Introduction
Many fine particle (PM) chemical components have been reported as potential contributors to particle toxicity that can lead to various adverse health endpoints, including secondary sulfates (Atkinson et al., 2010; Maynard et al., 2007; Pope et al., 2002), elemental carbon (Kleinman et al., 2007; Brunekreef et al., 1997), metals (Gasser et al., 2009; Burchiel et al., 2005; Pope et al., 2002; Burnett et al., 2000), organic carbon (Kleinman et al., 2007; Nel et al., 2001), semi-volatile organic species (Seagrave et al., 2005; Seagrave et al., 2002), and polycyclic aromatic hydrocarbons (PAHs) (Lundstedt et al., 2007; Burchiel et al., 2005). Identifying the components of aerosols that are responsible for health effects provides a means for effective air quality mitigation by controlling specific sources.
Metals are known to exert pro-oxidant and pro-inflammatory effects in the respiratory system (Cho et al., 2011; Li et al., 2010), and the water-soluble fraction of metals are of special interest as they are more bioavailable (Heal et al., 2005; Shi et al., 2003) and may have a higher risk potential. For example, a study with concentrated ambient particles (CAPS) associated inflammatory endpoints (pulmonary and hematological responses) to water-soluble Fe/Se/S and Cu/Zn/V factors (Huang et al., 2003). Another CAPS study found that the plasma fibrinogen levels (a coronary risk indicator) in spontaneously hypertensive rats were better correlated with water-soluble metals (especially Zn) than total PM mass (Kodavanti et al., 2005). PM water-soluble metals were found to be significantly associated with small reductions in birth weight (Darrow et al., 2011) and daily pre-term birth rates (Darrow et al., 2009) in an Atlanta, GA, study.
Water-soluble transition metal toxicity may be due to their ability to generate free radicals, for example, via redox cycling with biological reductants (Chevion, 1988; Stohs and Bagchi, 1995). Transition metals have varying oxidation states, thus metals, especially Fe and Cu, can act as a catalyst for the reactions, e.g., Fenton reaction that convert hydrogen peroxide to the more toxic hydroxyl radicals (Liochev and Fridovich, 2002; Stohs and Bagchi, 1995). Metal-mediated formation of free radicals may lead to DNA modifications, enhanced lipid peroxidation, and altered calcium and sulfhydryl homeostasis (Valko et al., 2005). Water-soluble transition metals have been identified as the potential contributors to reactive oxygen species (ROS) production by different ROS probes such as the DTT (dithiothreitol) (Charrier and Anastasio, 2012), AA (ascorbate acid) (Strak et al., 2012; Fang et al., 2015b), and macrophage (Saffari et al., 2014; Verma et al., 2010) assays.
Since most metals in PM have low solubilities (e.g., Zn 50 %, Cu and Mn 10–40 %, Fe 10 %) (Birmili et al., 2006; Espinosa et al., 2002), total element concentrations may not represent the potential effects of the roles of redox-active metals on human health. The objective of this work, within the framework of the Southeastern Center for Air Pollution & Epidemiology (SCAPE) study, was to provide a reliable measurement of PM water-soluble element concentrations from filter samples collected at seven sites in the southeastern USA that represent different degrees of anthropogenic and traffic influence. A cost-effective and automated method was required since over 500 filters were available for analyses. The resulting unique large and comprehensive data set allowed for robust statistical analyses and has informed studies on particle ROS generating activities based on the DTT (Verma et al., 2015; Verma et al., 2014) and AA assays (Fang et al., 2015b). The data have provided new insights into the health effects of particulate water-soluble metals. This work focuses on a description of the measurement techniques, discussion on the spatiotemporal distribution, and source apportionment of water-soluble elements, with a specific focus on four important health-related water-soluble metals (Fe, Cu, Mn, and Zn).
Schematic of automated system developed to measure elements in the water-soluble aerosol extracts using an online XRF element analyzer (Xact 625).
[Figure omitted. See PDF]
Methods
The present work involves measuring water-soluble elements from filter extracts by re-aerosolizing the extract and sampling with an online X-ray fluorescence (XRF) instrument. The ambient mass concentrations of the following water-soluble elements were quantified: S (sulfur), Ca (calcium), K (potassium), Fe (iron), Cu (copper), Zn (zinc), Ba (barium), Pb (lead), As (arsenic), Sr (strontium), Se (selenium), Br (bromine), Mn (manganese), and Ti (titanium). S is also included in the discussion since it is a source indicator for secondary processing.
Sampling sites and filter preparation
Sampling sites
As part of the SCAPE study, 23 integrated PM samples were collected on pre-baked (max temperature: 550 C, time ramp: 3.5 ) quartz filters (Pallflex Tissuquartz, inches) from noon to 11 a.m. the following day with high-volume (Hi-Vol) samplers (Thermo Anderson, flow rate normally 1.13 ) in Atlanta, GA, Birmingham and Centerville, AL, and East St. Louis, IL. The sites were
Jefferson Street, GA (JST), a central site representative of the Atlanta urban environment, also a stationary site in this study where one Hi-Vol sampler was operated for most of the study period;
Yorkville, GA (YRK), a rural environment, situated in an agricultural region located approximately 70 west of JST;
Road side, GA (RS), adjacent to an interstate highway (I75/85) in midtown Atlanta;
Georgia Tech, GA (GT), a rooftop site on Georgia Tech campus, roughly 30 above ground level, 840 from the RS site, providing an intermediate location between RS and the central urban site (JST);
Birmingham, AL (BHM), an urban site within a few kilometers of significant transportation and industrial sources;
Centerville, AL (CTR), the rural pair of BHM, surrounded by forests and a lightly traveled rural road;
East St. Louis, IL (Sauvain et al., 2008), an urban residential/light commercial area approximately 3 east of the central business district of St. Louis, MO.
Filter preparation
Four punches of the Hi-Vol filter (5.07 each) were extracted in 15 of deionized (DI) water ( ) in a sterile polypropylene centrifuge tube (VWR International LLC, Suwanee, GA, USA) by sonication (Ultrasonic Cleanser, VWR International LLC, West Chester, PA, USA) for half an hour. Extracts were then filtered using PTFE 0.45 syringe filters (Fisherbrand to remove insoluble material; 120 of high purity (OmniTrace Ultra Nitric Acid, 67–70 %, EMD Millipore Corporation, Billerica, MA, USA) was then added to 6 of the extract (resulting pH ) to ensure the suspension of all dissolved metals, and were then transferred to a 5 DIONEX autosampler vial (PolyVial, Thermo Scientific). Some insoluble elements that are smaller than 0.45 in diameter can be included in the water-soluble fractions defined by this method. It is also noted that water-soluble element concentrations are operationally defined by the extraction method, and may differ from how elements are dissolved in vivo.
Methods for measuring water-soluble element concentration
A Xact 625 automated multi-metals monitor (Cooper Environmental, OR, USA) was used to measure the concentration of elements in the liquid samples. The Xact collects particles on a reel-to-reel (RTR) Teflon filter tape, sampling at 16.7 for a user selected time interval (30 in this case), resulting in a concentrated PM spot on the tape. After the preset sampling interval, the tape is automatically advanced, positioning the PM spot for non-destructive XRF analyses to quantify the mass of multiple elements. At the same time, the next sampling is initiated on a fresh tape spot. XRF response is calibrated using a series of metal film standards on B36 mount nucleopore membranes (Nano XRF, Fort Worth, TX, USA), including appropriate interference element analytes. With each sample, the Xact also includes a measurement of pure palladium as an internal standard to automatically adjust the detector energy gain.
To introduce water-soluble metals from filter extracts in Xact, a computer-controlled auto-sampling system was set up using a Dionex autosampler, a multi-port injection valve and a continuous flow nebulizer so that sampling and analysis could be performed continuously, except during daily automated quality assurance checks ( ). A schematic diagram of the overall system is shown in Fig. 1. At “load” position, liquid sample (at least 6 ) was loaded by a DIONEX automated sampler (AS40, DIONEX Corporation, Sunnyvale, CA, USA) through a SelectPro two-position fluid processor valve (Alltech, Deerfield, IL, USA) to a 5 PEEK sample loop (Upchurch Scientific, Inc., Oak Harbor, WA). After 2.5 , at which point the sample loop had been completely filled with extract liquid from the Dionex autosampler, the valve was switched to the “inject” position and all 5 mL of sample injected to an ultrasonic nebulizer (CETAC U5000 AT, CETAC Technologies, Omaha, NE, USA) via a carrier DI flow of 0.42 (DI, Fig. 1) propelled by a peristaltic pump (Ismatec, Cole-Parmer Instrument Company, Vernon Hills, IL, USA). In the continuous flow ultrasonic nebulizer, liquid sample was converted to a fine aerosol spray and directed by filtered carrier room air of 1.62 through an evaporator at 136 C followed by a condenser at 3 C. The dry aerosolized sample was neutralized by a Kr-85 (Model 3077A, TSI) ion source and then mixed with clean filtered (Pall HEPA Capsule) make-up air drawn into the Xact and through the filter tape by the Xact's flow control system. After 14 , at which point all sample in the sample loop had been transferred to the Xact filter tape, the system switched to load position again, and DI water with (final concentration %) was loaded onto the sample loop (2.5 ), after which the system switched to inject position again, and the 2 % was directed to the nebulizer and the Xact. This cycle was performed to wash off any metal residuals in the liquid system. After 11 , the filter tape was automatically advanced to a position where total mass for each element from the sample was measured by XRF analysis. At the same time, the system repeated the process for measuring the next sample (i.e., load sample-inject sample-load 2 % -inject 2 % , 2.5-14-2.5-11 cycle). To further ensure no carry-over between samples, a faster DI flow (DI, 2.09 , Fig. 1) was used for flushing while the SelectPro valve was at the load position. Inserting 2 % between samples was found to be an effective method to eliminate carry-over between samples (Fig. S2, Supplement).
The final ambient concentration of each element was calculated as follows: where is the specific element ambient concentration (); ( and ( are the concentration of element () and volume of air () drawn through the filter tape for sample (blank), respectively, both reported by the XRF in the 30 sampling time. the volume of DI water used for the filter extraction is 15 and the sample liquid volume loaded to the Xact is 5 . is the total particle collection area of the Hi-Vol filter () and is the area used for this analysis (). is the Hi-Vol sampling flow rate ( ) and is the sampling duration (). is the calibration factor determined by multiple external element standard solutions, discussed below (Sect. 2.3).
System calibration based on multiple element-ion standard solutions. Error bars represent the standard deviation of three replicates. Slopes and intercepts are based on orthogonal regression with errors as 1 standard deviation.
[Figure omitted. See PDF]
A similar automated system with the DIONEX sampler, SelectPro valve, and a peristaltic pump was also used to measure water-soluble organic carbon (WSOC) on the extracts from the same Hi-vol filters. Filter extracts ( ) that had been loaded into a 5 sample loop, were first passed through a 1 Liquid Wave-guide Capillary Cell (LWCC-M-100; World Precision Instruments, Inc., FL, USA), where absorbance at 365 wavelength (BrC) was measured (not included in this work). The extracts then entered a TOC analyzer (Sievers Model 900, GE Analytical Instruments, Boulder, CO, USA) for determining WSOC concentration (Sullivan et al., 2006).
Calibration
Multiple element-ion standard stock solutions [, , , , , and ] were prepared by dissolving powders in DI water with (2 % final concentration) and stored in a refrigerator ( C). and were obtained from Sigma-Aldrich; , , and were obtained from Alfa Aesar; was from Fisher Scientific. Final standard solutions were diluted from stock (20–200 times dilution), 2 % added, transferred to DIONEX vials, and ran through the same system as described above.
Figure 2 shows the system calibration using serial dilutions of multiple element-ion standards. Linear regression yielded larger than 0.98 for all cases and similar slopes (0.47–0.60), indicating that the nebulizer efficiency and other losses in the system were not dependent on the specific element. Slopes from measured mass versus calculated mass of element-ion standard solutions for all standards were averaged and used as the calibration factor ( in Eq. 1) to interpret all elements in samples. The intercepts were not included in the final ambient concentration calculation (Eq. 1) since the intercept of sample and blank cancel out after blank subtraction. The standards were made in the range of typical sample concentrations and the intercepts were negligible ( % of typical ambient levels). One standard ion solution was measured for every five filter samples and the coefficients of variation (CV, calculated as standard deviation (/mean, %) were less than 10 % throughout the analyses of all filters, indicating that the system was capable of stable and reproducible operation.
Limits of detection (LOD), blanks () and uncertainties for all water-soluble elements.
Element | LOD, | Blank, | Analytical | Sum of square of | Uncertainty from | Overall |
---|---|---|---|---|---|---|
uncertainty, % | various uncertainties, % | collocated measurements, % | uncertainty, % | |||
Sulfur (S) | 6.19 | 6.64 | 2.19 | 7.77 | 2.38 | 8.13 |
Potassium (K) | 16.45 | 11.80 | 2.47 | 9.89 | 6.06 | 11.63 |
Calcium (Ca) | 29.64 | 32.23 | 2.38 | 10.46 | 11.76 | 15.87 |
Titanium (Ti) | 0.09 | 0.06 | 15.79 | 21.08 | 18.68 | 28.22 |
Manganese (Mn) | 0.11 | 0.06 | 3.57 | 8.54 | 6.49 | 10.74 |
Iron (Fe) | 3.11 | 1.54 | 12.59 | 13.94 | 14.06 | 19.83 |
Copper (Cu) | 0.91 | 0.70 | 2.37 | 8.57 | 23.85 | 25.38 |
Zinc (Zn) | 1.87 | 1.89 | 4.56 | 9.90 | 8.24 | 12.90 |
Selenium (Se) | 0.02 | 0.01 | 8.94 | 12.17 | 7.79 | 14.46 |
Bromine (Br) | 0.03 | 0.02 | 3.93 | 8.50 | 4.49 | 9.62 |
Strontium (Sr) | 0.11 | 0.08 | 3.57 | 9.63 | 23.53 | 25.46 |
Barium (Ba) | 1.13 | 0.37 | 3.29 | 10.59 | 14.08 | 17.73 |
Arsenic (As) | – | 0 | 6.97 | 10.17 | 3.53 | 10.77 |
Lead (Pb) | 0.14 | 0.12 | 7.45 | 11.77 | 1.32 | 11.85 |
Blanks, LOD, and uncertainties
The limits of detection (LOD) based on blank levels obtained from Hi-Vol filter blanks (), and various uncertainties, as well as overall uncertainties for all elements are given in Table 1. The concentration of blanks was calculated using Eq. (1) assuming 23 sampling at 1.13 and LOD was determined by 3 times the standard deviations of blanks. Values below LOD for S, K, Ca, Ti, Mn, Fe, Cu, Zn, As, Se, Br, Sr, Ba, and Pb were assigned as half of LOD values in all the statistical analyses below. Other elements detected by the Xact, such as Sc (scandium), V (vanadium), Cr (chromium), Co (cobalt), Ni (nickel), Ge (germanium), Rb (rubidium), Ag (silver), Cd (cadmium), and Hg (mercury), for which % of aerosol samples were below the detection limits, are not included in the table or subsequent discussion. Calculation of uncertainties are discussed in Sect. 2.5. For most elements, overall uncertainties are less than 20 %. Ti, Sr, and Cu have the highest uncertainties of 28, 25, and 25 %, respectively.
Sulfur measured by XRF and one-third of sulfate measured by IC (results of orthogonal regression are shown, along with ratio by dotted line).
[Figure omitted. See PDF]
Source apportionment
A source apportionment analysis was performed with positive matrix factorization (PMF) (Paatero and Tapper, 1994) using EPA PMF 5.0 software. PMF analysis was applied on the combined data from JST (summer, fall, winter 2012, and spring 2013), GT (fall, winter 2012, and fall 2013), and RS (winter 2013 and fall 2013) (total ). Although the road-side site generally has higher levels of metals than the urban site (JST) and near-road site (GT) (discussed in Sect. 3.2.2), merging RS data with JST and GT in the analysis did not alter the PMF solutions substantially (factor profiles and source contributions), but the larger number of input data resulted in a more robust PMF solution. Fourteen elements (S, K, Ca, Ti, Mn, Fe, Cu, Zn, As, Se, Br, Sr, Ba, and Pb) and WSOC were run in the model with Ti and As categorized as weak species (low S/N signals). The concentrations, together with the uncertainties, were used as the input for PMF runs. Missing data were replaced by species median with 400 % uncertainty and values below LOD were assigned as half of LOD values with uncertainties of five-sixths the concentration (Polissar et al., 1998). For other data, uncertainties for each species were determined by multiplying the concentration by overall uncertainties (%). Overall uncertainty was calculated from the sum of square of various uncertainties including filter sampling (5 %), extraction (5 %), blanks (1 of multiple blanks, 2–15 % depending on species), calibration (1 of slope, 10 %), and analytical uncertainty. The analytical uncertainty for elements was obtained by analyzing the same sample, a composite of extracts from 11 selected road-side samples 20 times and calculating the coefficient of variation (CV, %). The measured uncertainty for each element, based on two side-by-side Hi-Vol samplers at JST, was also included in the overall uncertainty. This was done because the calculated uncertainties for some elements (e.g., Cu and Sr) are much smaller than the measured uncertainties from collocated measurements (Table 1). By combining two uncertainties, the uncertainties for all elements are slightly overestimating. Uncertainty from collocated measurements was calculated as the relative uncertainty of the slope (1 /slope), which was based on an orthogonal regression (discussed below, see Fig. 4). Both uncertainties and the combined overall uncertainties for each element are given in Table 1. The PMF model was executed with 3–8 factors. Based on minimized values and physical interpretation of the solutions, a four-factor solution was found to be optimal. Details on determining the optimal factor and bootstrapping results can be found in the Supplement.
Precision from collocated measurements assessed by filter samples () collected simultaneously using two Hi-Vol samplers deployed at JST during November 2012 (analysis was done by orthogonal regression; the dotted line is ).
[Figure omitted. See PDF]
Results and discussions
Comparison with ion chromatography
As a further test of the system, sulfate concentrations were determined on a subset of the Hi-Vol filter samples by ion chromatography (IC) and compared to the elemental analysis of sulfur; 200 filters that included samples from JST and GT were extracted in DI water (same procedure discussed in Sect. 2.1, but without adding in the extracts), and inorganic sulfate (IC-sulfate) was measured by an ion chromatography (IC, DX500 with UTAC-ULP1 concentrator column, AG11 guard column, and AS11 anion column, DIONEX, CA). IC-sulfate was then divided by three to convert to sulfur mass (molar mass of sulfate and sulfur are 96 and 32 , respectively) and directly compared to XRF-sulfur. Orthogonal regression shows good quantitative agreement and correlation coefficient ( of 0.96 (Fig. 3). The discrepancy between sulfur measured by XRF and IC (slope of IC-sulfur vs. XRF-sulfur ) may be attributed to roughly 20 % contributions from additional sulfur species, such as organosulfates that are not detected by the IC. Lower sulfur measured by IC versus XRF has also been observed in other studies (Shakya and Peltier, 2015; Tolocka and Turpin, 2012; He et al., 2001). However, Hidy et al. (2014) found no statistical evidence for organosulfates in the southeast by this difference method.
Water-soluble elements
Inter-comparisons of two collocated Hi-Vols
Inter-comparisons of elements from two collocated Hi-Vol samplers () at JST in November 2012 are shown in Fig. 4, and results included in Table 1. Orthogonal regressions resulted in strong correlations for most elements (–0.99) with moderate correlations for Cu () and Sr (). The slopes show percentage differences (1-slope) are 1–10 % for Cu, K, and Ti, 11–20 % for S, Zn, Ca, Br, As, and Sr, and 20–36 % for Pb, Mn, Se, Fe, and Ba. Overall, the two Hi-Vols show good agreement for measuring water-soluble elements, considering the uncertainties from sampling, filter preparations, and extractions. The uncertainties in slope (1 were used in calculating the overall uncertainties (Sect. 2.3). The intercepts were relatively small and thus ignored.
Monthly mean ( standard deviation) of water-soluble elements ambient concentration () at various sampling sites. Seasons are separated by solid lines and simultaneous sampling at paired sites are separated by dashed lines (urban – JST, BHM, ESL; rural – YRK, CTR; near-road – GT; road-side – RS).
[Figure omitted. See PDF]
Spatial and temporal trends
Monthly average concentrations of water-soluble elements and WSOC at various sampling sites are given in Figs. 5 and Fig. S9, respectively. Three seasons (summer, fall, and winter) were grouped based on the temperature profiles in 2012 and 2013, consistent with our previous work (Fang et al., 2015a; Verma et al., 2014). As seen from Fig. 5, mass concentrations of water-soluble elements span a wide range, from 0.1 to 1.2 . S is the most abundant water-soluble element of the group measured, comprising % of the total measured element mass. Ca, K, Fe, Cu, Zn, and Ba follow with average ( fractions of 16 () %, 8 () %, 1.8 () %, 1.4 () %, 1.4 () %, and 0.5 () %.
Seasonal variability of all elements can be examined from the Atlanta urban sites (JST, GT, and RS). Besides S, commonly found to have higher concentration in summer due to the higher oxidation rates in warm seasons (Hidy et al., 2014), most of the water-soluble elements also had higher concentrations in summer/fall, such as Ca, Fe, Cu, Mn, Sr, and Se. The seasonal variability of these elements may be explained by different causes: elevated concentration of some elements (Ca, Mn, and Sr) may be attributed to drier conditions in summer favoring the re-suspension of mineral dust; Cu and Fe may be related to secondary formation (discussed in the source apportionment in Sect. 3.2.3); and Se is likely due to its coal combustion origins (Bell et al., 2007), thus following a similar trend as S. In contrast, K can be associated with both biomass burning and mineral dust (Zhang et al., 2010; Hueglin et al., 2005) (discussed below and Fig. S3 in the Supplement) and has less seasonal variability, with only slightly higher concentrations in winter due to more biomass burning during that period. Other metals (Zn, Ba, Br, Pb, Ti, and As) do not exhibit apparent seasonal trends.
Correlations (Pearson's r) between paired sites for various water-soluble elements in Georgia (JST, RS, GT, and YRK).
[Figure omitted. See PDF]
Spatial variability of water-soluble elements is important in assessing human exposure, within/across cities, for epidemiological studies, and provides insights on sources. The BHM site has high ambient concentration of most water-soluble metals, such as Mn, Zn, and Pb, with respect to other sites, pointing to industrial sources for these metals in this urban environment. The ratio of averaged Mn, Zn, and Pb at BHM to its paired rural site CTR is 3.3, 7.0, and 5.7, respectively. ESL, an urban site also strongly impacted by numerous industrial sources (Bae et al., 2006), has the highest Ca and Se concentrations among all sites, and higher Mn and Pb than all Atlanta sites (JST, GT, RS, and YRK). Among the four sites in Atlanta, there was a distinct relationship between the concentration of water-soluble elements and distance to traffic sources. Generally, the road-side (RS) site had much higher element concentrations relative to the rural YRK site, which had notably low concentrations of Cu, Ba, Sr and Ti. For example, the ratio of averaged Cu, Ba, Sr, and Ti at RS to its paired Atlanta urban JST site, is 0.9, 3.4, 2.2, and 2.6, respectively, in fall and 3.3, 3.1, 4.6, and 1.9 in winter. Comparing RS to the near-road GT site, ratios are 2.2, 2.7, 2.5 and 2.6 in fall for Cu, Ba, and Ti. Concentrations at YRK were typically much lower than the paired JST urban site, both in summer (ratio of average concentration YRK/JST , 0.3, 0.5, and 0.5) and winter (0.4, 0.4, 0.4, and 0.3) for Cu, Ba, Sr and Ti, respectively.
To further explore the spatial heterogeneity of water-soluble elements in Atlanta and the surrounding region, the coefficient of divergence (COD) (Wilson et al., 2005) and correlation coefficient (Pearson's r) were calculated for each paired site for all elements. A COD close to 0 represents a homogenous distribution, and near 1 indicates heterogeneity. Both are summarized in Table S2 (Supplement), and values are shown in Fig. 6. The COD and correlation coefficient () for WSOC were also included in Table S2 in the Supplement.
JST and GT are in close proximity. These two sites had the most similar concentrations for many water-soluble elements, with r ranging from 0.71 to 0.98 and relatively low CODs (0.06–0.20), except for Cu and Ti. In summer Cu measured at JST and GT have a moderate correlation () but high COD (0.52), with much higher concentration at JST (mean 19.1 , median 18.5 ) than GT (mean 6.6 , median 5.1 ). In winter, although the average values are similar (3.7 and 3.6 for JST and GT, respectively), there is no correlation () and COD is fairly high (0.35). Ti between the two sites have low correlations ( in summer and 0.51 in winter) and high COD (0.38 and 0.36 in summer and winter, respectively).
For the urban/rural (JST/YRK) pair, S, K, Ca, Mn, and Se tended to co-vary and have similar concentrations at the urban and rural sites, pointing to a more regional characteristic (sources) for these elements. The other elements did not co-vary at these two sites and are generally higher at the urban site (JST).
Comparison of the road-side site (RS) to the representative urban site (JST) provides insights into which elements are associated with traffic emissions and how they vary with season. S and K were not correlated well between JST and RS in both fall and winter, suggesting the presence of other local sources for S and K at the RS site, for example re-suspended dust (Minguillón et al., 2014; Hueglin et al., 2005). For Cu, Ba, Sr and Ti, the high COD (), low values () between various paired sites, and their concentrations highest at RS, are all indicators of emissions associated with traffic as a dominant source (Fig. 5).
Loading of measured water-soluble elements into various PMF resolved factors for all Atlanta sites (a) and factor time series of source contributions resolved from the Jefferson Street Site (JST, urban Atlanta) (b).
[Figure omitted. See PDF]
Factor contributions for water-soluble Cu, Zn, Mn, and Fe in PM based on the PMF analyses.
[Figure omitted. See PDF]
Source apportionment
PMF was applied to the combined data from JST, GT, and RS (total ), and four factors were resolved. They are labeled brake/tire wear, biomass burning, secondary formation, and mineral dust, based on the loading of specific elements identified as various source tracers. Note, metals as source tracers are typically based on total metals, whereas here we are using the measured water-soluble concentrations. Factor profiles and time series plots (from the JST site) are shown in Fig. 7a and b, respectively. The percentage contribution of the various factors (sources) to the four important health-related metals (Cu, Fe, Zn, and Mn) is shown in Fig. 8. Breakdown of sources for the other water-soluble elements and WSOC can be found in Fig. S3 in the Supplement.
The factor with high loadings for Ti, Fe, Cu, Zn, and Ba is identified as a brake/tire wear source as it includes products from brake pads or linings, such as Cu (Adachi and Tainosho, 2004; Sternbeck et al., 2002; Garg et al., 2000), Fe (Adachi and Tainosho, 2004; Garg et al., 2000; Hopke et al., 1980), Ti (Adachi and Tainosho, 2004), and Zn (Adachi and Tainosho, 2004; Sternbeck et al., 2002), and tracers of tire wear, e.g., Zn (Harrison et al., 2012). A biomass burning factor is identified by high concentrations of K, Br, As, and Pb. While K is a typical component in biomass burning aerosols, Br (Turn et al., 1997) and Pb (Richard et al., 2011) have also been found in wood combustion. The time series plot (Fig. 7b) showed a higher contribution of this factor in winter than in summer (winter/summer), consistent with the observed winter enhancement of biomass burning emissions in Atlanta (Zhang et al., 2010). Some water-soluble metals (e.g., Se, Fe, Br, Pb, As, Mn, Ba, and Zn) were apportioned to the biomass burning factor (see Figs. 8 and S3 in the Supplement). The total form of some of these metals (Fe, Mn, Zn, and Cu) (Chang-Graham et al., 2011) and water-soluble Fe have been seen in biomass burning in other studies (Oakes et al., 2012). The third factor, referred to as secondary formation, is characterized by high S, WSOC, and Se, and some Fe, with higher contributions in summer than winter (summer/winter). For the last source, a mineral dust origin is suggested by high loadings of Ca, Mn, and Sr, all indicators of crustal material. The results have implications for health studies.
Redox-active transition metals: Cu, Fe, and Mn
A number of studies have linked water-soluble redox-active Cu, Fe, and Mn to reactive oxygen species (Cheung et al., 2012, 2010; Kam et al., 2011; Shen and Anastasio, 2011; Akhtar et al., 2010; Landreman et al., 2008; Zhang et al., 2008; Kodavanti et al., 2005). After S, K, and Ca, these metals (i.e., water-soluble Cu, Fe, and Mn) generally have higher ambient concentrations than other measured elements (Fig. 5). In addition, Cu and Mn are thought to make major contributions to particle-catalyzed ROS generation (e.g., DTT (dithiothreitol) assay (Charrier and Anastasio, 2012)). Exploring the sources of the water-soluble fractions of these metals is pertinent to our health studies.
As shown in Fig. 8, tire/brake wear is the dominant source for Cu (51 %). It is also strongly correlated with Ba (–0.84, Table S3 in the Supplement) at the road-side site (RS), and Ba is a good indicator for a brake lining source (Gietl et al., 2010; Torre et al., 2002). The other important contributor to Cu is secondary formation (39 %).
Although Zn is not redox-active, we include it here in the discussion since it was also significantly loaded in the tire/brake wear factor (45 %) and has been linked to adverse health effects (Akhtar et al., 2010; Kodavanti et al., 2005). PMF analyses suggests that Zn has additional sources, with 26 % associated with the mineral dust factor, 14 % with the biomass burning, and 13 % with secondary formation. Zn is also correlated with other water-soluble metals, to various degrees (Fe, Pb, Mn, Sr, K, Ca, Ti, and Cu with ranging from 0.70 to 0.89, Table S3 in the Supplement).
Overall, the results (Fig. 8) show that brake/tire wear is an important traffic source for Cu (51 %), Fe (32 %), Mn (17 %), and Zn (45 %). Studies have specifically linked these metals from break wear, or traffic sources in general, to pro-inflammatory responses (e.g., Gasser et al., 2009) and observed adverse health responses (e.g., Riediker et al., 2004). Combined with engine combustion emissions, which includes many organic components (e.g., quinones), the large fraction of water-soluble Cu, along with contributions from Fe and Mn from brake/tire wear, make mobile source emissions important ROS sources (Bates et al., 2015). In contrast, these redox-active metals are not found at significant levels in the biomass burning factor (Fig. 7), which has been found to be a contributor to the PM DTT activity in the SCAPE study (Verma et al., 2014, 2015; Bates et al., 2015), indicating that redox-active organic species dominate in that case.
The major identified source for Mn is mineral dust (45 %) with other sources making relatively similar contributions: secondary formation (18 %), biomass burning (16 %), and brake/tire wear (17 %). At YRK, the rural site least affected by traffic, Mn correlates best with Ca () and Sr (, Table S3) in summer and K (), Ca (), Zn (), and Sr () in winter, all indicative of regional mineral dust contributions, consistent with the regional characteristic of Mn discussed in Sect. 3.2.2.
For Fe, besides the brake/tire factor, a large fraction (47 %) is apportioned to the secondary formation factor, and Fe correlates well with S at JST (), YRK (), and GT () in summer, and at JST () in fall 2012 and RS () in fall 2013. Fe and S are moderately correlated at RS in fall 2012 (), and GT () in fall 2013. The highest correlations occur when secondary atmospheric processing (oxidation) is strong. These results are consistent with a previous study involving single particle chemical analysis on PM particles in Atlanta, which showed that sulfate is an important proxy for Fe solubility (Oakes et al., 2012) by affecting aerosol pH, or as an indicator of iron sulfates, which are soluble and possibly formed at some point earlier in the particles lifespan under acidic conditions. Metal mobilization by formation of an aqueous particle with secondary acids may also explain the important contribution of secondary formation (39 %) to Cu in the southeastern USA, although the correlations between Cu and S were weaker compared to those between Fe and S (Cu – S , 0.09, and 0.66 at JST, YRK, and GT in summer, respectively, Table S3). The correlation between S and water-soluble Fe and Cu might explain past associations found in other studies between sulfate/sulfur oxide and health endpoints (Atkinson et al., 2010; Sarnat et al., 2008; Pope et al., 2002; Gwynn et al., 2000; Dockery et al., 1996; Raizenne et al., 1996).
PM mass is regulated and has been associated with adverse health endpoints in many studies (Laden et al., 2000; Pope et al., 2002, 2004; Metzger et al., 2004; Sarnat et al., 2008). Overall, water-soluble iron was highly correlated with PM mass (–0.80, Table S4), due to a correlation with sulfate (e.g., role of sulfate on aerosol pH). Interestingly, Fe was correlated with PM mass even in some cases when S did not co-vary with PM concentration. These cases are all in winter when the values between PM mass and S were 0.52, 0.35, 0.26, and 0.23, while those with Fe were 0.80, 0.75, 0.76, and 0.74 at JST (December), JST (March), GT (March), and RS (February), respectively. The exceptions were the two rural sites (YRK and CTR), where water-soluble Fe was moderately or not correlated with PM at all ( at YRK at CTR) while S and PM still had high correlations ( and 0.75 at YRK and CTR respectively).
Mn and Zn show some correlations with PM mass as well, but only during two periods (for Mn, at GT and 0.76 at RS, both in winter, for Zn, and 0.76 at JST in December and March, respectively). No significant correlations were ever found between PM and Cu. It has been demonstrated that water-soluble metals (Zn, Cu, and Fe) can have adverse effects on the respiratory system and our observations suggest that some water-soluble metals, especially Fe, are correlated with PM mass. However, some epidemiological studies point to organic carbon (Peel et al., 2005; Metzger et al., 2004) and PM mass (Sarnat et al., 2008; Pope et al., 2004; Metzger et al., 2004; Pope et al., 2002; Laden et al., 2000) but not metals. Li et al. (2009) suggests that redox-active organic chemicals could play major roles in PM toxicity and metals may synergize with organic PM components to further escalate oxidative stress. Thus, these water-soluble metals could play both dominant and important secondary roles in driving observed associations between fine particles and adverse health.
Conclusions
Over 500 PM filter samples (23hr integration time) were collected during 2012–2013 at multiple sites (three urban, two rural, one near-road site, and one road-side site) in the southeastern United States, using paired (simultaneous measurements at two different sites) high-volume samplers, as part of the Southeastern Center for Air Pollution & Epidemiology (SCAPE) project. A focus of SCAPE was assessing the role of PM associated reactive oxygen species (ROS) on health effects. Because water-soluble metals have been linked to ROS, a method was developed to measure the water-soluble elements (S, K, Ca, Ti, Mn, Fe, Cu, Zn, As, Se, Br, Sr, Ba, and Pb) on filters that were also analyzed for aerosol ROS activity by various assays (i.e., DTT and AA assays, discussed in other publications: Fang et al., 2015a, b; Verma et al., 2014). Water-soluble elements were determined by extracting filters in deionized water, re-aerosolizing the extracts and directing to an instrument designed for online measurements of aerosol elemental composition by non-destructive X-ray fluorescence. The system response was calibrated with standard solutions of multiple elements, which were also used as positive controls when running ambient samples to ensure stability and reproducibility (coefficient of variation %). The method LOD (limit of detection) for each element was reasonably low ( % of typical sample levels), and the overall uncertainties were less than 20 % for most elements, except for Cu, Sr, and Ti, with overall relative uncertainties of 25, 25, and 28 %, respectively. The method was further validated by comparing with sulfate measured by ion chromatography on the same ambient filter samples.
Water-soluble elements spanned a wide range of concentrations, from LODs (typically 0.1–30 ) to 1.2 , with S as the most abundant element, followed by Ca, K, Fe, Cu, Zn, and Ba. Positive matrix factorization (PMF) was used for source apportionment analyses. Four factors were identified: brake/tire wear, characterized by Ba, Zn, Cu, and Ti; biomass burning, characterized by K and Br; secondary formation, characterized by S, Se, Fe, and WSOC; and mineral dust, characterized by Ca, Mn, and Sr. Elements associated with secondary formation and mineral dust were higher during warm/dry seasons when aerosol re-suspension is favored (water-soluble Ca, Mn, and Sr) and secondary formation is high (water-soluble Fe and Cu). S and Se, products from coal combustion, were also at higher concentration in summer compared to winter. K had only slightly higher concentrations in winter due to contributions from biomass burning (mainly winter) and mineral dust emissions (mainly summer). Other elements (Zn, Ba, Br, Pb, Ti, and As) did not exhibit seasonal trends. Spatially, S, K, Ca, Mn, and Se were generally homogenously distributed, while Cu, Ba, Sr and Ti were more heterogeneously distributed, with highest levels near roadways. The other two urban sites outside of Georgia were heavily impacted by industrial sources, contributing to higher concentration of Zn, Mn, and Pb at Birmingham, AL (BHM), and Ca and Se at the East St. Louis, IL (ESL) site.
The redox-active metals, Cu, Mn, and Fe have been linked to ROS and oxidative stress. Among the four PMF factors, brake/tire wear contributed most to the water-soluble form of these elements in this study, with 51 % for Cu, 32 % for Fe, and 17 % for Mn, pointing to the importance of this source in contributing to fine particle ROS activity. Organic compounds from combustion also contribute to ROS activity, making overall vehicle emissions important sources of PM ROS.
Mn was associated mainly with mineral dust (45 %). Water-soluble Zn, a redox-inactive metal, but often identified as toxic in health studies, and among the highest in concentration in this study, was associated with a mixture of factors (45 % brake/tire wear, 26 % mineral dust, 14 % biomass burning, and 13 % secondary formation).
Roughly 50 % of water-soluble Fe was associated with the secondary formation factor, and was highly correlated with S (Pearson's r –0.76). There was also substantial loading of Cu (39 %) in this factor. Our previous studies in the southeast have linked water-soluble Fe (measured by a different technique) to sulfate, aerosol pH and soluble iron sulfates (Oakes et al., 2012). The association of Cu with this factor could also be due to increased solubility by sulfur-driven aerosol acidity. Of the four water-soluble metals (Cu, Mn, Fe, and Zn), only Fe was correlated with PM mass (r –0.80), due to its association with S. We have previously reported that ROS (DTT assay) measured on these same filters was correlated with PM mass (Fang et al., 2015a). These results indicate that additional aerosol components, such as redox-active organic compounds (Verma et al., 2015, 2014, 2012) also play a significant role in the ROS activity of aerosols in the southeastern USA, in addition to these water-soluble metals.
The Supplement related to this article is available online at
Acknowledgements
This publication was made possible by US EPA grant R834799. The contents are solely the responsibility of the grantee and do not necessarily represent the official views of the US EPA. Further, US EPA does not endorse the purchase of any commercial products or services mentioned in the publication. The authors thank Laura King for assistance in collecting samples, R. Erik Weber and Janessa Riana Rowland for assistance in lab work and the SEARCH personnel for their many contributions supporting the field deployments. T. Fang acknowledges the support from the Oversea Study Program of Guangzhou Elite Project. Edited by: F. Keutsch
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
© 2015. This work is published under http://creativecommons.org/licenses/by/3.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.
Abstract
Water-soluble redox-active metals are potentially toxic due to its ability to catalytically generate reactive oxygen species (ROS) in vivo, leading to oxidative stress. As part of the Southeastern Center for Air Pollution and Epidemiology (SCAPE), we developed a method to quantify water-soluble elements, including redox-active metals, from a large number of filter samples (
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Details


1 School of Earth and Atmospheric Sciences, Georgia Institute of Technology, Atlanta, GA, USA
2 School of Earth and Atmospheric Sciences, Georgia Institute of Technology, Atlanta, GA, USA; now at: Department of Civil and Environmental Engineering, University of Illinois Urbana-Champaign, Champaign, IL, USA
3 School of Public Health and Health Sciences, University of Massachusetts, Amherst, MA, USA