Abstract
Background
Setting the dry weight and maintaining fluid balance is still a difficult challenge in dialysis patients. Overhydration is common and associated with increased cardiac morbidity and mortality. Pulmonary hypertension is associated with volume overload in end-stage renal dysfunction patients. Thus, monitoring pulmonary pressure by a CardioMEMS device could potentially be of guidance to physicians in the difficult task of assessing fluid overload in hemodialysis patients.
Case presentation
61-year old male with known congestive heart failure deteriorated over 3 months’ time from a state with congestive heart failure and diuresis to a state of chronic kidney disease and anuria. He began a thrice/week in-hospital hemodialysis regime. As he already had implanted a CardioMEMS device due to his heart condition, we were able to monitor invasive pulmonary artery pressure during the course of dialysis sessions. To compare, we estimated overhydration by both bioimpedance and clinical assessment. Pulmonary artery pressure correlated closely with fluid drainage during dialysis and inter-dialytic weight gain. The patient reached prescribed dry weight but remained pulmonary hypertensive by definition. During two episodes of intradialytic systemic hypotension, the patient still had pulmonary hypertension by current definition.
Conclusion
This case report observes a close correlation between pulmonary artery pressure and fluid overload in a limited amount of observations. In this case we found pulmonary artery pressure to be more sensitive towards fluid overload than bioimpedance. The patient remained pulmonary hypertensive both as he reached prescribed dry weight and experienced intradialytic hypotensive symptoms. Monitoring pulmonary artery pressure via CardioMEMS could hold great potential as a real-time guidance for fluid balance during hemodialysis, though adjusted cut-off values for pulmonary pressure for anuric patients may be needed. Further studies are needed to confirm the findings of this case report and the applicability of pulmonary pressure in assessing optimal fluid balance.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer