It appears you don't have support to open PDFs in this web browser. To view this file, Open with your PDF reader
Abstract
This paper presents the mechanical properties of porous asphalt (PA) with nanosilica (NS) modified asphalt binder in terms of its Moisture Susceptibility. This test is essential to evaluate the performance of NS-PA towards the resistance of moisture induced damage. Moisture susceptibility can be defined as the loss durability, strength and stiffness of PA due to the existence of moisture, causing the adhesive loss of binder and aggregate. It is interesting to know that the existence of nanoparticle with different proportion can affect the moisture susceptibility behavior of NS-PA. Three different percentages of nanosilica were mixed with PEN 60-70 type of binder in this study. Then, all these blended modified binder were used to prepare PA Grading B specimens using Marshall Mix Design Method. Nanoparticle used in this study was Nanosilica with the average size of 10 to 15 nanometer. In addition, Moisture Susceptibility of NS-PA was evaluated using Indirect Tensile Strength Test, based on Modified Lottman Test. From the result, the maximum TSR value obtained at 2% NS-PA, which was 91%. Meanwhile, for conventional PA (0% NS), TSR value was only 74%. In accordance to AASTHOT283, TSR value should be equal or more than 80% to withstand moisture induced damage. However, for PA, 70% TSR value is consider acceptable due to porous nature of PA that permit water to flow inside the mix. From this result, it was concluded that the optimum amount of NS required for PA to withstand moisture induced damage was 2%. Thus, with proper NS concentration, the performance of PA with NS modified binder in terms of moisture susceptibility can be enhanced.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Details
1 Faculty of Civil Engineering & Earth Resources, Universiti Malaysia Pahang, Pahang, Malaysia.
2 Institute for Infrastructure Engineering & Sustainable Management, Universiti Teknologi MARA, Shah Alam, Selangor, Malaysia.