Abstract
Platinum nanodendrites (PtNDs) are high-Z nanomaterials (Z=78) that possess a promising potential to be introduced as a novel contrast agent in diagnostic radiology. The objective of this study is to investigate the performance of PtNDs as contrast agent in computed tomography in term of CT number and CNR. PtNDs of different sizes (29, 36, 42, 52 nm) were prepared into final concentration of 1.0 mM in 3 mL syringes. CT scans were performed on PtND samples, distilled water and iodinated contrast agent arranged in phantom. The scans of each samples were conducted at 0.6 mm slice thickness and 80 kVp setting. CT number and contrast to noise ratio (CNR) were measured and calculated. The attenuation property of PtNDs shows size dependent characteristics, as the smallest PtNDs tested (29 nm) shows the lowest CT number (3.73 ± 0.37), followed by 36 nm PtNDs (21.23 ± 0.77), 42 nm (62.77 ± 2.08) and 52 nm (89.33 ± 4.60). CNR quantification reveals that there are no significant different of CNR values for PtNDs of size 29 nm, 36 nm, and 42 nm (around 24.67 ± 0.25), while 52 nm PtNDs sees drop of CNR (20.14 ± 0.57). Compared to iodinated contrast agent, 42 and 52 nm PtNDs show higher CT number, with slightly reduced CNR. This preliminary study suggests that PtNDs have the potential to be applied as contrast agents for CT imaging. The study also demonstrates that the performance of nanomaterial based contrast agent and x-ray attenuation properties are dependent on nanoparticles size and further study is required to elucidate multiparameter involved.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Details
1 School of Health Sciences, Health Campus, Universiti Sains Malaysia, 16150 Kubang Kerian, Kelantan, Malaysia
2 School of Material and Mineral Resources Engineering, Engineering Campus, Universiti Sains Malaysia, 14300 Nibong Tebal, Penang, Malaysia.