Full Text

Turn on search term navigation

© 2021 Li et al. This is an open access article distributed under the terms of the Creative Commons Attribution License: http://creativecommons.org/licenses/by/4.0/ (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Background

Caudal epidural block (CEB) provides reliable anesthesia for adults undergoing anorectal surgery. Despite the widely utilization, the minimum effective concentration for 90% patients (MEC90) of ropivacaine for CEB remains unknown.

Objective

To estimate MEC of ropivacaine for CEB in anorectal surgery.

Design

A prospective dose-finding study using biased coin design up-and-down sequential method.

Setting

Operating room and postoperative recovery area of Chengdu Shangjin Nanfu Hospital, from October 2019 to January 2020.

Patients

50 males and 51 females scheduled for anorectal surgery.

Interventions

We conducted two independent biased coin design up-and down trials by genders. The concentration of ropivacaine administered to the first patient of male and female were 0.25% with fixed volume of 14ml for male and 12ml for female patients based on our previous study. In case of failure, the concentration was increased by 0.05% in the next subject. Otherwise, the next subject was randomized to a concentration 0.05% less with a probability of 0.11, or the same concentration with a probability of 0.89. Success was defined as complete sensory blockade of perineal area 15 min after the block evidenced by the presence of a lax anal sphincter and pain-free surgery.

Main outcome measures

The MEC of ropivacaine to achieve a successful CEB in 90%(MEC90) of the patients.

Results

The MEC90 of ropivacaine for CEB were estimated to be 0.35% (95% CI 0.29 to 0.4%) for male and 0.353% (95%CI 0.22 to 0.4%) for female. By extrapolation to MEC in 99% of subjects (MEC99) and pooled adjacent violators algorithm (PAVA) adjusted responses, it would be optimal to choose 0.4% ropivacaine with a volume of 14ml for male and 12ml for female.

Conclusions

A concentration of 0.35% ropivacaine with a volume of 14ml provided a successful CEB in 90% of the male patients, while 0.353% ropivacaine with a volume of 12ml provided a successful CEB in 90% of the female patients. A concentration of 0.4% and a volume of 14ml for male and 12 ml for female would be successful in 99% of the patients.

Trial registration

Chictr.org.cn identifier: No. ChiCTR 1900024315.

Details

Title
The minimum effective concentration (MEC90) of ropivacaine for ultrasound-guided caudal block in anorectal surgery. A dose finding study
Author
Li, Xuehan; Li, Jun; Zhang, Pei; Deng, Huifei; Yang, Mingan; He, Hongbo; Wang, Rurong
First page
e0257283
Section
Research Article
Publication year
2021
Publication date
Sep 2021
Publisher
Public Library of Science
e-ISSN
19326203
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2573822279
Copyright
© 2021 Li et al. This is an open access article distributed under the terms of the Creative Commons Attribution License: http://creativecommons.org/licenses/by/4.0/ (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.