Full Text

Turn on search term navigation

© 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

(1) Background: The aim of the work is to identify some imaging parameters in osteogenesis imperfecta to assist the dentist in the diagnosis, planning, and orthodontic treatment of Osteogenesis Imperfecta (OI) using 3D cone beam Computed Tomography (CBCT) and the Double Energy X-ray Absorptiometry (DEXA) technique. (2) Methods: 14 patients (9 males and 5 females; aged mean ± SD 15 ± 1.5) with a clinical-radiological diagnosis of OI were analyzed and divided into mild and moderate to severe forms. The patients’ samples were compared with a control group of 14 patients (8 males and 6 females; aged mean ± SD 15 ± 1.7), free from osteoporotic pathologies. (3) Results: The statistical analysis allowed us to collect four datasets: in the first dataset (C1 sick population vs. C1 healthy population), the t-test showed a p-value < 0.0001; in the second dataset (C2 sick population vs. C2 healthy population), the t-test showed a p-value < 0.0001; in the third dataset (parameter X of the sick population vs. parameter X of the healthy population), the t-test showed a p-value < 0.0001; in the fourth dataset the bone mineralometry (BMD) value detected by the DEXA technique compared to the C2 value of the OI affected population only) the Welch–Satterthwaite test showed a p-value < 0.0001. (4) Conclusions: The research has produced specific imaging parameters that assist the dentist in making diagnostic decisions in OI patients. This study shows that patients with OI have a characteristic chin-bearing symphysis, thinned, and narrowed towards the center, configuring it with a constant “hourglass” appearance, not reported so far in the literature by any author.

Details

Title
New 3D Cone Beam CT Imaging Parameters to Assist the Dentist in Treating Patients with Osteogenesis Imperfecta
Author
Messineo, Daniela 1   VIAFID ORCID Logo  ; Luzzi, Valeria 2 ; Pepe, Francesca 2 ; Celli, Luca 3 ; Turchetti, Arianna 3 ; Zambrano, Anna 3 ; Celli, Mauro 3 ; Polimeni, Antonella 2   VIAFID ORCID Logo  ; Ierardo, Gaetano 2 

 Department of Radiological, Oncological and Anatomo-Pathological Sciences, Sapienza University of Rome, 00161 Rome, Italy 
 Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, 00161 Rome, Italy; [email protected] (V.L.); [email protected] (F.P.); [email protected] (A.P.); [email protected] (G.I.) 
 Rare Bone Metabolism Center, Pediatric Department, Sapienza University of Rome, 00161 Rome, Italy; [email protected] (L.C.); [email protected] (A.T.); [email protected] (A.Z.); [email protected] (M.C.) 
First page
546
Publication year
2020
Publication date
2020
Publisher
MDPI AG
e-ISSN
22279032
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2470095501
Copyright
© 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.