A curved image sensor on plastic foil has been developed for cone beam computed tomography (CBCT) X-ray imaging. The image sensor of about 6 × 8 cm2 size has been built on a thin polyimide foil with an indium gallium zinc oxide (IGZO) backplane and an organic photodetectors (OPD) frontplane. A flexible cesium iodide (CsI) scintillator has been attached to the optical sensor with 480 × 640 pixels of 126 µm size. Dark current density of the OPD was low with less than 10−7 mA/cm2 at −2 V, while an external quantum efficiency (EQE) of about 50% was reached in the visible wavelength range matched to the scintillator output. The image quality of the digital X-ray detector allowed for 3D reconstruction images of a bone phantom on a rotating stage with a lab setup. The curved detector with 32 cm curvature radius opens up the path for very compact CBCT gantries with largely reduced footprint.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Details



1 Holst Centre/TNO, Eindhoven, The Netherlands
2 Philips Research, Eindhoven, The Netherlands (GRID:grid.417284.c) (ISNI:0000 0004 0398 9387)
3 Philips Healthcare, Best, The Netherlands (GRID:grid.417284.c) (ISNI:0000 0004 0398 9387); Teledyne Dalsa, Eindhoven, The Netherlands (GRID:grid.417284.c)
4 Holst Centre/TNO, Eindhoven, The Netherlands (GRID:grid.417284.c)
5 Philips Healthcare, Best, The Netherlands (GRID:grid.417284.c) (ISNI:0000 0004 0398 9387)
6 imec, Leuven, Belgium (GRID:grid.15762.37) (ISNI:0000 0001 2215 0390)
7 Holst Centre/TNO, Eindhoven, The Netherlands (GRID:grid.15762.37); Technical University Eindhoven, Department of Applied Physics, Eindhoven, The Netherlands (GRID:grid.6852.9) (ISNI:0000 0004 0398 8763)