Abstract
Introduction: Emergency department (ED) patients are frequently ventilated with excessively large tidal volumes for predicted body weight based on height, which has been linked to poorer patient outcomes. We hypothesized that supplying tape measures to respiratory therapists (RT) would improve measurement of actual patient height and adherence to a lung-protective ventilation strategy in an ED-intensive care unit (ICU) environment.
Methods: On January 14, 2019, as part of a ventilator-associated pneumonia prevention bundle in our ED-based ICU, we began providing RTs with tape measures and created a best practice advisory reminding them to record patient height. We then retrospectively collected data on patient height and tidal volumes before and after the intervention.
Results: We evaluated 51,404 tidal volume measurements in 1,826 patients over the 4 year study period; of these patients, 1,579 (86.5%) were pre-intervention and 247 (13.5%) were post-intervention. The intervention was associated with a odds of the patient’s height being measured were 10 times higher post-intervention (25.1% vs 3.2%, P <0.05). After the bundle was initiated, we observed a significantly higher percentage of patients ventilated with mean tidal volumes less than 8 cubic centimeters per kilogram (93.9% vs 84.5% P < 0.05).
Conclusion: Patients in an ED-ICU environment were ventilated with a lung-protective strategy more frequently after an intervention reminding RTs to measure actual patient height and providing a tape measure to do so. A significantly higher percentage of patients had height measured rather than estimated after the intervention, allowing for more accurate determination of ideal body weight and calculation of lung-protective ventilation volumes. Measuring all mechanically ventilated patients’ height with a tape measure is an example of a simple, low-cost, scalable intervention in line with guidelines developed to improve the quality of care delivered to critically ill ED patients.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer