Abstract

Aims

Functional mitral regurgitation (MR) (FMR) is common in heart failure with reduced ejection fraction and worsens morbidity and mortality, even when mild. The CARILLON® mitral contour system (Cardiac Dimensions, Kirkland, WA, USA), a mitral annuloplasty device delivered percutaneously to the coronary sinus, is designed to reduce the mitral annular dimension by virtue of the close anatomic relationship between the coronary sinus and the posterior mitral annulus. We performed a comprehensive individual patient data meta‐analysis of all studies that used CARILLON® device vs. control that have measured mitral regurgitation severity, left ventricular (LV) remodelling, functional status, and heart failure‐related outcomes in heart failure with reduced ejection fraction patients.

Methods and results

The Cochrane Central Register of Controlled Trials, MEDLINE, and EMBASE were searched in July 2020. Primary outcomes of interest were measures of MR severity, LV remodelling, New York Heart Association functional class and heart failure‐related outcomes [mortality and heart failure hospitalization (HFH) during follow up]. All data were received as individual patient and individual time point data‐points. Mean differences and 95% confidence intervals (CIs) were calculated for continuous data using a fixed‐effects model. Three studies (REDUCE FMR, TITAN and TITAN II) enrolling 209 participants were identified and included. Pooled analysis showed that, compared with control, CARILLON® device significantly improved both MR volume (mean difference MD ‐9.20, 95% C.I. −16.11 to −2.29 mL, P = 0.009) and MR grade (MD ‐1.12, 95% CI −1.36 to −0.88, P < 0.00001) and this was associated with a significant reduction in LA volume, MD −7.54 mL, 95% CI −14.90 to − 0.18, P = 0.04. Significant LV reverse remodelling was also seen in terms of EDV (MD −16.53, 95% CI −28.61 to −44.4 mL, P = 0.007), and a trend in ESV (MD −8.68, 95% CI −18.69 to −1.34 mL, P = 0.09) but no significant effect on LVEF (MD 0.88, 95% CI −1.52% to 2.38%, P = 0.47), due presumably to the greater residual MR in the control patients falsely elevating the LVEF. In addition, the CARILLON® device significantly improved New York Heart Association functional Class (MD −0.22, 95% CI −0.24 to −0.16, P < 0.00001), associated with a lower rate of HFH compared with controls (45.3% vs. 64%, respectively, P = 0.04). As a sensitivity analysis we also restricted the analyses to those patients with Class 3+/4+ MR at baseline. In this cohort, the echocardiographic results were similar, and the reduction in HFH rates was even more marked (43.9% vs. 82.9%, respectively, P = 0.04).

Conclusions

This comprehensive meta‐analysis of individual patient data has shown that CARILLON® device provides statistically significant and clinically meaningful benefits on MR severity, LA and LV volumes, and remodelling and rates of subsequent heart failure hospitalization

Details

Title
Individual patient data meta‐analysis of the effects of the CARILLON® mitral contour system
Author
Giallauria, Francesco 1 ; Anna Di Lorenzo 2 ; Parlato, Alessandro 2 ; Testa, Crescenzo 2 ; Bobbio, Emanuele 3 ; Vigorito, Carlo 2 ; Stewart Coats, Andrew J 4 

 Department of Translational Medicine, ‘Federico II’ University of Naples, Naples, Italy; Faculty of Science and Technology, University of New England, Armidale, NSW, Australia 
 Department of Translational Medicine, ‘Federico II’ University of Naples, Naples, Italy 
 Department of Cardiology, Sahlgrenska University Hospital; Department of Molecular and Clinical Medicine, Institute of Medicine at Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden 
 University of Warwick, Coventry, UK 
Pages
3383-3391
Section
Original Research Articles
Publication year
2020
Publication date
Dec 2020
Publisher
John Wiley & Sons, Inc.
e-ISSN
20555822
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2471717663
Copyright
© 2020. This work is published under http://creativecommons.org/licenses/by-nc/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.