Dusek et al., 2006; Quinn et al., 2008; Morales Betancourt and Nenes, 2014) is not investigated herein, and an overview of the existing EUCAARI aerosol size distribution data can be found in Asmi et al. (2011) and Beddows et al. (2014).
Methodology
Instrumentation
A CCNC is a type of instrument frequently used for studying the cloud droplet activation potential of aerosol particles. In its simplest set-up, a CCNC consists of a saturator unit and an optical particle counter (OPC) frequently running in parallel with a condensation particle counter (CPC). For all measurements presented herein, the CCNC used was a commercially available instrument produced by Droplet Measurement Technologies, Inc. (DMT-CCNC), the basic principles of operation of which are described below.
Upon entering the measurement set-up, the aerosol flow is split into two sample flows, with the first flow leading to a CPC to determine the total particle number concentration, hereafter referred to as . The second flow feeds the aerosol into the saturator unit of the CCNC, inside of which the conditions of supersaturation with respect to water vapour down the centre of the column are established. Aerosol, flowing under laminar flow conditions, is subjected to these supersaturation conditions, during which particles with a critical supersaturation smaller than will grow by the condensation of water vapour and remain in stable equilibrium, i.e. activate as CCN. The residence time inside the saturator column ( ) allows for the activated particles to grow to sizes larger than 1 in diameter; these particles are then counted by the OPC providing the number concentration of activated aerosol particles, a quantity hereafter referred to as . The described set-up is characteristic of polydisperse measurements; an inclusion of a drier, a neutraliser and a differential mobility analyzer (DMA; Knutson and Whitby, 1975) prior to the splitting of the flow into two parallel lines allows for the selection of a particular particle size, i.e. quasi-monodisperse measurements. Such measurements can be performed either by varying the particle size at a constant (-scan) or by varying at a constant particle size (-scan). Such a set-up, while more complex, provides activation spectra and allows for a direct calculation of the critical dry diameter of droplet activation (in case of the -scan) or the critical supersaturation (in case of the -scan). Typically, a CCNC operates at several different levels of , most commonly ranging between 0.1 and 1.0 %; the deviations from the nominal assigned values can be monitored and corrected by applying a standardised calibration procedure, as described in Sect. 2.3. A more detailed description of the general operating procedures of the CCNC can be found in Roberts and Nenes (2005); exact details of the measurement set-up at each of the locations described in the next section can be found in the respective published literature referenced throughout the text.
A world map showing the locations of CCNC measurements performed during EUCAARI and presented in this study.
[Figure omitted. See PDF]
Names, locations and descriptions of all measurement sites presented in the analysis.
| Name of station or campaign | Location | Geographic coordinates | Elevation | Site description |
|---|---|---|---|---|
| ( a.m.s.l.) | ||||
| Hyytiälä | southern Finland | 6151 N, 2417 E | 181 | rural background |
| Vavihill | southern Sweden | 5601 N, 1309 E | 172 | rural background |
| Jungfraujoch/CLACE-6 | Swiss Alps | 4633 N, 0759 E | 3580 | free troposphere |
| Mace Head | west coast of Ireland | 5319 N, 0954 W | 0 | coastal background |
| Pallas | northern Finland | 6758 N, 2407 E | 560 | remote background |
| Finokalia | northern Crete | 3520 N, 2540 E | 250 | remote coastal |
| Cabauw | central Netherlands | 5158 N, 0456 E | rural background | |
| K-puszta | central Hungary | 4658 N, 1933 E | 125 | rural |
| Chilbolton | southern United Kingdom | 5109 N, 0126 W | 78 | continental background |
| COPS | south-west Germany | 4836 N, 0812 E | 1156 | continental background |
| RHaMBLe | tropical North Atlantic | N, 20 W | 0 | remote marine |
| PRIDE-PRD2006 | southeastern China | 2333 N, 11304 E | 28 | rural background |
| AMAZE-08 | northern Brazil | 0236 S, 6013 W | 108 | remote background |
| CAREBeijing-2006 | northern China | 3931 N, 11618 E | 30 | suburban |
Measurement sites
Data from a total of 14 EUCAARI locations have been provided for this analysis, including both long-term measurement stations and short-term campaigns (Fig. 1). As seen in the figure, data sets came from a wide variety of locations representing various environments, including marine and continental, urban and background, at altitudes ranging from the ground level to the free troposphere. The location and description of each measurement site are given in Table 1. All measurements presented herein were performed within the EUCAARI framework.
Hyytiälä Forestry Field Station in southern Finland is the location of the Station for Measuring Ecosystem–Atmosphere Relations (SMEAR II), operated by the University of Helsinki. Located on a flat terrain and surrounded by the boreal coniferous forest, mainly Scots pine, the station is well representative of the boreal environment (Hari and Kulmala, 2005). It is a rural background site, with the nearest city of Tampere (population 220 000) located 50 to the south-west. Air masses at the site can be of both Arctic and European origin; however, aerosol particle number concentrations at this site are typically low (Sogacheva et al., 2005).
Vavihill in southern Sweden is a continental background site surrounded by grasslands and deciduous forest and operated by Lund University. The site is located 60–70 NNE of the Malmö and Copenhagen urban area (population ); however, it is considered to not be affected by the local anthropogenic sources (Tunved et al., 2003). Due to its location, the site is often used for monitoring the transport of pollution from continental Europe into the Nordic region (Tunved et al., 2003).
The Jungfraujoch is a high Alpine station in the Bernese Alps in Switzerland, where the aerosol measurements are performed by the Paul Scherrer Institute (PSI). Being located high in the mountains (3580 a.s.l.), the station is far from local sources of pollution and is, in fact, in the free troposphere most of the time; hence, it is considered a continental background site and aerosol concentrations are very low (Collaud Coen et al., 2011). However, particularly during the summer months, the Jungfraujoch site is frequently influenced by the injections of more polluted air from the planetary boundary layer, driven by thermal convection (Jurányi et al., 2010, 2011; Kammermann et al., 2010a). The station is frequently inside clouds allowing for direct measurements of aerosol–cloud interactions.
Mace Head is a coastal marine site located on the west coast of Ireland and operated by the National University of Ireland, Galway. The distance to the nearest urban settlement of Galway City (88 , population 65 000) renders Mace Head a clean background site; being on the coast, the station is directly exposed to the North Atlantic Ocean. Occasionally the station is subject to more polluted air masses originating from continental Europe and the United Kingdom (O'Dowd et al., 2014).
Pallas is a remote continental site in northern Finland located in the northernmost boreal forest zone in Europe; it is run by the Finnish Meteorological Institute (FMI). The station is situated on top of a treeless hill and, due to the frequent presence of clouds, is suitable for in situ measurements of aerosol–cloud interactions. The Pallas station is subject to both clean Arctic air masses, as well as to more polluted European air masses; regardless, absolute particle number concentrations are typically low (Hatakka et al., 2003).
Finokalia station is a remote coastal site located on the island of Crete and operated by the University of Crete. The station is located on top of a hill, and most frequently air masses arrive in Finokalia over the Mediterranean Sea (Stock et al., 2011). The station is representative of background conditions as there are no local sources of pollution present; the largest nearby urban centre of Heraklion (population 175 000) is 50 to the west.
The Cabauw Experimental Site for Atmospheric Research (CESAR) is located in the central Netherlands, 44 from the North Sea. The station is in a rural area; however, the big cities of Utrecht and Rotterdam are nearby; the station is subject to both continental and maritime conditions (Mensah et al., 2012). The station is operated by the Royal Netherlands Meteorological Institute (KNMI).
Periods of available data for all locations and campaigns.
[Figure omitted. See PDF]
Summary of available data for each measurement location. is the CCN number concentration, is the total number concentration, is the activated fraction, is the critical dry diameter and is the hygroscopicity parameter. The “set-up” column indicates whether the CCNC was operating in polydisperse or monodisperse mode. and have been calculated from polydisperse data using the differential/scanning mobility particle sizer (DMPS/SMPS) data.
| Name of station or campaign | Set-up | Parameters | levels | Time resolution | Reference |
|---|---|---|---|---|---|
| Hyytiälä | poly & mono | , , , , | 0.0859, 0.1, 0.2, 0.216, 0.3, 0.4, 0.478, 0.5, 0.6, 0.74, 1.0, 1.26 % | original | Paramonov et al. (2013) |
| Vavihill | poly | , , , , | 0.1, 0.2, 0.4, 0.7, 1.0 % | original | Fors et al. (2011) |
| Jungfraujoch | poly | , , , , | 0.12, 0.24, 0.35, 0.47, 0.59, 0.71, 0.83, 0.95, 1.07, 1.18 % | original | Jurányi et al. (2010, 2011) |
| Mace Head | poly | , , | 0.25, 0.5, 0.75 % | averaged | Ovadnevaite et al. (2011) |
| Pallas A | poly | , , , , | 0.2, 0.4, 0.6, 0.8, 1.0 % | original | Jaatinen et al. (2014) |
| Pallas B | poly & mono | , , , , | 0.47, 0.72, 0.97, 1.22 % | averaged (poly), original (mono) | n/a |
| Pallas C | poly & mono | , , , , | 0.1, 0.15, 0.2, 0.6, 1.0 % | averaged (poly), original (mono) | Brus et al. (2013) |
| Finokalia A | mono | , , | 0.21, 0.38, 0.52, 0.66, 0.73 % | averaged | Bougiatioti et al. (2009) |
| Finokalia B | poly | , , | 0.21, 0.38, 0.52, 0.66, 0.73 % | averaged | Bougiatioti et al. (2009) |
| Cabauw | poly | varies between 0.1 and 1.0 % | original | Bègue (2012) | |
| K-puszta | mono | , , | 0.03, 0.04, 0.10, 0.17, 0.20, 0.25, 0.44, 0.62, 0.67 % | averaged | n/a |
| Chilbolton | mono | , , , | 0.11, 0.30, 0.56, 0.94 % | averaged | Whitehead et al. (2014) |
| COPS | poly & mono | , , , | 0.11, 0.17, 0.24, 0.28, 0.32, 0.35, 0.43, 0.50, 0.65, 0.80 % | averaged | Irwin et al. (2010), Jones et al. (2011), Whitehead et al. (2014) |
| RHaMBLe | poly & mono | , , , | 0.09, 0.16, 0.29, 0.47, 0.74 % | averaged | Good et al. (2010), Whitehead et al. (2014) |
| PRIDE-PRD2006 | mono | , , , , | 0.068, 0.27, 0.47, 0.67, 0.87, 1.27 % | original | Rose et al. (2010, 2011) |
| AMAZE-08 | mono | , , , , | 0.095, 0.19, 0.28, 0.46, 0.82 % | original | Gunthe et al. (2009) |
| CAREBeijing-2006 | mono | , , , , | 0.066, 0.26, 0.46, 0.66, 0.86 % | original | Gunthe et al. (2011) |
| CLACE-6 | mono | , , , , | 0.079, 0.17, 0.27, 0.46, 0.66 % | original | Rose et al. (2013) |
Average concentrations () at all studied locations. All concentrations were recalculated to correspond to the levels suggested by the ACTRIS network: 0.1, 0.2, 0.3, 0.5 and 1.0 %. The four long-term data sets are shown at the top of the table.
| Name of station or campaign | % | % | % | % | % |
|---|---|---|---|---|---|
| Vavihill | 362 | 745 | 952 | 1285 | 1795 |
| Hyytiälä | 274 | 407 | 526 | 824 | 1128 |
| Mace Head | 472 | 526 | 581 | 691 | 1007 |
| Jungfraujoch | 135 | 249 | 341 | 444 | 599 |
| PRIDE-PRD2006 | 1888 | 4594 | 6956 | 9760 | 13 855 |
| CAREBeijing-2006 | 2547 | 4751 | 6510 | 8460 | 10 711 |
| Cabauw | 435 | 1607 | 2208 | 3235 | 6439 |
| Finokalia B | 903 | 1167 | 1431 | 1793 | 2354 |
| Finokalia A | 946 | 1257 | 1567 | 1882 | 2109 |
| COPS | 3 | 210 | 364 | 710 | – |
| RHaMBLe | 300 | 535 | 717 | 922 | 1153 |
| K-puszta | 146 | 349 | 512 | 727 | 834 |
| Chilbolton | 145 | 210 | 274 | 384 | 506 |
| CLACE-6 | 66 | 126 | 156 | 205 | 303 |
| Pallas B | – | – | 149 | 176 | 247 |
| AMAZE-08 | 37 | 85 | 112 | 136 | 205 |
| Pallas C | 14 | 38 | 50 | 74 | 141 |
| Pallas A | 7 | 19 | 31 | 50 | 98 |
The University of Manchester conducted four short-term measurement campaigns utilising a CCNC: K-puszta, Chilbolton, COPS and RHaMBLe. K-puszta is a rural site surrounded by deciduous–coniferous forest located on the Great Hungarian Plain in central Hungary 80 SE of Budapest. The site has no local anthropogenic pollution sources (Ion et al., 2005). Chilbolton is also a rural site, located in southern United Kingdom, 100 WSW of London. The site is most frequently influenced by the marine air masses; a potential local source of anthropogenic pollution is the seasonal agricultural spraying (Campanelli et al., 2012). The Convective and Orographically-induced Precipitation Study (COPS) campaign took place at the top of the Hornisgrinde Mountain in the Black Forest region of south-west Germany. While this site is primarily surrounded by the coniferous forest, the close proximity to the Rhine Valley exposes the site to some anthropogenic pollution. Due to its elevation, the site is occasionally in the free troposphere (Jones et al., 2011). The Reactive Halogens in the Marine Boundary Layer (RHaMBLe) Discovery Cruise D319 campaign was a cruise conducted in the tropical North Atlantic between Portugal and Cabo Verde. The operational area can be described as a remote marine environment with few, if any, sources of anthropogenic pollution. Air masses can originate from both the ocean and from the African mainland (Good et al., 2010).
The Max Planck Institute for Chemistry (MPIC) also conducted four CCNC measurement campaigns within the EUCAARI framework: PRIDE-PRD2006, AMAZE-08, CAREBeijing-2006 and CLACE-6, with the last one having taken place at the previously described Jungfraujoch station. The PRIDE-PRD2006 campaign took place in southeastern China, in a small village NW of Guangzhou, in the vicinity of a densely populated urban centre. The wind direction during the campaign rendered the site a rural receptor of the regional pollution originating from the Guangzhou urban cluster (Rose et al., 2010). The AMAZE-08 campaign took place at a remote site in an Amazonian rainforest, 60 NNW of Manaus, Brazil. During the campaign, the site experienced air masses characteristic of clean tropical rainforest conditions as well as air masses influenced by long-range transport of pollution (Gunthe et al., 2009; Martin et al., 2010). The CAREBeijing-2006 campaign was conducted at a suburban site in northern China, on the grounds of Huang Pu University in Yufa, south of Beijing. The site is subject to air masses originating both in the south and in the north; however, being located on the outskirts of a large urban centre, particle concentrations are generally high (Garland et al., 2009).
Data
The measurement period for each location and a brief summary of available CCNC data are presented in Fig. 2 and Table 2, respectively. Available data range from mid-2006 to the end of 2012; the four long-term data sets all exceed one year in duration. As originally requested by the authors from the EUCAARI partners, some of the data were submitted in the NASA-Ames format with daily and monthly/campaign averages. Other data sets were submitted in the original time resolution and have been compiled accordingly for this overview study.
For the quality assurance of the CCNC data, data providers were requested to recalculate all values to correspond to the standard temperature and pressure and to utilise a consistent procedure for the CCNC calibration. Calibrations were asked to be performed as outlined in Rose et al. (2008) using nebulised, dried, charge-equilibrated and size-selected ammonium sulphate or sodium chloride aerosol particles. To predict for instrument calibration, water activity was asked to be parameterised according to either the AIM-based model (Rose et al., 2008) or the ADDEM model (Topping, 2005); both of these models can be considered as accurate sources of water activity data, and the discussion about their associated uncertainties can be found in the corresponding references. As none of the participating data providers noted a deviation from the calibration procedure, it is assumed that the data were treated accordingly. However, deviations from the described procedure and from the target levels may be possible and can potentially affect some of the conclusions presented in this paper. Uncertainties associated with deviations from the mentioned calibration procedure and parameterisation are discussed in great detail in Rose et al. (2008) and Topping (2005).
Average cumulative for all available locations shown as a percentage of the measured at the of 1.0 % (above each bar). Colours indicate the supersaturation bins.
[Figure omitted. See PDF]
For some of the polydisperse data sets, where available, differential/scanning mobility particle sizer (DMPS/SMPS; Wang and Flagan, 1989; Wiedensohler et al., 2012) data were used in conjunction with the CCNC to derive the critical dry diameter . The procedure was carried out by comparing to the DMPS/SMPS-derived number size distributions; these were integrated from the largest size bin until the cumulative concentration was equal to . was then calculated by interpolating between the two adjacent size bins (Furutani et al., 2008). Following the calculation of , the hygroscopicity parameter was determined using the effective hygroscopicity parameter (EH1) Köhler model (Eq. 1) assuming the surface tension of pure water (Petters and Kreidenweis, 2007; Rose et al., 2008). Due to the surface tension of actual cloud droplets being lower than that of pure water droplets (Facchini et al., 2000), this assumption, although commonly used, typically leads to an overestimation of the (Kammermann et al., 2010b). where is water vapour saturation ratio, is the droplet diameter, is the dry particle diameter, which, as per Rose et al. (2008), can be substituted with , is the hygroscopicity parameter, is the surface tension of condensing solution (assumed to be pure water), is the molar mass of water, is the universal gas constant, is the absolute temperature and is the density of pure water.
For certain sites, total number concentrations of particles larger than 50 or 100 in diameter ( or were calculated from the corresponding DMPS or SMPS data.
In order to compare the results from different stations, several interpolation/extrapolation techniques were used. All concentrations were averaged for each site for each level and then recalculated to correspond to the target levels suggested by the Aerosols, Clouds and Trace gases Research InfraStructure (ACTRIS) Network: 0.1, 0.2, 0.3, 0.5 and 1.0 %. Recalculation to the nearest target supersaturation was accomplished by a simple linear interpolation/extrapolation of as a function of using the two adjacent/nearest points. For the Jungfraujoch data, at of 0.12 and 0.95 % was recalculated to the corresponding at the target of 0.1 and 1.0 %, respectively, assuming a size-independent .
Results and discussion
CCN concentrations
Table 3 presents CCN number concentrations at all 18 measurements locations and campaigns for five levels mentioned in the previous section. First and foremost, since CCN are simply a fraction of the total aerosol population with their concentration depending on , values at of 1.0 % follow a similar pattern known from total particle number concentrations. The lowest values, thus, originate in remote and clean locations, such as Pallas, the Amazonian rainforest (AMAZE-08), Jungfraujoch and Chilbolton. The highest values are found in more polluted locations – CAREBeijing-2006 and PRIDE-PRD2006, both in China. At lower levels, other effects, such as those of size distribution and hygroscopicity, become more pronounced. When examining at of 0.1 %, the highest values are still found in China; similar to at of 1.0 %, the lowest values are found in Pallas, the Amazonian rainforest (AMAZE-08), Jungfraujoch and also in south-west Germany (COPS).
Average activated fraction as a function of supersaturation for all available data sets. Symbols represent arithmetic mean values of calculated from all available data for each station for each level. Lines represent the linear fits in the form . Also shown is the overall fit based on most of the data points (*Finokalia, COPS, Jungfraujoch and Pallas A, B and C data sets excluded). The shading of the overall fit represents the prediction bounds of the fit with a confidence level of 95 %. Slope, intercept and correlation coefficient values of the linear fits can be found in Table 4.
[Figure omitted. See PDF]
In order to examine the CCN activation spectra in more detail, Fig. 3 presents cumulative concentrations shown as a percentage of the measured at the highest of 1.0 %. One group of locations that can be pointed out in the figure is representative of the marine environment: Finokalia, Mace Head and the RHaMBLe campaign. At these marine locations the presence of large and hygroscopic sea salt particles is expected, and a large fraction of particles already activates at the lowest , i.e. of the total measured at the highest , about a third activates already at the lowest . In the case of Mace Head, the observed behaviour is due to the presence of sea salt particles and a peculiar organic composition of the marine aerosol (Ovadnevaite et al., 2011). Additionally, both Finokalia and Mace Head have a large fraction of the long-range transported and aged aerosol (Bougiatioti et al., 2009; Ovadnevaite et al., 2011), which has been shown to increase particle hygroscopicity (Perry et al., 2004; Furutani et al., 2008). Chilbolton, being a continental background site representative of the regional aerosol properties, also belongs to this group; however, the concentrations at this location may be underestimated due to the aerosol not being dried prior to entering the CCNC (Whitehead et al., 2014).
Another group of locations with a different CCN activation pattern is represented by Pallas and Cabauw – at these locations very few particles activate at the lowest , and the increases drastically when changes from 0.5 to 1.0 %. This may indicate that the aerosol is dominated by the Aitken mode particles and, to a lesser extent, that the aerosol may be of low hygroscopicity. A high concentration of Aitken mode particles in the autumn and low aerosol hygroscopicity in Pallas have been previously reported by Tunved et al. (2003) and Komppula et al. (2006), respectively. The two measurement locations discussed here are interesting with regard to the ratio of presumed cloud droplet number concentration (CDNC) to the total aerosol particle number concentration. It has been reported that, although under the clean and convective conditions ambient may reach as high as 1.0 %, in the polluted boundary layer usually remains below 0.3 % (Ditas et al., 2012; Hammer et al., 2014; Hudson and Noble, 2014). If one assumes this value, a comparatively small fraction of aerosol in northern Finland and central Netherlands would potentially activate into cloud droplets if exposed to this . This has direct implications for the cloud formation and, thus, local climate at these locations.
Activated fraction
Another variable describing CCN activation properties of an aerosol population that was examined for the majority of locations is the activated fraction calculated as a ratio of to (Fig. 4). Each activation curve in Fig. 4 is based on the arithmetic mean values of calculated from all available data for each station for each level. Included in the figure is the overall fit shown with prediction bounds (95 % confidence level) based on most of the activation curves, except the outlying ones of Finokalia, COPS, Jungfraujoch and Pallas A, B and C. As can be seen in the figure from the similar shape and placement of the activation curves and in Table 4 from the similar slope and intercept values, for many locations there is no discernible difference in how responds to changing on an annual basis; this is further signified by the prediction bounds of the overall fit. Therefore, the average total number concentration alone is sufficient in order to roughly estimate the annual mean at any given , for example, using the overall fit parameters presented in Table 4. The appropriateness of the overall fit for estimating based on alone was investigated for the whole Hyytiälä data set, by comparing the measured by the CCNC with the calculated using the and the overall fit presented in Table 4. Such a comparison revealed that for Hyytiälä the overall fit leads to an annual median overestimation of of 49, 41, 33, 17 and 2 % for the levels of 0.1, 0.2, 0.3, 0.5 and 1.0 %, respectively.
Parameters of the linear fit , for all locations depicted in Fig. 4. is the slope, is the intercept and is the correlation coefficient of the simple linear regression. The overall linear fit is based on most of the activation curves depicted in Fig. 4, except Finokalia, COPS, Jungfraujoch and Pallas A, B and C.
| Name of station or campaign | |||
|---|---|---|---|
| Hyytiälä | 0.21 | 0.62 | 0.99 |
| Vavihill | 0.21 | 0.64 | 1.00 |
| Jungfraujoch | 0.17 | 0.48 | 1.00 |
| Mace Head | 0.23 | 0.79 | 0.98 |
| Finokalia | 0.29 | 0.86 | 0.99 |
| Pallas A | 0.08 | 0.19 | 0.99 |
| Pallas B | 0.15 | 0.49 | 0.98 |
| Pallas C | 0.13 | 0.35 | 0.98 |
| COPS | 0.31 | 0.92 | 0.97 |
| RHaMBLe | 0.21 | 0.70 | 1.00 |
| Pride-PRD2006 | 0.26 | 0.74 | 0.99 |
| AMAZE-08 | 0.23 | 0.70 | 0.99 |
| CARE-Beijing2006 | 0.22 | 0.74 | 1.00 |
| CLACE-6 | 0.22 | 0.69 | 1.00 |
| Overall | 0.22 | 0.69 | 0.96 |
For levels below 0.3 %, the variability of the overall fit, as shown by the prediction bounds, leads to the uncertainty of the predicted of up to an average of %. This uncertainty decreases exponentially for levels above 0.3 %. A global modelling study conducted by Moore et al. (2013) reported that CDNC over the continental regions is fairly insensitive to , where a 4–71 % uncertainty in leads to a 1–23 % uncertainty in CDNC. Since the overwhelming majority of measurements analysed in this paper were conducted on land, and the overall fit results in an uncertainty of the predicted annual mean of up to %, for many sites the use of the overall fit would yield a deviation of the predicted average CDNC of approximately less than 10 %. CDNC, however, is more sensitive to in cleaner regions with low total particle number concentrations, such as the Alaskan Arctic and remote oceans (Moore et al., 2013). In such areas the use of the overall fit may not be appropriate.
Four locations stand out in Fig. 4, which were not included in the overall fit. is visibly higher in Finokalia and during the COPS campaign than in other locations, with approximately 60 % of the total aerosol population at both locations activating into cloud drops at the of %. Reasons for the observed behaviour in Finokalia were discussed in the preceding Sect. 3.1. During the COPS campaign the size distributions varied greatly, and, as will be shown later, Aitken mode aerosol was more hygroscopic than accumulation mode aerosol, possibly explaining the behaviour of the COPS activation curve seen in Fig. 4 at least for higher levels (Irwin et al., 2010; Jones et al., 2011). Another location with seemingly different activation curves is Pallas, where the activation spectrum changes throughout the year, and even at fairly high level of 1.0 %, less than half of the total aerosol population activated into cloud drops. The long-term Jungfraujoch data set also exhibited comparatively low values, lower than those presented by Jurányi et al. (2011) and those during the CLACE-6 campaign at the same location (Fig. 4). While the values in the long-term Jungfraujoch data set were calculated with respect to CPC measurements of total particle number concentration, values for the CLACE-6 campaign and those reported by Jurányi et al. (2011) were calculated with respect to integrated SMPS size distribution measurements with a higher size cut-off. While the aerosol hygroscopicity at these locations will be discussed later, the effect of the size distribution on the activation curves is evident.
The similarity in how responds to at the majority of studied locations is an interesting result. In other words, at any given the annual mean fraction of aerosol that will activate into cloud drops is pretty much the same in many locations, a fact that was pointed out previously by Andreae (2009). This phenomenon can easily be illustrated using the example of the activation curve during the RHaMBLe cruise in the tropical North Atlantic. As will be discussed later, while the here is comparable to several other locations, the hygroscopicity of the aerosol is much higher, with the hygroscopicity parameter being just below unity across all studied sizes. Yet, the fact that the aerosol is so hygroscopic seems to affect the activation efficiency of the aerosol in a similar manner as, for example, during the PRIDE-PRD2006 campaign in southeastern China. During this campaign absolute was an order of magnitude higher than during the RHaMBLe cruise (Table 2), and the hygroscopicity was much lower (Rose et al., 2010). This order of magnitude difference in , a large difference in and at least some presumed difference in the shape of size distribution between the RHaMBLe cruise and the PRIDE-PRD2006 campaign seem to result in no apparent difference in the fraction of the aerosol that activates into cloud drops at any given . For most of the continental locations the overall fit presented in Table 4 can provide a reasonable estimation of annual mean based on the for any given . It should be kept in mind, however, that the activation curves in Fig. 4 for the long-term data sets do not reflect the potential short-term or seasonal variability, which, as can be seen in the example of the three Pallas campaigns, can be rather high. This and the fact that the short-term campaigns have been conducted during different seasons mean that the overall fit represents the annual mean activation behaviour and does not capture the variability on the shorter timescales.
Average effective activated fractions (/ and (/ as a function of supersaturation for the four long-term measurement locations.
[Figure omitted. See PDF]
One important uncertainty associated with the comparison of the activation curves in Fig. 4 is the precise size range from which is determined. In order for the activation curves to be directly comparable, the lower size limit of must be the same for all locations. In this study, data of the lower limit of for each location ( were unavailable and, hence, this parameter was likely to vary, complicating the comparison of activation curves in Fig. 4. To circumvent the problem, to conduct a more accurate comparison and to reveal more information about the effect of size distribution on CCN variability, and concentrations were used instead of to calculate the effective activated fractions corresponding to a certain lower cut-off diameter and , respectively. These were calculated for the four long-term measurement locations only (where the data were available), and the results of the comparison are depicted in Fig. 5. When is used instead of , the differences among locations described above almost disappear except for the lowest values of . In general, the activation curve of for Mace Head is similar to those for Hyytiälä, Vavihill and Jungfraujoch for above 0.4 %. In other words, when one considers the fraction of only accumulation mode particles that activates into cloud drops at any given , the difference in how affects at all examined locations diminishes. In Hyytiälä, Vavihill and Jungfraujoch, particles with a dry diameter of 100 activate at the of slightly higher than 0.2 % assuming an internally mixed aerosol. Around this Mace Head does exhibit a slightly higher compared to other locations, possibly due to the increased CCN activity of the organically enriched Aitken mode aerosol (Ovadnevaite et al., 2011).
When is examined in detail, the difference between Mace Head and other locations seen in Fig. 4 remains, with Mace Head exhibiting a higher activated fraction compared to the three other locations. In Hyytiälä, Vavihill and Jungfraujoch, particles with a dry diameter of 50 activate at a of %, while in Mace Head these same particles activate at a of %. Differences observed in Figs. 4 and 5 lead to the conclusion that and have a more stable dependence on ; i.e. the variability in the fraction of nucleation/Aitken mode particles among different locations is large. Consequently, when comparing data sets of activated fractions from several locations with different expected concentrations of nucleation/Aitken mode particles and instrumental set-ups, a recommendation is made for the consideration of using and/or concentrations instead of when calculating coupled with values derived from total number concentrations. Besides more systematic comparison of activation curves and, therefore, more accurate results, such an approach can provide additional information about the effect of size distribution and its variability, and hygroscopicity on CCN activation. The use of and also diminishes the effect of the spatial variability of the fraction of nucleation/Aitken mode particles, those less relevant for CCN activation at typical ambient levels.
Mean hygroscopicity parameter as a function of critical dry diameter for selected locations. Figure split in four panels for more detail. Shown with one standard deviation.
[Figure omitted. See PDF]
Median and percentile values for Aitken ( ) and accumulation ( ) mode particles for Hyytiälä, Vavihill, Jungfraujoch and Pallas A and C.
| Station | median | 25th percentile | 75th percentile | median | 25th percentile | 75th percentile | |
|---|---|---|---|---|---|---|---|
| Hyytiälä | 0.18 | 0.13 | 0.27 | 0.29 | 0.22 | 0.45 | |
| Vavihill | 0.20 | 0.15 | 0.28 | 0.27 | 0.22 | 0.33 | |
| Jungfraujoch | 0.18 | 0.12 | 0.28 | 0.22 | 0.16 | 0.31 | |
| Pallas A | 0.09 | 0.07 | 0.13 | 0.13 | 0.09 | 0.20 | |
| Pallas C | 0.18 | 0.15 | 0.27 | 0.25 | 0.19 | 0.37 | |
CCN and their hygroscopicity
Critical dry diameter and hygroscopicity parameter were provided for the majority of the presented locations, and the variation of with dry size is seen in Fig. 6 (the figure is split into four panels for better visual representation). The variation of with dry size is not the same everywhere, and three groups can be pointed out.
In the first group of locations clearly increases with size; this is the case for Hyytiälä, Vavihill, Jungfraujoch (Fig. 6, upper left panel), Pallas (Fig. 6, upper right panel), and for the four campaigns conducted by the MPIC (Fig. 6, lower right panel). At these locations accumulation mode particles have a higher hygroscopicity than the Aitken mode particles, likely due to cloud processing. The results of the Mann–Whitney test (Mann and Whitney, 1947) for two populations that are not normally distributed (below and above 100 of dry size; Paramonov et al., 2013) reveal that in Hyytiälä, Vavihill, Jungfraujoch and Pallas A and C the difference in is statistically significant at the 5 % significance level; i.e. the median of Aitken and accumulation mode particles are significantly different (Table 5). Published data for the PRIDE-PRD2006, CAREBeijing-2006, CLACE-6 and AMAZE-08 campaigns have previously reported such a trend (Rose et al., 2010, Gunthe et al., 2011, Rose et al., 2013 and Gunthe et al., 2009, respectively). Data for Chilbolton (Fig. 6, lower left panel) also reveal an increase in with size, although absolute values at this site may be underestimated due to the aerosol sample not being dried before entering the CCNC (Whitehead et al., 2014). Such behaviour of leads to two implications. First, as already discussed in Su et al. (2010) and Paramonov et al. (2013), the hygroscopicity of the whole aerosol population can, and in some cases should, be presented as a function of size; this can be done by way of either separate values for the Aitken and accumulation mode aerosol or hygroscopicity distribution functions. Values of derived from the CCNC are frequently discussed in conjunction with the chemistry information obtained, e.g. from the aerosol mass spectrometer (AMS) measurements. The second implication here is that if, due to instrumental limitations, such measurements are representative only of the accumulation mode particles, values derived from such measurements should be extended to the Aitken mode particles with caution. The effect of extending the accumulation mode down to the Aitken mode was examined using detailed data from Hyytiälä as an example. was calculated using the median annual size distribution and calculated with size-dependent and the assumed size-independent values. It was found that if of the accumulation mode is assumed to be the same for the Aitken mode, the , on average, is overestimated by 16 and 13.5 % for the of 0.6 and 1.0 %, respectively.
The second group of locations, or in this case only one location, exhibits a decrease of with particle dry size, and such a trend exists only for the COPS campaign (Fig. 6, lower left panel). Apparently, at the mountainous site in the Black Forest region of south-west Germany the chemical composition of the accumulation mode aerosol makes it less hygroscopic compared with the Aitken mode at supersaturated conditions (Irwin et al., 2010). However, the same study reported that the measurements by the hygroscopicity tandem DMA (HTDMA) in a sub-saturated regime revealed an increase of with particle dry size.
The third group of locations, represented by the K-puszta station and RHaMBLe measurement campaign, is characterised by the absence of any dependence of on the particle dry size. Though quite different in magnitude (Fig. 6, lower left panel), values and, therefore, aerosol chemical composition seem to have no particular size dependence across the whole measured size range. Also of interest is the high aerosol hygroscopicity across the whole investigated aerosol size range (Aitken mode) during the RHaMBLe cruise – all values are just below unity (Good et al., 2010). The marine nature of the aerosol and clean background conditions of the remote tropical North Atlantic are likely responsible for high aerosol hygroscopicity.
Monthly median at the of 0.1 % (upper) and 1.0 % (lower) for three long-term measurement locations. Error bars are 25th and 75th percentiles.
[Figure omitted. See PDF]
Three of the four long-term data sets, excluding Mace Head, included and data, making it possible to examine aerosol hygroscopicity both on the annual basis and diurnal basis separated by seasons. Figure 7 presents the annual variation of for lowest and highest levels in Hyytiälä, Vavihill and Jungfraujoch. As can be seen in the axis of the upper panel, particles measured at the of 0.1 % are in the accumulation mode, i.e. is larger than 100 in diameter. Of the three stations presented, has an annual pattern only in Hyytiälä, with a minimum and an increased hygroscopicity in the winter and a maximum and a decreased hygroscopicity in the summer, as previously reported by Paramonov et al. (2013). The likely reason for a decrease in the accumulation mode particle hygroscopicity in Hyytiälä in the summer is the increase in the emissions of the volatile organic compounds (VOCs), leading to an increase in secondary organic aerosol (SOA) formation and, thus, a higher organic fraction. The higher hygroscopicity in the winter can also be explained by a higher sulphate fraction, stronger aerosol oxidation and potentially other ageing processes that are known to increase particle hygroscopicity (Furutani et al., 2008). No annual pattern is present in the aerosol hygroscopicity of accumulation mode aerosol in Vavihill and Jungfraujoch. The lower panel in Fig. 7 depicts the annual variation of aerosol hygroscopicity for the Aitken mode aerosol, revealing no pattern for any of the three locations. The absence of a pattern coupled with the absence of an apparent difference among sites indicates that the aerosol hygroscopicity of Aitken, aerosol is fairly similar and constant throughout the year at all three locations.
Hourly median critical dry diameters at the of 1.0 % for three long-term measurement locations separated by seasons. Shaded areas represent the 25th and 75th percentiles, with colours corresponding to the median data series.
[Figure omitted. See PDF]
The diurnal patterns of aerosol hygroscopicity were analysed for Hyytiälä, Vavihill and Jungfraujoch on a seasonal basis. It was discovered that for the accumulation mode particles, those measured at the of 0.1 %, no diurnal pattern was observed at any of the three locations in any of the seasons, indicating that throughout the day photochemistry does not have any apparent effect on the hygroscopicity of the accumulation mode particles. Diurnal patterns of aerosol hygroscopicity for Aitken mode particles can be seen in Fig. 8. In the winter no particular pattern is visible at any of the locations; it can, however, be seen that while the aerosol hygroscopicity is similar between Hyytiälä and Vavihill, the Aitken mode aerosol at the Jungfraujoch is less hygroscopic. In the spring both Hyytiälä and Vavihill exhibit a clear diurnal pattern, which extends also into the summer. A peak in aerosol hygroscopicity is observed around midday when reaches its minimum. Several previous studies have reported such behaviour in Hyytiälä and have attributed it to the vegetation activity, photochemistry and the ageing of organics during sunlight hours (Sihto et al., 2011; Cerully et al., 2011; Paramonov et al., 2013). While no diurnal pattern of aerosol hygroscopicity is visible for Jungfraujoch for winter and spring, a very clear pattern does exist in the summer and autumn. In these seasons Aitken mode particles exhibit an obvious decrease in hygroscopicity in the afternoon shown by the peak in during these hours. This phenomenon has also been previously reported and attributed to the daytime intrusions of air from the planetary boundary layer (PBL) injecting less hygroscopic particles into the free troposphere (Kammermann et al., 2010a). The discussion above demonstrates that diurnal patterns of hygroscopicity are not the same everywhere and vary by seasons; however, the environments of Hyytiälä and Vavihill are similar enough to result in similar diurnal patterns.
Conclusion
CCNC measurement data from 14 locations, including four long-term measurement sites, have been analysed, compared and discussed with respect to the deduced CCN activation and hygroscopic properties. As already known, the pattern of how and respond to the increasing is indicative of the total concentrations, the size distribution of the pre-existing aerosol population and its hygroscopicity. Certain marine locations exhibited high values and rapidly increasing even at low values, as was the case during the COPS campaign in south-west Germany. At these locations aerosol populations are likely accumulation mode-dominated and/or of relatively high hygroscopicity. Pallas, a remote background location in northern Finland, exhibited a pattern of low values and slowly increasing at low values, revealing the likelihood of Aitken mode-dominated aerosol and/or fairly low hygroscopicity at this site. Jungfraujoch, a high Alpine site in the free troposphere, also exhibited comparatively low values, as the particle number is often dominated by the Aitken mode particles. For the rest of the studied locations (the majority), the pattern of increasing with increasing was similar, i.e. at most locations the same fraction of aerosol activated into cloud drops at any given . For example, 20 % of the total aerosol population at most locations will activate into cloud drops at the of 0.1 %. A simple linear fit for estimating annual mean at most continental locations is presented. When comparing activated fractions at several locations, a recommendation is made to use and/or when calculating values together with values derived from total number concentrations. Using this technique, a more accurate comparison should be performed for sites where the exact size range of is not known and where the concentrations of nucleation/Aitken mode particles are expected to be high, additionally revealing more information about the effect of size distribution and hygroscopicity on CCN activation.
The hygroscopicity of aerosol particles as a function of size is not the same at all locations; while decreased with increasing size at a continental site in south-west Germany and was fluctuating without any particular size dependence across the observed size range in the remote tropical North Atlantic and rural central Hungary, all other locations exhibited an increase of with size. In fact, at the rural background sites of southern Finland and southern Sweden, at a free troposphere site in the Swiss Alps and at a remote background site in northern Finland the difference in hygroscopicity between Aitken and accumulation mode aerosol was statistically significant at the 5 % significance level. Therefore, assuming a size-independent can lead to a substantial overestimation of at higher levels of (those above 0.6 %). The hygroscopicity of the whole aerosol population can be presented separately for Aitken and accumulation mode particles; additionally, hygroscopicity distribution functions can be used to analyse size-resolved CCNC data and efficiently describe the size dependence of (Lance, 2007; Su et al., 2010; Jurányi et al., 2013). It is known, however, that in most cases the size distribution and its variation have a larger effect on the than the particle hygroscopicity and its variation with size.
Among Hyytiälä, Vavihill and Jungfraujoch, no annual pattern of aerosol hygroscopicity was found for the Aitken mode aerosol. The accumulation mode aerosol exhibited a discernible annual pattern only in Hyytiälä, where a peak in hygroscopicity was found in February and a minimum in July. Such a pattern is likely attributed to the higher sulphate fraction and stronger aerosol oxidation in the winter and active SOA formation and higher organic fraction in the summer. Among the same three sites, no diurnal trend of aerosol hygroscopicity was found for accumulation mode aerosol. The hygroscopicity of the Aitken mode aerosol in Hyytiälä and Vavihill follows a clear diurnal pattern in the spring and summer – an increase in aerosol hygroscopicity was observed in the afternoon, likely due to the photochemistry and ageing of the organics. At the Jungfraujoch, Aitken mode aerosol showed a decrease in aerosol hygroscopicity in the afternoon during the summer and autumn; this phenomenon is caused by the injections from the planetary boundary layer containing somewhat less hygroscopic aerosol.
In general, the comparison of CCNC measurements is complicated by the variation of instrumental set-ups, settings, measurement times and intervals, performed calibrations, calculations and available parameters among sites. Supplementary data, such as aerosol size distribution and chemical composition, can enhance the uniformity of the analysis and expand the representativeness of the aforementioned results. However, as the first overview of its kind, the summary of CCNC measurements discussed here presents a unique insight into the CCN activation and hygroscopic properties in Europe and a few non-European sites. While, as shown here, CCNC measurements can provide useful information about the CCN and their activation into cloud droplets, the missing link in the aerosol–cloud interactions is the connection of CCN to the ambient CDNC. If filled, this gap can greatly improve our understanding of the processes and feedbacks within the aerosol–cloud–climate triangle and enhance the performance and accuracy of the global climate models.
Acknowledgements
The research leading to the results published herein has received funding from the ACTRIS Project of the European Union Seventh Framework Programme (FP7/2007-2013) under grant agreement no. 262254. Additional funding was provided by the Max Planck Society. HEA-PRTLI4 Environment and Climate: Impact and Responses programme, EC 6th Framework programme project EUCAARI (036833-2), EC 7th Framework programme project BACCHUS (603445) are all acknowledged. The authors would like to thank Jakub Bialek for collecting CCN data and Ciaran Monahan for SMPS measurements at Mace Head station. The authors would also like to thank Tuomo Nieminen, Nønne L. Prisle and Ari Asmi for the help with statistics and data analysis. Simon Schallhart, Ksenia Atlaskina and Anna Nikandrova are all gratefully acknowledged for the discussions, help and support with the data analysis and plotting. The Centre of Excellence in Atmospheric Science – from molecular and biological processes to the global climate FCoE, cryosphere–atmosphere interactions in a changing Arctic climate CRAICC initiative, KONE foundation and the Swedish Research Council (VR) are acknowledged as well. The measurements at the Jungfraujoch were supported by MeteoSwiss in the framework of the Global Atmosphere Watch programme and the infrastructure was supported by the International Foundation High Altitude Research Station Jungfraujoch and Gornergrat. M. Gysel was supported by the ERC under grant 615922-BLACARAT. Edited by: A. Petzold
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
© 2015. This work is published under http://creativecommons.org/licenses/by/3.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.
Abstract
Cloud condensation nuclei counter (CCNC) measurements performed at 14 locations around the world within the European Integrated project on Aerosol Cloud Climate and Air Quality interactions (EUCAARI) framework have been analysed and discussed with respect to the cloud condensation nuclei (CCN) activation and hygroscopic properties of the atmospheric aerosol. The annual mean ratio of activated cloud condensation nuclei (
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Details
; Aalto, P P 2 ; Andreae, M O 4
; Asmi, E 5 ; Baltensperger, U 3 ; Bougiatioti, A 6 ; Brus, D 7 ; Frank, G P 8 ; Good, N 9 ; Gunthe, S S 10 ; Hao, L 11 ; Irwin, M 12
; Jaatinen, A 11 ; Jurányi, Z 13 ; King, S M 14 ; Kortelainen, A 11 ; Kristensson, A 8 ; Lihavainen, H 5
; Kulmala, M 2
; Lohmann, U 15
; Martin, S T 16 ; McFiggans, G 17
; Mihalopoulos, N 6 ; Nenes, A 18 ; O'Dowd, C D 19 ; Ovadnevaite, J 19 ; Petäjä, T 2
; Pöschl, U 4
; Roberts, G C 20 ; Rose, D 21 ; Svenningsson, B 8 ; Swietlicki, E 8
; Weingartner, E 13
; Whitehead, J 17 ; Wiedensohler, A 22 ; Wittbom, C 8 ; Sierau, B 15 1 Department of Physics, University of Helsinki, P.O. Box 64, 00014 Helsinki, Finland; now at: Institute for Atmospheric and Climate Science, ETH Zurich, Zurich, Switzerland
2 Department of Physics, University of Helsinki, P.O. Box 64, 00014 Helsinki, Finland
3 Laboratory of Atmospheric Chemistry, Paul Scherrer Institute, 5232 Villigen PSI, Switzerland
4 Biogeochemistry and Multiphase Chemistry Departments, Max Planck Institute for Chemistry, Mainz, Germany
5 Finnish Meteorological Institute, Erik Palménin aukio 1, P.O. Box 503, 00101 Helsinki, Finland
6 Environmental Chemical Processes Laboratory, University of Crete, Heraklion, Greece
7 Finnish Meteorological Institute, Erik Palménin aukio 1, P.O. Box 503, 00101 Helsinki, Finland; Laboratory of Aerosols Chemistry and Physics, Institute of Chemical Process Fundamentals, Academy of Sciences of the Czech Republic, Rozvojová 135, 165 02 Prague 6, Czech Republic
8 Division of Nuclear Physics, Department of Physics, Lund University, P.O. Box 118, 22100 Lund, Sweden
9 Centre for Atmospheric Science, SEAES, The University of Manchester, Oxford Road, Manchester M13 9PL, UK; now at: Department of Mechanical Engineering, Colorado State University, Fort Collins, CO, USA
10 Biogeochemistry and Multiphase Chemistry Departments, Max Planck Institute for Chemistry, Mainz, Germany; now at: Department of Civil Engineering, Indian Institute of Technology Madras, Chennai, India
11 Department of Applied Physics, University of Eastern Finland, 70210 Kuopio, Finland
12 Centre for Atmospheric Science, SEAES, The University of Manchester, Oxford Road, Manchester M13 9PL, UK; now at: Cambustion Ltd., Cambridge, UK
13 Laboratory of Atmospheric Chemistry, Paul Scherrer Institute, 5232 Villigen PSI, Switzerland; now at: Institute of Aerosol and Sensor Technology, University of Applied Sciences Northwestern Switzerland, Windisch, Switzerland
14 School of Engineering and Applied Sciences and Department of Earth and Planetary Sciences, Harvard University, Cambridge, MA 02138, USA; now at: Haldor Topsøe A/S, Copenhagen, Denmark
15 Institute for Atmospheric and Climate Science, ETH Zurich, Zurich, Switzerland
16 School of Engineering and Applied Sciences and Department of Earth and Planetary Sciences, Harvard University, Cambridge, MA 02138, USA
17 Centre for Atmospheric Science, SEAES, The University of Manchester, Oxford Road, Manchester M13 9PL, UK
18 School of Earth and Atmospheric Sciences, Georgia Institute of Technology, Atlanta, GA 30332, USA; School of Chemical and Biomolecular Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA; Institute of Chemical Engineering Sciences (ICE-HT), FORTH, Patras, Greece
19 School of Physics and Centre for Climate and Air Pollution Studies, Ryan Institute, National University of Ireland Galway, University Road, Galway, Ireland
20 Centre National de Recherches Météorologiques, Toulouse, France; Scripps Institution of Oceanography, University of California San Diego, La Jolla, CA 92093, USA
21 Biogeochemistry and Multiphase Chemistry Departments, Max Planck Institute for Chemistry, Mainz, Germany; now at: Institute for Atmospheric and Environmental Sciences, Goethe-University Frankfurt am Main, Frankfurt am Main, Germany
22 Leibniz Institute for Tropospheric Research, Leipzig, Germany