Abstract
Background
To evaluate the early prognosis and management of acute coronary involvement (ACI) in type A aortic dissection (ATAAD) patients without myocardial ischemia (MI).
Methods
We conducted a retrospective cohort study on a multicenter database. A total of 931 ATAAD patients without MI underwent thoracic aortic surgery between 2018 and 2019 in the Acute Aortic Syndrome Cooperation Network (AASCN) and were enrolled in our study. Patients were divided into two groups: ACI group and non-ACI group.
Results
There were 139 ACI patients (14.9%) and 792 non-ACI patients (85.1%) in our cohort. ACI group had higher 30-day mortality after surgery than non-ACI group (log-rank test: P = 0.028,Cox regression: hazard ratio [HR], 2.3; 95% confidence interval [95% CI], 1.1–5.39; P = 0.047), especially in sub-group of advanced age (53–80 years; HR, 4.0; 95% CI, 1.3–12.8; P = 0.017), low diastolic blood pressure (29-69 mmHg, HR, 3.8; 95% CI, 1.3–11.2; P = 0.018), low systolic blood pressure (51–119 mmHg, HR, 3.6; 95% CI, 1.1–12.4; P = 0.040), high body mass index (BMI;27.25–47.52 kg/m2; HR, 3.7; 95% CI, 1.3–10.7; P = 0.015) and high hemoglobin (>145 g/L; HR, 4.3; 95% CI, 1.2–16.0; P = 0.030). Acute renal failure was significant more in ACI group than non-ACI group (24.5% vs. 15.9%; P = 0.014).
Conclusions
ACI increases the short-term postoperative mortality and acute renal failure in ATAAD patients without MI. ATAAD patients with ACI may need a narrower control range of blood pressure even if without myocardial ischemia.
Trial registration
ChiCTR1900022637. Retrospectively registered 19 April 2019.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer