Backround
The study aim was to establish if substitution of citrate with rt-PA for catheter lock once weekly can reduce the incidence of catheter-related blood stream infections (CR-BSI) or improve patency of tunneled haemodialysis catheters.
Methods
All incident patients undergoing insertion of a tunneled haemodialysis catheter were screened and included except those suffering infection or using oral anticoagulation. Study participants were randomized into two arms according to the solution applied as catheter lock: receiving either trisodium citrate (Citra-LockTM 4%) only or rt-PA (Actilyse® 1 mg/ml) on the middle session each week with citrate used on the first and third sessions. The incidence of CR-BSI (confirmed by positive blood culture), catheter non-function (complete obstruction), and malfunction (blood flow < 250 ml/min) was recorded. Statistical significance was tested with ANOVA, post hoc analysis was performed by means of multiple linear regression.
Results
Totally, 18 patients were included and followed during 655 haemodialysis sessions. No episode of CR-BSI was detected while 6 catheter non-functions (0.9% sessions) and 101 malfunctions (15.4% sessions) were recorded. The incidence of both events was equal between the study arms: 4 non-functions and 55 malfunctions in the rt-PA arm and 2 non-functions and 46 malfunctions in the citrate arm (p = 0.47 and p = 0.24, respectively). Additionally, the mean blood flow achieved did not differ significantly between the arms: 326 ± 1,8 and 326 ± 1,9 ml/min (p = 0.95) in rt-PA and citrate arms, respectively. Post hoc analysis identified time elapsed since previous session (β = 0.12, p = 0.005) and malfunction on previous session (β = 0.25, p < 0.001) as significant factors affecting the occurrence of malfunction. By contrast, the study arm, rt-PA application on previous session, and catheter vintage did not enter the model.
Conclusion
Substitution of citrate with rt-PA for catheter lock does not reduce the incidence of catheter malfunction neither does it affect the blood flow achieved during haemodialysis. Catheter patency is related rather to the time interval between sessions and to previous malfunction (thus probably reflecting undefined individual factors). The incidence of CR-BSI within pre-selected haemodialysis population is sporadic (less than 1 per 4.3 patient years in our sample).
Trial registration
Australian New Zealand Clinical Trials Registry, ACTRN12612000152820. Retrospectively registered 03/02/2012.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer