Abstract

Background

Skin necrosis and implant exposure most often appear at the corner of Extensile Lateral Approach for open reduction and internal fixation (ORIF) for displaced intra-articular fracture of the calcaneus. Flap transfer is often used for coverage of this implant exposure. We introduced a new simple local random pattern flap to cover the implant exposure.

Methods

From March 2017 to March 2020, 12 patients with implant exposure after ORIF for displaced intra-articular fracture of the calcaneus were treated with this procedure. The sizes of the defects ranged from 2 × 2 cm2 to 5 × 2 cm2. A local random pattern flap was designed according to the defect size. The lower edge of the flap was along with the wound upper edge and extended distally. The upper horizontal incision of the flap was made at the lateral malleolus level with a length of 5–7 cm depending on the wound defect. Then the random pattern flap was elevated and transferred to cover the defect area.

Results

The mean follow-up duration was 6.3 months (ranging 4–13 months). All 12 flaps were uneventfully healed and all patients were able to wear shoes, and no debulking procedures were required.

Conclusion

The local random pattern flap could be a choice for surgeons when implant exposure at the corner of Extensile Lateral Approach to the Calcaneus occurs.

Details

Title
Local Random Pattern Flap Coverage for Implant Exposure following Open Reduction Internal Fixation via Extensile Lateral Approach to the Calcaneus
Author
Liu, Yingjie; Cai, Peihua; Cheng, Liang; Li, Yanfeng
Pages
1-5
Section
Research
Publication year
2021
Publication date
2021
Publisher
BioMed Central
e-ISSN
14712474
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2552824150
Copyright
© 2021. This work is licensed under http://creativecommons.org/licenses/by/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.