Abstract
In this work, the results of a numerical code based on the porous media Local Thermal Non-Equilibrium (LTNE) and the apparent heat capacity methods, are compared with experiments aiming at a preliminary validation. The test cell consists in a 50 mm aluminum foam cube filled with a paraffin wax, heated and cooled on the same face. The heat flux is measured by two miniaturized sensors, while the temperature is measured in three different locations along the cube edge. Finally, one side is equipped with a Zinc Selenide window which is transparent to the long wave InfraRed. This system allows to track the paraffin melting front evolution together with the temporal trend of the whole temperature distribution simplifying the comparison with the numerical outputs at different time steps.
The numerical model is then set with the same boundary conditions (heat flux) to predict the experimental temperature fields, considering both conduction in the solid domain and natural convection in the liquid domain. The preliminary validation shows that the numerical results match the experimental data with good agreement. Results are also presented for different gravity levels. This study can be a starting point for all those applications where gravity has a major role.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Details
1 Dipartimento di Ingegneria Industriale - Università degli Studi di Napoli Federico II - Piazzale Tecchio, 80 - 80125 – Napoli Italy
2 Dipartimento dell’Energia dei Sistemi del Territorio e delle Costruzioni - Università di Pisa – Largo Lazzarino, 2 - 56121 – Pisa Italy