© 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Since a concrete structure exposed to a sulfate environment is subject to surface ion ingress that yields cracking due to concrete swelling, its service life evaluation with an engineering modeling is very important. In this paper, cementitious repair materials containing bacteria, Rhodobacter capsulatus, and porous spores for immobilization were developed, and the service life of RC (Reinforced Concrete) structures with a developed bacteria-coating was evaluated through deterministic and probabilistic methods. Design parameters such protective coating thickness, diffusion coefficient, surface roughness, and exterior sulfate ion concentration were considered, and the service life was evaluated with the changing mean and coefficient of variation (COV) of each factor. From service life evaluation, more conservative results were evaluated with the probabilistic method than the deterministic method, and as a result of the analysis, coating thickness and surface roughness were derived as key design parameters for ensuring service life. In an environment exposed to an exterior sulfate concentration of 200 ppm, using the deterministic method, the service life was 17.3 years without repair, 19.7 years with normal repair mortar, and 29.6 years with the application of bacteria-coating. Additionally, when the probabilistic method is applied in the same environment, the service life was changed to 9.2–16.0 years, 10.5–18.2 years, and 15.4–27.4 years, respectively, depending on the variation of design parameters. The developed bacteria-coating technique showed a 1.47–1.50 times higher service life than the application of normal repair mortar, and the effect was much improved when it had a low COV of around 0.1.

Details

Title
Service Life Evaluation for RC Sewer Structure Repaired with Bacteria Mixed Coating: Through Probabilistic and Deterministic Method
Author
Yoon, Hyun-Sub 1   VIAFID ORCID Logo  ; Yang, Keun-Hyeok 1   VIAFID ORCID Logo  ; Lee, Kwang-Myong 2 ; Seung-Jun Kwon 3   VIAFID ORCID Logo 

 Department of Architectural Engineering, Kyonggi University, Suwon 16227, Korea; [email protected] (H.-S.Y.); [email protected] (K.-H.Y.) 
 Department of Civil, Architectural and Environmental System Engineering, Sungkyunkwan University, Suwon 16419, Korea; [email protected] 
 Department of Civil and Environmental Engineering, Hannam University, Daejeon 34430, Korea 
First page
5424
Publication year
2021
Publication date
2021
Publisher
MDPI AG
e-ISSN
19961944
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2576470317
Copyright
© 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.