Full text

Turn on search term navigation

© 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Peri-implant bone density plays an important role in the osseointegration of dental implants. The aim of the study was to evaluate via micro-CT, in Hounsfield units, the bone density around dental implants coated with chitosan and melatonin and to compare it with the bone density around implants with a conventional etched surface after 12 weeks of immediate post-extraction placement in the jaws of Beagle dogs. Six dogs were used, and 48 implants were randomly placed: three groups—melatonin, chitosan, and control. Seven 10 mm × 10 mm regions of interest were defined in each implant (2 in the crestal zone, 4 in the medial zone, and 1 in the apical zone). A total of 336 sites were studied with the AMIDE tool, using the Norton and Gamble classification to assess bone density. The effect on bone density of surface coating variables (chitosan, melatonin, and control) at the crestal, medial, and apical sites and the implant positions (P2, P3, P4, and M1) was analyzed at bivariate and multivariate levels (linear regression). Adjusted effects on bone density did not indicate statistical significance for surface coatings (p = 0.653) but did for different levels of ROIs (p < 0.001) and for positions of the implants (p = 0.032). Micro-CT, with appropriate software, proved to be a powerful tool for measuring osseointegration.

Details

Title
Bone Density around Titanium Dental Implants Coating Tested/Coated with Chitosan or Melatonin: An Evaluation via Microtomography in Jaws of Beagle Dogs
Author
López-Valverde, Nansi 1   VIAFID ORCID Logo  ; López-Valverde, Antonio 1   VIAFID ORCID Logo  ; Aragoneses, Juan Manuel 2   VIAFID ORCID Logo  ; Martínez-Martínez, Francisco 3   VIAFID ORCID Logo  ; González-Escudero, María C 4 ; Ramírez, Juan Manuel 5 

 Department of Surgery, Instituto de Investigación Biomédica de Salamanca (IBSAL), University of Salamanca, 37007 Salamanca, Spain; [email protected] 
 Dean of The Faculty of Dentistry, Universidad Alfonso X El Sabio, 28691 Madrid, Spain; [email protected] 
 Orthopaedic and Trauma Service, Virgen de la Arrixaca University Hospital, El Palmar, 30120 Murcia, Spain; [email protected] 
 Faculty of Health Sciences, Universidad Católica San Antonio de Murcia (UCAM), 30107 Murcia, Spain; [email protected] 
 Department of Morphological Sciences, University of Cordoba, Avenida Menéndez Pidal s/n, 14071, 14004 Cordoba, Spain; [email protected] 
First page
777
Publication year
2021
Publication date
2021
Publisher
MDPI AG
e-ISSN
20796412
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2554481427
Copyright
© 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.