Full text

Turn on search term navigation

© 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Measured variability of product within Cell and Gene Therapy (CGT) manufacturing arises from numerous sources across pre-analytical to post-analytical phases of testing. Operators are a function of the manufacturing process and are an important source of variability as a result of personal differences impacted by numerous factors. This research uses measurement uncertainty in comparison to Coefficient of Variation to quantify variation of participants when they complete Flow Cytometry data analysis through a 5-step gating sequence. Two study stages captured participants applying gates using their own judgement, and then following a diagrammatical protocol, respectively. Measurement uncertainty was quantified for each participant (and analysis phase) by following Guide to the Expression of Uncertainty in Measurement protocols, combining their standard deviations in quadrature from each gating step in the respective protocols. When participants followed a diagrammatical protocol, variation between participants reduced by 57%, increasing confidence in a more uniform reported cell count percentage. Measurement uncertainty provided greater resolution to the analysis processes, identifying that most variability contributed in the Flow Cytometry gating process is from the very first gate, where isolating target cells from dead or dying cells is required. This work has demonstrated the potential for greater usage of measurement uncertainty within CGT manufacturing scenarios, due to the resolution it provides for root cause analysis and continuous improvement.

Details

Title
Assessment of Protocol Impact on Subjectivity Uncertainty When Analyzing Peripheral Blood Mononuclear Cell Flow Cytometry Data Files
Author
Grant, Rebecca 1   VIAFID ORCID Logo  ; Coopman, Karen 2 ; Silva-Gomes, Sandro 3 ; Campbell, Jonathan J 4 ; Kara, Bo 3 ; Braybrook, Julian 4 ; Petzing, Jon 1   VIAFID ORCID Logo 

 Wolfson School of Mechanical, Electrical and Manufacturing Engineering, Loughborough University, Loughborough, Leicestershire LE11 3TU, UK; [email protected] 
 Department of Aeronautical, Automotive, Chemical and Materials Engineering, Loughborough University, Loughborough, Leicestershire LE11 3TU, UK; [email protected] 
 GlaxoSmithKline, Gunnels Wood Road, Stevenage SG1 2NY, UK; [email protected] (S.S.-G.); [email protected] (B.K.) 
 LGC Group, Queen’s Road, Teddington, Middlesex TW11 0LY, UK; [email protected] (J.J.C.); [email protected] (J.B.) 
First page
24
Publication year
2021
Publication date
2021
Publisher
MDPI AG
e-ISSN
24099279
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2544523038
Copyright
© 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.