This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
1. Introduction
Solar thermal systems such as solar crop dryers, solar thermal cookers, and water and air heaters make use of collectors. Solar collectors are heat exchangers that change solar radiation into the internal heat of transport media in solar thermal systems for practical and useful purposes. However, recent studies including this one have established that unglazed solar thermal systems experience wind-induced convective heat transfer losses due to their external exposures to their immediate surroundings [1, 2].
Topmost surface heat loss and heat exchange with adjacent fluids influence the overall thermal performance of solar collector systems. The importance of studying this wind-induced convective heat loss that occurs in unglazed solar thermal systems is that it has a direct effect on the thermal efficiency of solar collector systems [3, 4]. The heat transfer coefficient
The value of
The concept of
The novelty of this work is the use of an experiment to develop convective heat transfer coefficients for Ghana and to produce representative equations for determining the heat transfer coefficient for solar plate collectors in unsteady humid outdoor conditions in West Africa. This work intends to contribute data alongside similar works done for different areas or regions with the aim of developing empirical equations that can be combined to generate standard equations for determining global and not site-specific heat transfer coefficients in the future.
The volume of work done in this area of research is an indication of how relevant, interesting, and broad this study area is. It is for this reason that this paper has been produced to reveal another area of interest in solar technology experiments. This study specifically estimates the heat transfer coefficient of an unglazed solar plate for unsteady humid outdoor condition; and introduces and as well makes significant contribution in this area of research. This paper comes after numerous previous works including the work done by [5, 9, 10] which established a functional convective heat transfer model,
[5] conducted an experiment with two different layered materials between a top aluminium plate and a bottom thermocole slab (insulator) to determine the heat transfer coefficient as the sun races through the arranged materials. During the experiment, values were taken at a time interval of 1 s for two years on a
[9] also conducted an experiment to investigate the influence of size on heat transfer coefficient,
[10] also did an experiment over a roof top to estimate the heat transfer coefficient. The studio was placed outside with layered construction materials held together in a wooden case. The first layer is a 2 mm aluminium sheet with a
This research has established the need to develop a heat transfer coefficient empirical model for each and every geographical area since both analytical and numerical models launched by several authors could not eliminate or erode the infringements in the estimation of the heat transfer coefficient. This deficiency is investigated by this study, and the authors of this research really recommend the comprehensive investigation of this phenomenon by future studies. It has also been established by this study that a seemingly similar equation was used by previous works to estimate the heat transfer coefficient in outdoor conditions even though outdoor heat transfer coefficients are site-specific. For this reason, this study is proposing the use of different appropriate models for determining heat transfer coefficients for Ghana specifically Sunyani as the performance of thermal systems depends on local conditions such as solar irradiation, rainfall, and localized wind-induced convection.
2. Materials and Methods
This section talks about the experimental setup, validated data, and the development of a model as well as comparing the developed model to previous works.
2.1. Heat Transfer Models
There are several linear regressions introduced in Introduction which are used as a benchmark for validating data and comparing the model produced by this research. The models are represented in Table 1 and the environment in which they were performed. The differences in these models are due to the prevailing experimental conditions. These models are normalised to make it comparable to the new model produced by this study as stated in Introduction.
Table 1
Models developed by previous works.
S/N | Model | Reference | Setup/studio |
1 | [11] | Indoor | |
2 | [12] | Indoor | |
3 | [4] | Outdoor | |
4 | [3] | Indoor | |
5 | [10] | Outdoor |
2.2. Method
This section describes the experimental setup used to evaluate the heat transfer coefficient for a horizontal flat plate solar collector under environmental conditions in the University of Energy and Natural Resources, Sunyani campus. The experimental setup involves three major materials, namely, mild steel plate, asbestos board, and plywood. The arrangement is shown in Figure 1. The mild steel plate is of a thickness of 0.1 cm whereas the asbestos board is produced to a thickness of 2 cm. The plywood (100 cm thick) was used to insulate the whole setup (
[figures omitted; refer to PDF]
The experiment was performed from March to August, 2020, in Sunyani, the regional capital of the Bono Region of Ghana. The period for this research begins from the hottest month and spans the most raining months (April-July) established in Ghana to August thus exposing this experiment to a considerable amount of humidity. To avoid the possibility of introducing errors in the findings of this experiment as a result of rains, it was only held on days when there was no rain and the sunshine was relatively high. The outside experiment was performed from 11:00 A.M. to 2:00 P.M. each day when the solar radiation was stable and at its maximum or peak value in Ghana. The mild steel plate was held horizontally on a 7 ft (about 2.2 m) high horizontal board platform in an open space. The mild steel plate in the experimental setup was illuminated with solar radiation. The solar energy is intercepted by the mild steel plate which gets hot and consequently transfers its heat into the asbestos through conduction at a very low rate. In this experiment, it is assumed that there is no heat generation and the plywood thermally insulates the setup from heat loss and acts as a boundary for the experiment at both the sides and the bottom. The metal plate acts as a special heat exchanger, with a little of its sensible heat conducted into the asbestos material and the rest of the heat transferred to the environment by convection.
To estimate the amount of heat transferred into the convective atmosphere, an energy balance is applied across the system (Figure 1). Figure 1(a) is the schematic diagram of the experimental setup while Figure 1(b) shows the plate geometry whose heat transfer coefficient is to be determined under outdoor conditions. Figure 1(c) depicts the pictorial view of the setup. The temperatures are taken between the interfacial boundaries (i.e., mild steel metal and asbestos and asbestos and plywood). They are denoted by
2.3. Energy Balance for Estimating the Heat Transfer Coefficient
Using the experimental setup shown in Figure 1, the amount of energy absorbed from the heat source by the plate is expressed in Equation (1). The heat released by the sun is the algebraic sum of the heat absorbed by the plate, heat radiated from the plate surface to the sky, heat conducted by the asbestos material, and the heat transferred from the plate to the environment through convection:
The incident thermal energy absorbed by the mild steel plate is given by
The amount of heat conducted from the mild steel plate to the asbestos board is given by
Considering that the metal plate is enveloped by a large surface (i.e., the sky), the radiative heat transfer is given as
The amount of sensible heat absorbed by the mild steel plate to raise its temperature is given by
The convective heat transfer into the atmosphere can be estimated using
When Equations (2) through (3) to (7) are combined to yield Equation (8),
The relations for the constants in Equation (8) are given in
2.4. Uncertainty Analysis
Estimation of uncertainty from the measurement of
The error in the estimation of
Similarly, the errors in heat absorbed and conducted in the mild steel plate are obtained from
The error involved in the radiation is also expressed in
The errors found in the experiment are listed in Table 2.
Table 2
Instrumentation errors.
Quantity | Symbol | Error |
Metal plate thickness | ||
Metal plate temperatures | ( | 0.1°C |
Time | 1 s | |
Insulator conduction coefficient | 0.002 W/m·K | |
Insulator thickness | ||
Ambient temperature | 0.1°C |
3. Results and Discussion
The results obtained from the experiment conducted by this study are discussed here. The discussion was done based on both pictorial and numerical results which portrayed the trends observed in the experiment.
3.1. Weather and Experimental Conditions
The period used for the experiment spanned March to August, and in Ghana, it is the period when the rain begins to fall with consistency (the month of March) and when the frequency of the annual rainfall begins to dwindle for most of the year (the month of August) as established by the climatic data of Ghana (courtesy of Ghana Meteorological Authority). The months of April through May to July were the most humid months of the period used for this study; thus, the weather condition for this experiment can be described as rainy and humid. Since the experiment was done outdoor, the weather conditions were the same for the experiment. However, in terms of the physical conditions created by the experimental setup, the fluid flow condition for the experiment can be said to be transition flow due to the relatively low and the large intermittent air speeds created by the surrounding trees at the site and the obstruction caused by the experimental setup itself.
3.2. Thermal Analysis and Heat Transfer Coefficient
The heat transfer terms were calculated using the average values measured in every 10 minutes. Figure 2 shows that the radiation received by the mild steel plate is almost stable. The slight variation in the radiation intensity can be attributed to the attenuation of the solar radiation. To reduce this effect, the experiment was planned and held during a period when the sun peaks in most parts of Ghana. The sun peak hours in which this experiment was conducted start from 11:00 A.M. and end at 2:00 P.M. The temperature variations for the mild steel plate/asbestos and asbestos/plywood interfaces are shown in Figure 3.
[figure omitted; refer to PDF]
[figures omitted; refer to PDF]
From Figure 3(a), the mild steel plate temperature and the interfacial plate/asbestos temperature curves coincide. These temperature-time curves are seen as the first curve on top of Figure 3(a). This phenomenon can be explained by the fact that the plate is very thin (0.1 cm) and has a very good conductive coefficient which does not create room for any heat storage.
It is assumed that the particles of the mild steel plate transfer its thermal energy to adjacent molecules as quickly as possible without any initial storage of heat before permitting transfer of heat from the molecules closer to the heat source to those farther away from the source of heat and other bodies. The second temperature curve from the top as obtained from the interfacial asbestos/plywood shows that there is resistance to the flow of heat through the asbestos board. This resistance to heat transfer offered by the asbestos creates difference in temperature or heat gradients. The fall in the initial values of the mild steel plate and the two interfacial temperatures is due to sensible heating of the asbestos board. The temperature curves are all seen to rise with time because the heating of the asbestos board by the sun was not obstructed in the experiment or the setup was allowed to receive incremental heat for the whole span of the experiment.
The mild steel plate surface was treated with a matt black paint to increase its absorptivity. This treatment positively affected the amount of heat absorbed by the plate as it absorbed more heat from the incident radiation.
The last or the third curve from the top (also in Figure 3(a)) represents the ambient temperature which was found to be the lowest recorded temperature in the experiment.
Figure 3(b) shows the heat transfer mechanisms, i.e., the heat absorbed by plate, the heat conducted, and the heat radiated as discussed in Method.
The uppermost curve represents the incident solar radiation on the plate and is followed by the heat absorbed by the plate. The difference in the two curves is due to the nature of the surface. A reflective or mirror surface reflects a large amount of the heat radiation while a matt black or dull surface absorbs more. The mild steel plate with a matt black surface had an absorptivity of 0.9 making it to approach a black body surface, thus absorbing a relatively maximum amount of the incident radiation. Another notable thing is the flow; i.e., there is no time lag between the two. The heat released to the asbestos by the mild steel plate is made possible by conduction. This thermal energy is transferred to the asbestos board as a sensible heat by increasing its temperature. The third curve shows the heat flux through the asbestos board. The heat flux curve is seen falling suddenly at the beginning, and this is due to the sensible heating that takes place before the heat flux through the asbestos board begins. Immediately after the sensible heating of the asbestos board, its temperature starts to rise and this can be seen in Figure 3(b). The last two curves show the heat flux radiated by plate and the heat that caused the sensible heating of the mild steel plate, respectively. The small values of these heat transfers are as a result of the surface treatment and the thickness of the mild steel plate. The thermal conductivity of asbestos, an insulator, is obviously lower than that of a conductor (mild steel plate), hence the great difference in the heat flux through the plate and the asbestos.
The heat transfer coefficients were also estimated for every minute from Equation (8). The heat transfer coefficients are dependent on the air speed. Higher air speed results in higher heat transfer coefficient values whereas lower values of air speed resulted in smaller coefficients.
The erratic changes in the air speeds affected the readings obtained, and because of this, the heat transfer coefficient values were estimated with these effects in mind. Astronomical temperature values above 60°C were occasionally attained by the mild steel plate as a result of the winds created by trees around the study area. The location is a forest zone with intermittent wind speeds that can go as high as 7 m/s. From [4, 11, 12], the coefficients range from 0 to 30 W/m2·K, and it provided some basis for the evaluation of the heat transfer coefficient obtained by this study. During the evaluation, values above 40 W/m2·K were excluded from the data and the rest were used for the analysis. 2% of the values from 201 data points were masked out leaving only 197 data points which means that the values excluded did not really have an effect on the results. A plot of heat transfer coefficients against air speed is shown in Figure 4. This figure depicts linear (Figure 4(a)) and exponential regression (Figure 4(b)) plots which were used to draw curves of the best fit. For both cases, the regression
[figures omitted; refer to PDF]
The plotted points are more scattered and concentrated at low air speed which means that the area is dominated by small air speeds below 2 m/s. From the graph, it can be seen that larger wind speeds correspond to larger coefficients and there is a positive relationship between the variables, hence the positive gradient of the curve. The linear regression of the points yielded Equation (16) whereas the exponential regression yielded Equation (17).
The linear regression had a better fitting than the exponential regression; therefore, the linear regression (Equation (16)) was used.
The positive gradient of 6.96 in the linear equation shows that the margin of increment of the heat transfer coefficient is larger as compared to values such as 5.7, 3.87, and 2.8 [5, 11, 12] which are mostly wind tunnel results. Values like 8.55 and 6.5 from [4, 10], respectively, were obtained from outdoor experimental setups. The peculiarity of the high gradients for the outdoor experimental setups makes them have higher coefficients over the indoor studios. One notable observation is the intercept of 5.23 which shows that there is always a possibility of heat transfer even at times when there are no air flows/winds.
3.3. Error Estimation from Instrumentation
When instruments are used to take measurements, there is the possibility of reading errors due to instrument limitations in measurement processes. To evaluate the extent of this error in the actual values of this study, Equations (16) through (17) to (18) were used to estimate the uncertainty introduced. An average of 14% instrumentation error was recorded for the measurements taken during this experiment. An error of +14% is recommended for experiments whose processes are mostly automated. From the errors, it happens that the maximum error of uncertainty was recorded from the amount of heat stored in the plate, and this can be attributed to the difficulties in the measurement of the plate temperature as it loses heat to the surroundings under unpredictable conditions.
3.4. Comparison of the Present Work with Previous Works
The authors whose works were reviewed by this study all used linear regressions for their experimental analysis that is why the researchers of this study were motivated to choose the regression method for this study. This decision informed the authors of this paper to compare the difference between the empirical equations obtained by this present work with those obtained by previous works.
Complications occurred as a result of the different experimental setups (indoor and outdoor setups as adopted by [4, 5, 10–12]). Some of the experiments were held in wind tunnels kept in studios while others were done outdoors. One other factor which introduced some complications and for that matter necessitated the comparison of this present work to previous ones is the size of the plate. This particular comparison was done by normalising previous works with a relation provided by [9]. The relation is given in Equation (18) which satisfies the present model and the model presented by [9].
For the sake of analysing the various curves of the models displayed in Figure 5 (involving present and previous models), the average wind speed obtained by this research (1.6 m/s) was used as the reference speed for comparison of the various models. The models compared to this study are those developed by [3–5, 10–12].
[figure omitted; refer to PDF]
The presentation of the coefficients in ascending order is as follows: [4, 5, 9–12], present work, and [3].
The order shows that wind tunnel models have lower coefficient values while the outdoor setup models have larger values.
The bottom curve [12] shows a great disparity in value as compared to the rest. This phenomenon can be attributed to the fact that disturbances from the surroundings were absent in the experiment (wind tunnel). In indoor studio setups, the experimental variables are completely held under quasi-equilibrium conditions throughout the experiment especially in the case of convective air. In the case of outdoor experimental setups, disturbances are felt and are unfortunate and unpredictable. For example, trees around redirect or shield the wind at the same time. This unpredictable wind surges create whirls around the plates and consequently increase the coefficient values and the temperature gradient thus leading to greater heat transfer from the plate. It can then be deduced from the values that lower disturbances create small coefficients while bigger disturbances create larger coefficients.
Another notable observation is that analytical equations and wind tunnel setups are unable to model all the environmental details including unsteady outside air flow conditions, difference in levels of turbulence, and the magnitudes and dynamics of air flow (wind). Normally, air flow in wind tunnels and analytical experiments are modelled under steady conditions while outdoor experiments are modelled under unsteady and unidirectional conditions. The unsteady nature of wind creates an unsteady boundary layer over outdoor experiments leading to the large difference in values between the two regimes (outdoor and indoor experiments).
The large differences in values recorded can also be accounted for by the flow development around the borders of the mild steel plate. The regime of flow development in unsteady and turbulent outdoor environment is nonexistent while that of the indoor experimental environment is partially/fully developed. The flow profile of outdoor experimental setups for heat transfer is usually undeveloped because the
The change in the trend of the values of air speed for the indoor studio as depicted by [3] is higher than that of the outdoor values obtained by the same study (which is usually not the case) as well as this study. These values are as a result of the larger industrial fan used for indoor experiments and the scale of the experiment. Large fans create large swirls around the plate which affect the development of the boundary layer and the flow profile, hence the large heat transfer coefficient values obtained by [3].
It can therefore be concluded that heat transfer coefficients for indoor experiments should not be used for outdoor experiments without adequate justification.
4. Conclusion
Solar thermal collectors are special heat exchangers that absorb and transfer heat energy to other bodies. Bodies illuminated by radiation absorb and transfer part of their absorbed radiation through convection, conduction, and radiation. Systems exposed to outdoor environmental conditions undergo heat transfer or thermal exchange as a result of wind-induced convection. This heat exchange between the thermal system and its environments leads to losses that have direct influence on the performance or efficiency of the system. The performance of thermal systems is normally represented by its heat loss coefficient to simplify and combine the effect of both radiation and convection modes of heat transfer.
One complicated phenomenon of heat transfer is the fact that heat loss by combination of radiation and convection is environmentally dependent. An empirical model was created outdoor to establish a relation between
Acknowledgments
We wish to express our profound gratitude to all the 2019 final year engineering students, both undergraduate and postgraduate students, of the University of Energy and Natural Resources, Sunyani, Ghana, who helped in the construction of the electronic device used by this study for data collection. Special thanks go to Mr. Eric Anokye Gyimah, a former student of our university, who did his voluntary service in the Mechanical and Manufacturing Engineering Department of the university.
Glossary
Nomenclature
[1] R. D. Clear, L. Gartland, F. C. Winkelmann, "An empirical correlation for the outside convective air-film coefficient for horizontal roofs," Energy and Buildings, vol. 35 no. 8, pp. 797-811, DOI: 10.1016/S0378-7788(02)00240-2, 2003.
[2] P. Karava, C. M. Jubayer, E. Savory, "Numerical modelling of forced convective heat transfer from the inclined windward roof of an isolated low-rise building with application to photovoltaic/thermal systems," Applied Thermal Engineering, vol. 31 no. 11-12, pp. 1950-1963, DOI: 10.1016/j.applthermaleng.2011.02.042, 2011.
[3] S. Kumar, V. B. Sharma, T. C. Kandpal, S. C. Mullick, "Wind induced heat losses from outer cover of solar collectors," Renewable Energy, vol. 10 no. 4, pp. 613-616, DOI: 10.1016/S0960-1481(96)00031-6, 1997.
[4] F. L. Test, R. C. Lessmann, A. Johary, "Heat transfer during wind flow over rectangular bodies in the natural environment," Transactions of the ASME Journal of Heat Transfer, vol. 103 no. 2, pp. 262-267, DOI: 10.1115/1.3244451, 1981.
[5] S. Kumar, S. C. Mullick, "Wind heat transfer coefficient in solar collectors in outdoor conditions," Solar Energy, vol. 84 no. 6, pp. 956-963, DOI: 10.1016/j.solener.2010.03.003, 2010.
[6] J. L. A. Francey, J. Paraioannou, "Wind-related heat losses of a flat-plate collector," Solar Energy, vol. 35 no. 1, pp. 15-19, DOI: 10.1016/0038-092X(85)90032-5, 1985.
[7] S. Y. Wu, H. Zhang, L. Xiao, Y. Qiu, "Experimental investigation on convection heat transfer characteristics of flat plate under environmental wind condition," International Journal of Green Energy, vol. 14 no. 3, pp. 317-329, DOI: 10.1080/15435075.2016.1259164, 2017.
[8] R. J. Kind, D. H. Gladstone, A. D. Moizer, "Convective heat losses from flat-plate solar collectors in turbulent winds," Journal of Solar energy engineering, vol. 105 no. 1, pp. 80-85, DOI: 10.1115/1.3266350, 1983.
[9] S. C. Mullick, S. Kumar, B. K. Chourasia, "Wind induced heat transfer coefficient from flat horizontal surfaces exposed to solar radiation," Energy Sustainability, vol. 47977, pp. 1131-1137, 2007.
[10] S. Sharples, P. S. Charlesworth, "Full-scale measurements of wind-induced convective heat transfer from a roof- mounted flat plate solar collector," Solar Energy, vol. 62 no. 2, pp. 69-77, DOI: 10.1016/S0038-092X(97)00119-9, 1998.
[11] W. H. McAdams, Heat Transmission, 1954.
[12] J. H. Wattmuff, W. W. S. Charters, D. Proctor, "Solar and wind induced external coefficients for solar collectors," Internationale Revue d’Heliotechnique, vol. 2, 1977.
[13] E. Sartori, "Convection coefficient equations for forced air flow over flat surfaces," Solar Energy, vol. 80 no. 9, pp. 1063-1071, DOI: 10.1016/j.solener.2005.11.001, 2006.
[14] E. M. Sparrow, J. W. Ramsey, E. A. Mass, "Effect of finite width on heat transfer and fluid flow about an inclined rectangular plate," Journal of Heat Transfer, vol. 101 no. 2, pp. 199-204, DOI: 10.1115/1.3450946, 1979.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Copyright © 2021 Felix Uba et al. This is an open access article distributed under the Creative Commons Attribution License (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License. https://creativecommons.org/licenses/by/4.0/
Abstract
This research presents a study on the heat transfer coefficient for an unglazed solar plate collector in an unsteady humid outdoor environment. The purpose for undertaking this research is to investigate the correlation between the heat transfer coefficient and air speed and also verify whether heat transfer from unglazed solar thermal collectors under outdoor conditions can be experimentally determined using a particular mathematical relationship for different locations. In estimating the heat transfer coefficient for an unglazed solar plate in an unsteady humid outdoor condition, an experiment was held using an outdoor setup that measured temperatures, wind speeds, and solar radiations from 11:00 A.M. to 2:00 P.M. The solar plate collector was placed on a flat bed of height 2.2 m and a collection area of 0743 m2. An average temperature of 45°C was recorded for a mild steel plate collector which was initially exposed to an ambient temperature which ranges from 25°C to 32°C. The interfacial temperature between the plate and an asbestos board ranges from 42°C to 52°C, and that of the asbestos and a plywood is 40°C to 46°C. The specific heat capacity of the mild steel plate and the asbestos board used for the construction of the experimental setup are 25.00 kJ/kg and 950.00 kJ/kg, respectively, while the thermal conductivity of these materials is 0.46 W/m·K and 0.25 W/m·K, respectively. The novelty of this work is the use of such a study to generate empirical equations for Ghana and to produce representative equations for determining the heat transfer coefficient for solar plate collectors in unsteady humid outdoor conditions in West Africa. This work is expected to contribute data alongside similar works done for different areas to help propose empirical equations for estimating global and not site-specific heat transfer coefficients.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Details

1 Department of Mechanical and Manufacturing Engineering, University of Energy and Natural Resources, Sunyani, Ghana
2 Department of Mechanical Engineering, Kwame Nkrumah University of Science and Technology, Kumasi, Ghana