Abstract
Background
To compare the diagnostic accuracy of Doppler ultrasound (DUS) with contrast-enhanced ultrasound (CEUS) for detection of iliac vein stent stenosis using multidetector computed tomography venography (MDCTV) as the reference method.
Methods
Patients with iliac vein obstructive disease treated with nitinol stents (Smart Control, Cordis, USA) between January 2016 and December 2017 were consecutively included in this study. DUS, CEUS, and MDCTV were carried out in all patients within one week of each other at 1 year post stenting to investigate the presence of stent compression and in-stent restenosis (ISR).
Results
The study included 139 patients (87 females; mean age 58 ± 15 years). For detecting stent compression, the kappa coefficient between the ultrasound modality of gray-scale imaging and MDCTV was 0.901, indicating very good agreement between these two modalities. ISR was detected in 50, 61, and 65 patients by DUS, CEUS, and MDCTV, respectively. DUS and CEUS (kappa = 0.449) and DUS and MDCTV (kappa = 0.516) had moderate agreement for ISR diagnosis, while for which CEUS and MDCTV (kappa 0.884) had very good agreement. The sensitivity and specificity of DUS and CEUS for diagnosing ISR were 63.1% and 90.8%, 87.8% and 97.3%, respectively.
Conclusions
CEUS is probably superior to DUS in terms of diagnostic accuracy for the follow-up of patients with iliac vein stent stenosis.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer