Abstract
Background
How to perform minimally-invasive surgery on Tile C pelvic fractures is very difficult, and it is also a hot topic in orthopedic trauma research. We applied minimally-invasive treatment using an anterior internal fixator combined with sacroiliac screws.
Objectives
To compare the biomechanical properties of different fixation models in pelvic facture specimens, using an internal fixation system or a steel plate combined with sacroiliac screws.
Methods
Sixteen fresh adult cadaver pelvic specimens were randomly separated into four groups named A, B, C, and D. The four groups were respectively stabilized using a two-screwed, three-screwed, or four-screwed anterior internal fixator or a steel plate with sacroiliac screws. All models were tested in both standing and sitting positions. Vertical loads of 600 N were applied increasingly. Shifts of bilateral sacroiliac joints and pubis rupture were measured.
Results
The shifts in sacroiliac joints and pubis rupture in the standing position were all less than 3.5 mm, and the shifts in the sitting position were all less than 1 mm. In the standing position, the results of shifts in the sacroiliac joints were group C < group D < group B < group A. For comparisons between A:B and C:D, P > 0.05. For comparisons between A, B:C, and D, P < 0.05. The results of shifts in pubis ruptures were group D < group C < group B < group A. In the comparison between C:D, P > 0.05; for comparisons between A:B, A:C, A:D, B:C, and B:D, P < 0.05. In the sitting posture, the results of shifts in the sacroiliac joints were group C < group D < group B < group A, and the shifts in the pubis ruptures were group D < group C < roup B < group A. For comparison between C:D, P > 0.05. For comparisons between A:B, A:C, A:D, B:C, and B:D, P < 0.05.
Conclusion
Use of an anterior internal fixator combined with sacroiliac screws effectively stabilized Tile C3 pelvic fractures. The stability of specimens increased as the number of screws in the internal fixator increased.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer