It appears you don't have support to open PDFs in this web browser. To view this file, Open with your PDF reader
Abstract
Background
In our institute, all elderly patients with displaced femoral neck fracture were treated with cemented bipolar hemiarthroplasty (BHA) using the modified Dall approach. To our knowledge, there are no reports on the knot position of the greater trochanter reattachment. The aim of this study was to determine influence of two knot positions (anterior or posterior) on the complications of the greater trochanter.
Methods
This is a prospective non-randomized study conducted on 95 elderly patients (95 hips) from September 2013 to December 2017. The knot position was changed from anterior to posterior alternately. The X-ray images obtained immediately after the operation were compared with those obtained at 3 months postoperatively; thereafter, the status of the greater trochanter was classified into three types: type A, no apparent shifting and fracture; type C, over 1-mm shifting of the fragment; and type F, fracture of the greater trochanter.
Results
Regarding age at operation, sex, BMI, size of the greater trochanteric fragment, stem type, and surgeon, there was no significant difference between two groups. In the anterior group, 34 hips (72.3%), 5 hips (10.6%), and 8 hips (17.0%) were classified under type A, C, and F, respectively. In the posterior group, 44 hips (91.7%), 1 hip (2.1%), and 3 hips (6.3%) were classified under type A, C, and F, respectively. There were significantly fewer greater trochanteric complications in the posterior group.
Conclusions
The posterior knot position improved the union of the greater trochanter after BHA compared with the anterior knot position.
Trial registration
We had approved IRB at our hospital clinical research review committee. Retrospectively registered.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer