Abstract
The cryocooler technology is advancing in different ways at a considerable pace to explore cooler applications in diversified field. Stirling cryocoolers are capable to satisfy the contemporary requirements of a low-capacity cooler. A compact mechanism that can drive Stirling cryocooler with larger stroke and thus enhance the cooler performance is the need of the hour. The increase in the stroke will lead to a higher volumetric efficiency. Hence, a cryocooler with larger stroke will experience higher mass flow rate of the working fluid, thereby increasing its ideal cooling capacity. The novel compact drive mechanism that fulfils this need is a promising option in this regards. It is capable of operating more than one cryocoolers of different Stirling configurations simultaneously. This arrangement makes it possible to compare different Stirling cryocoolers on the basis of pressure ratio obtained experimentally. The preliminary experimental results obtained in this regard are presented here. The initial experimentation is carried out on two Alpha Stirling units driven simultaneously by the novel compact mechanism. The pressure ratio obtained during the initial stages is 1.3538, which is enhanced to 1.417 by connecting the rear volumes of the compressor pistons to each other. The fact that annular leak across the expander pistons due to high pressure ratio affects the cryocooler performance, generates the need to separate the expansion space from bounce space. This introduces a Gamma configuration that is operated simultaneously with one of the existing Alpha units by same drive mechanism and having identical compression space volume. The results obtained for pressure ratio in both these units prove the concept that cooling capacity of Alpha configuration exceeds that of Gamma under similar operating conditions. This has been observed at 14 bar and 20 bar charge pressures during the preliminary experimentation. These results are presented in this paper. Thus, the theoretical predictions regarding pressure ratio and hence the cooling capacity of Alpha and Gamma configurations for low-capacity units are confirmed experimentally in the present work.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Details
1 Department of Mechanical Engineering, IIT Bombay, Mumbai - 400 076, India; Department of Mechanical Engineering, Vishwakarma Institute of Technology, Pune 411 037, India
2 Department of Mechanical Engineering, IIT Bombay, Mumbai - 400 076, India