It appears you don't have support to open PDFs in this web browser. To view this file, Open with your PDF reader
Abstract
Background
Assessing the accuracy of diagnostic coding is essential to ensure the validity and reliability of administrative coded data. The aim of the study was to evaluate the accuracy of assigned International Classification of Diseases version 10-Australian Modification (ICD-10-AM) codes for influenza by comparing with patients’ results of their polymerase chain reaction (PCR)-based laboratory tests.
Method
A retrospective study was conducted across seven public hospitals in New South Wales, Australia. A total of 16,439 patients who were admitted and tested by either cartridge-based rapid PCR or batched multiplex PCR between January 2016 and December 2017 met the inclusion criteria. We calculated the sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of ICD-10-AM coding using laboratory results as a gold standard. Separate analyses were conducted to determine whether the availability of test results at the time of hospital discharge influenced diagnostic coding accuracy.
Results
Laboratory results revealed 2759 positive influenza cases, while ICD-10-AM coding identified 2527 patients. Overall, 13.7% (n = 378) of test positive patients were not assigned an ICD-10-AM code for influenza. A further 5.8% (n = 146) patients with negative test results were incorrectly assigned an ICD-10-AM code for influenza. The sensitivity, specificity, PPV and NPV of ICD-10-AM coding were 93.1%; 98.9%; 94.5% and 98.6% respectively when test results were received before discharge and 32.7%; 99.2%; 87.8% and 89.8% respectively when test results were not available at discharge. The sensitivity of ICD-10-AM coding varied significantly across hospitals. The use of rapid PCR or hospitalisation during the influenza season were associated with greater coding accuracy.
Conclusion
Although ICD-10-AM coding for influenza demonstrated high accuracy when laboratory results were received before discharge, its sensitivity was substantially lower for patients whose test results were not available at discharge. The timely availability of laboratory test results during the episode of care could contribute to improved coding accuracy.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer