Full Text

Turn on search term navigation

© 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

A single-visit zirconia restoration can be easily achieved if direct milling of a fully sintered zirconia block can be performed without much effort. However, no studies have yet been reported regarding the evaluation of the trueness of crown fabricated from chairside-milling of a fully sintered zirconia block in the chairside computer-aided design and computer-aided manufacturing (CAD–CAM) system for single-visit dentistry. This in vitro study aimed to evaluate the trueness of crowns fabricated by milling a fully sintered zirconia block in the chairside CAD–CAM system and investigate the clinical implications for single-visit chairside restoration. Crowns were fabricated either by chairside-milling a fully sintered block of niobium oxide containing yttria-stabilized tetragonal zirconia polycrystals ((Y, Nb)-TZP) without the sintering process (n = 12) in a chairside single-visit dentistry system (Chairside group) or by laboratory-milling a partially sintered 3 mol% block of yttria-stabilized tetragonal zirconia polycrystals (3Y-TZP) followed by the sintering process (n = 12) in a conventional laboratory system (Labside group). Crown fabrication time, milling tool diameter and the trueness of each crown were evaluated. All trueness values of both groups were within the clinically acceptable range, although a significant difference between the Chairside (43.0 ± 3.67 μm) and Labside groups (37.4 ± 2.41 μm) was observed (P < 0.05). Mean fabrication time was 0.52 h and 1.42 h for Chairside and Labside groups, respectively. A decrease in the tool diameter was observed for the Chairside group.

Details

Title
Trueness of the Inner Surface of Monolithic Crowns Fabricated by Milling of a Fully Sintered (Y, Nb)-TZP Block in Chairside CAD–CAM System for Single-visit Dentistry
Author
Jun-Ho, Cho 1 ; Yoon, Hyung-In 1   VIAFID ORCID Logo  ; Jung-Suk, Han 1 ; Dae-Joon, Kim 2 

 Department of Prosthodontics, School of Dentistry and Dental Research Institute, Seoul National University, Seoul 03080, Korea; [email protected] (J.-H.C.); [email protected] (J.-S.H.) 
 Department of Dentistry, School of Dentistry and Dental Research Institute, Seoul National University, Seoul 03080, Korea; [email protected] 
First page
3253
Publication year
2019
Publication date
2019
Publisher
MDPI AG
e-ISSN
19961944
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2548710333
Copyright
© 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.