Abstract
Echocardiographic assessment of systolic and diastolic function of the heart is often limited by image quality. However, the aortic root is well visualized in most patients. We hypothesize that the aortic root motion may correlate with the systolic and diastolic function of the left ventricle of the heart. Data obtained from 101 healthy volunteers (mean age 46.6 ± 12.4) was used in the study. The data contained sequences of standard two-dimensional (2D) echocardiographic B-mode (brightness mode, classical ultrasound grayscale presentation) images corresponding to single cardiac cycles. They also included sets of standard echocardiographic Doppler parameters of the left ventricular systolic and diastolic function. For each B-mode image sequence, the aortic root was tracked with use of a correlation tracking algorithm and systolic and diastolic values of traveled distances and velocities were determined. The aortic root motion parameters were correlated with the standard Doppler parameters used for the assessment of LV function. The aortic root diastolic distance (ARDD) mean value was 1.66 ± 0.26 cm and showed significant, moderate correlation (r up to 0.59, p < 0.0001) with selected left ventricular diastolic Doppler parameters. The aortic root maximal diastolic velocity (ARDV) was 10.8 ± 2.4 cm/s and also correlated (r up to 0.51, p < 0.0001) with some left ventricular diastolic Doppler parameters. The aortic root systolic distance (ARSD) was 1.63 ± 0.19 cm and showed no significant moderate correlation (all r values < 0.40). The aortic root maximal systolic velocity (ARSV) was 9.2 ± 1.6 cm/s and correlated in moderate range only with peak systolic velocity of medial mitral annulus (r = 0.44, p < 0.0001). Based on these results, we conclude, that in healthy subjects, aortic root motion parameters correlate significantly with established measurements of left ventricular function. Aortic root motion parameters can be especially useful in patients with low ultrasound image quality precluding usage of typical LV function parameters.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Details
1 Polish Academy of Sciences, Institute of Fundamental Technological Research, Warsaw, Poland (GRID:grid.413454.3) (ISNI:0000 0001 1958 0162)
2 Medical University of Warsaw, Department of Internal Medicine, Hypertension and Angiology, Warsaw, Poland (GRID:grid.13339.3b) (ISNI:0000000113287408)