Abstract
Background
This research aims to investigate the evaluation methods of teaching oral implant clinical courses and estimate the effectiveness of a virtual simulation platform.
Methods
Eighty second- and third-year undergraduates in Lanzhou University were recruited and randomized to either three experimental groups or one control group. The subjects undertook theoretical examinations to test their basic level of knowledge after training in similarly unified knowledge courses. Each student group then participated in an eight-hour operating training session. An operation test on pig mandible was conducted, followed by a second theoretical examination. The assessment consists of three distinct parts: a subjective operating score by a clinical senior teacher, an implant accuracy analysis in cone-beam computed tomography (angular, apical, and entrance deviation), and comparison of the two theoretical examinations. Finally, students completed a questionnaire gauging their understanding of the virtual simulation.
Results
There was no significant difference between the four groups in first theoretical examination (P > 0.05); the second theoretical scores of the V-J and J-V group (62.90 ± 3.70, 60.05 ± 2.73) were significantly higher than the first time (57.05 ± 3.92, P < 0.05), while no difference between the V (57.10 ± 3.66) and J (56.89 ± 2.67) groups was found. Thus, the combination of V-J was effective in improving students’ theoretical scores. The V-J and J-V groups had higher scores on operation (73.98 ± 4.58, 71.85 ± 4.67) and showed better implant precision.
Conclusion
Virtual simulation education, especially with a jaw simulation model, could improve students’ implantology achievements and training. Currently study found that the V-J group may performed better than the J-V group in oral implant teaching.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer