It appears you don't have support to open PDFs in this web browser. To view this file, Open with your PDF reader
Abstract
Joints between copper and stainless steel are commonly applied in cryogenic systems. A relatively new and increasingly important method to combine these materials is electron-beam (EB) welding. Typically, welds in cryogenic applications need to withstand a temperature range from 300K down to 4K, and pressures of several MPa. However, few data are available for classifying EB welds between OFHC copper and 316L stainless steel. A broad test program was conducted in order to qualify this kind of weld. The experiments started with the measurement of the hardness in the weld area. To verify the leak-tightness of the joints, integral helium leak tests at operating pressures of 16 MPa were carried out at room- and at liquid nitrogen temperature. The tests were followed by destructive tensile tests at room temperature, at liquid nitrogen and at liquid helium temperatures, yielding information on the yield strength and the ultimate tensile strength of the welds at these temperatures. Moreover, nondestructive tensile tests up to the yield strength, i.e. the range in which the weld can be stressed during operation, were performed. Also, the behavior of the weld upon temperature fluctuations between room- and liquid nitrogen temperature was tested. The results of the qualification indicate that EB welded joints between OFHC copper and 316L stainless steel are reliable and present an interesting alternative to other technologies such as vacuum brazing or friction welding.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Details
1 Karlsruhe Institute of Technology, Institute for Technical Physics, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany; Karlsruhe Institute of Technology, Institute for Technical Thermodynamics and Refrigeration, Kaiserstrasse 12, 76131 Karlsruhe, Germany
2 WEKA AG, Schürlistrasse 8, 8344 Bäretswil, Switzerland
3 Karlsruhe Institute of Technology, Institute for Technical Physics, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany